In-silico Methods for Estimating the Risk of Radiation-induced Cataracts in Nuclear Medicine Technicians

Author(s):
Etesam MalekzadehEtesam Malekzadeh1,*
1Abadan University of Medical Sciences, Abadan, Iran

Comprehensive Health and Biomedical Studies:Vol. 1, issue 4; e148451
Published online:May 25, 2024
Article type:Letter
Received:May 01, 2024
Accepted:May 06, 2024
How to Cite:Malekzadeh E. In-silico Methods for Estimating the Risk of Radiation-induced Cataracts in Nuclear Medicine Technicians. Compr Health Biomed Stud. 2023;1(4):e148451. doi: https://doi.org/10.5812/chbs-148451

Dear Editor,
Here is the revised text, maintaining all numbers, references, and the overall meaning:
Radiation exposure from gamma-emitting radionuclides, such as Tc-99m, to the eye lenses of nuclear medicine technicians during the radiopharmaceutical preparation and injection process may cause severe deterministic radiation effects, such as cataracts, which have a dose threshold of 0.5 Gy and an annual effective dose limit of 20 mSv averaged over 5 years (1). The risk of cataract incidence has a direct relationship with the amount of radiation absorbed dose, which is defined as absorbed energy per unit mass of the irradiated object (2). Therefore, estimating the absorbed dose to the eye lenses is crucial for nuclear medicine technicians. There are several experimental and in-silico methods for dose estimation in nuclear medicine, such as thermoluminescence dosimetry (TLD) and Monte Carlo (MC) simulation (3, 4). Experimental methods have several limitations, for example, easy access to dedicated dosimeters, especially in least-developed countries, implantation of dosimeters in eye lenses, and cost. On the other hand, validated in-silico methods can measure the exact dose to the eye lenses, provide easy access to MC codes, and allow for dose assessment from different types of radiation, modeling radiation interaction in real geometries using anthropomorphic mathematical phantoms (3, 5). MC simulation and the MIRD (Medical Internal Radiation Dosimetry) approach are important in-silico dose estimation methods in nuclear medicine. MC simulation is a numerical method based on statistical equations for solving geometrically complicated problems. Due to the stochastic nature of radiation transport in matter, MC simulation is the most accurate in-silico method in radiation dosimetry (5). The main limitation of MC codes is their long computation time. However, the MIRD approach is a deterministic method in which mathematical equations are used for dose calculation. Compared to the MC method, the MIRD approach is fast, but its accuracy is less than that of the MC method. In conclusion, considering different radiation exposure conditions for a technician in a nuclear medicine center, validated in-silico codes, instead of experimental methods, can be used for accurate modeling of radiation interaction in the human body, such as eye lenses.

Footnotes

References

  • 1.
    Boal TJ, Pinak M. Dose limits to the lens of the eye: International Basic Safety Standards and related guidance. Ann ICRP. 2015;44(1 Suppl):112-7. [PubMed ID: 25816264]. https://doi.org/10.1177/0146645314562321.
  • 2.
    Hall EJ, Giaccia AJ. Radiobiology for the Radiologist (Vol. 6): Philadelphia. PA: Lippincott Williams & Wilkins.[Google Scholar]; 2006.
  • 3.
    Morhrasi P, Jumpee C, Charoenphun P, Chuamsaamarkkee K%JOMI, Radiation Sciences. Estimation of Occupational Eye Lens Dose in Nuclear Medicine: A Monte Carlo Study. J Medical Imaging and Radiation Sci. 2022;53(4). S29.
  • 4.
    Wrzesien M, Krolicki L, Albiniak L, Olszewski J. Is eye lens dosimetry needed in nuclear medicine? J Radiol Prot. 2018;38(2):763-74. [PubMed ID: 29667600]. https://doi.org/10.1088/1361-6498/aabef5.
  • 5.
    Sarrut D, Bardies M, Boussion N, Freud N, Jan S, Letang JM, et al. A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications. Med Phys. 2014;41(6):64301. [PubMed ID: 24877844]. https://doi.org/10.1118/1.4871617.

Similar Articles

30
Sep
2006

The Estimation of Radiation Effective Dose from Diagnostic Medical Procedures in General Population of Northern Iran

Ali Shabestani Monfared,
R Abdi

Shabestani Monfared A, Abdi R. The Estimation of Radiation Effective Dose from Diagnostic Medical Procedures in General Population of Northern Iran. I J Radiol. 2006;3(3):e79019. doi:

17
Mar
2009

Knowledge Of Medical Students On Hazards Of Ionizing Radiation

MR Tavakoli,
F SeilanianToosi,
SA Saadatjou

Tavakoli M, SeilanianToosi F, Saadatjou S. Knowledge Of Medical Students On Hazards Of Ionizing Radiation. J Med Edu. 2003;3(1):e105011. doi: https://doi.org/10.22037/jme.v3i1.866

12
Jun
2018
Common Diagnostic Radiology Procedures, Academic Radiology

Cumulative Radiation Dose and Cancer Risk Estimation in Common Diagnostic Radiology Procedures

Safoora Nikzad,
Maryam Pourkaveh,
Naghi Jabbari Vesal,
Farideh Gharekhanloo

Nikzad S, Pourkaveh M, Jabbari Vesal N, Gharekhanloo F. Cumulative Radiation Dose and Cancer Risk Estimation in Common Diagnostic Radiology Procedures. I J Radiol. 2018;15(3):e60955. doi: https://doi.org/10.5812/iranjradiol.60955

28
Dec
2020
Ann Mil Health Sci Res

An Investigation of Natural Background Radiation and Health Risk Assessment in Kohgiluyeh and Boyer-Ahmad Province, Iran

Mahmoud Bagheri,
Mohammad Reza Fouladi,
Razzagh Abedi-Firouzjah

Bagheri M, Fouladi MR, Abedi-Firouzjah R. An Investigation of Natural Background Radiation and Health Risk Assessment in Kohgiluyeh and Boyer-Ahmad Province, Iran. Ann Mil Health Sci Res. 2020;18(4):e106801. doi: https://doi.org/10.5812/amh.106801

30
Dec
2005

Pediatric Radiation Exposure from Diagnostic Nuclear Medicine Examinations in Tehran

Isa Neshandar asli,
F Tabeie

Neshandar asli I, Tabeie F. Pediatric Radiation Exposure from Diagnostic Nuclear Medicine Examinations in Tehran. I J Radiol. 2005;3(1):e79078. doi:


Crossmark
Crossmark
Checking
Share on
Cited by
Metrics

Ordering Reprints

Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC