Outline
Echocardiographic Assessment of Myocardial Performance Index After Complete Surgical Correction of Tetralogy of Fallot
Authors
Abstract
Cardiac function may change following complete surgical correction of
Tetralogy of Fallot (TOF) and measures that can assess these changes are either invasive
or very expensive.
Objectives: This study aim was to investigate the use of Doppler echocardiography as
a simple, inexpensive and reproducible method for assessment of cardiac function
References
- 1.Full Text Available is PDF.
Copyright
© 2011, Multidisciplinary Cardiovascular Annals. This open-access article is available under the Creative Commons Attribution-NonCommercial 4.0 (CC BY-NC 4.0) International License (https://creativecommons.org/licenses/by-nc/4.0/), which allows for the copying and redistribution of the material only for noncommercial purposes, provided that the original work is properly cited.
Similar Articles
Correlation of Fragmented QRS with Right Ventricular Indexes and Fibrosis in Patients with Repaired Tetralogy of Fallot, by Cardiac Magnetic Resonance Imaging
Alizadeh Sani Z, Vasheghani farahani A, Khajali Z, Jamshidi M, Hesami M, et al. Correlation of Fragmented QRS with Right Ventricular Indexes and Fibrosis in Patients with Repaired Tetralogy of Fallot, by Cardiac Magnetic Resonance Imaging. Int Cardiovasc Res J. 2017;11(3):e10239. doi:
Impact of Basal Plane Selection on the Evaluation of Cardiac Performance Parameters with Cardiac Magnetic Resonance Imaging in Patients with Corrected Tetralogy of Fallot: A Systematic Approach
Marterer R, Tschauner S, Grangl G, Kalmar P, Sorantin E. Impact of Basal Plane Selection on the Evaluation of Cardiac Performance Parameters with Cardiac Magnetic Resonance Imaging in Patients with Corrected Tetralogy of Fallot: A Systematic Approach. I J Radiol. 2019;16(1):e74219. doi: https://doi.org/10.5812/iranjradiol.74219
Comparison and Validity of Fragmented QRS (fQRS) Against Cardiac Magnetic Resonance (CMR) in Predicting Right Heart Function in Tetralogy of Fallot Patients After Reconstructive Surgery
Zargaran B, Naghibi Sistani M, Akhavein F, Mottaghi Moghaddam Shahri H. Comparison and Validity of Fragmented QRS (fQRS) Against Cardiac Magnetic Resonance (CMR) in Predicting Right Heart Function in Tetralogy of Fallot Patients After Reconstructive Surgery. J Compr Ped. 2023;14(4):e136258. doi: https://doi.org/10.5812/jcp-136258
Correlation between QRS Duration, Pulmonary Insufficiency and Right Ventricle Performance in Totally Corrected Tetralogy of Fallot
Sayadpour Zanjani K, Tanasan A, Kocharian A, K. Payravian F, Torabian S. Correlation between QRS Duration, Pulmonary Insufficiency and Right Ventricle Performance in Totally Corrected Tetralogy of Fallot. Inn J Pediatr. 2013;23(5):. doi:
Prosthetic valve in the pulmonary position, a late complication after total correction of tetralogy of fallot, a new controversial topic in cardiac surgery
Baghaee Tehrani R, Raisi K, Rostami A. Prosthetic valve in the pulmonary position, a late complication after total correction of tetralogy of fallot, a new controversial topic in cardiac surgery. Multidiscip Cardio Annal. 2008;2(2):e8711. doi:
- Scopus by DOI: 0
Last Update: 0 months ago
- Scopus by Title: 0
Last Update: 0 months ago
- Scopus by Title (Ref): 0
Last Update: 0 months ago
- CrossRef: 0
Last Update: 1 day ago