How to extract a losing intra-aortic balloon pump guide wire

Authors

Manouchehr Hekmat1, hamid Ghaderi2,*, Seyedeh Adeleh Mirjafari3, Mehran Shahzamani2, Gholamreza Masoumi4
1Department of Cardiovascular Surgery, Shahid Modarres Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
2Department of Cardiovascular Surgery, Chamran Heart Center Hospital, Isfahan University of Medical sciences, Isfahan, Iran
3Tehran University of Medical Sciences, Tehran, Iran
4Department of Cardiac Anesthesiology, Chamran Heart Center Hospital, Isfahan University of Medical sciences, Isfahan, Iran
*Corresponding Author: Corresponding author:Department of Cardiovascular Surgery, Chamran Heart Center Hospital, Isfahan University of Medical sciences, Isfahan, Iran. E-mail: Email: hghaderi@razi.tums.ac.ir

International Journal of Cardiovascular Practice:Vol. 3, issue 1; 18-19
Published online:Jan 21, 2018
Article type:Case Report
Received:Dec 19, 2017
Accepted:Jan 02, 2018
How to Cite:Hekmat M, Ghaderi H, Mirjafari SA, Shahzamani M, Masoumi G. How to extract a losing intra-aortic balloon pump guide wire. Int J Cardiovasc Pract. 2018;3(1):e130259. doi: https://doi.org/10.21859/ijcp-03105

Abstract

Guidewire loss is a serious complication that in case of a complete wire loss could cause death in about 20% of cases. Although it is essential to retrieve an intravenous foreign body as soon as possible, there are only a few recommendations regarding the removal of an intra-arterial foreign body. This study reports on a rare complication of guidewire loss during the insertion of an Intra-Aortic Balloon Pump (IABP), which has not yet been reported in the literature. The approach to this problem has been described, including the extraction time and the technique.

Highlights

Fulltext

Full-text is available in PDF file.

Copyright

© 2018, International Journal of Cardiovascular Practice. This open-access article is available under the Creative Commons Attribution-NonCommercial 4.0 (CC BY-NC 4.0) International License (https://creativecommons.org/licenses/by-nc/4.0/), which allows for the copying and redistribution of the material only for noncommercial purposes, provided that the original work is properly cited.

Similar Articles

30
Jun
2010
Percutaneous Retrieval of a Dislodged Guide Wire by Dormia Basket in a 98-year-old Patient, Still a Safe and Feasible Approach

Percutaneous Retrieval of a Dislodged Guide Wire by Dormia Basket in a 98-year-old Patient, Still a Safe and Feasible Approach

N Zirak,
Gh Soltani,
A Maraghe moghaddam,
MH Nezafati,
M Abbasi,
H Javan

Zirak N, Soltani G, Maraghe moghaddam A, Nezafati M, Abbasi M, et al. Percutaneous Retrieval of a Dislodged Guide Wire by Dormia Basket in a 98-year-old Patient, Still a Safe and Feasible Approach. Int Cardiovasc Res J. 2010;4(2):e65020. doi:

7
Mar
2008
Factors influencing vascular complications of Intra-aortic balloon pump

Factors influencing vascular complications of Intra-aortic balloon pump

Mohammad Sadegh Pour Abbasi Sadegh Pour Abbasi,
Shahyad Shahyad Salehi

Sadegh Pour Abbasi MSPA, Shahyad Salehi S. Factors influencing vascular complications of Intra-aortic balloon pump. Multidiscip Cardio Annal. 2008;2(2):e8706. doi:

13
Feb
2016
Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization

Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization

Agrawal Amit,
Shrivastava Jyotsna,
Vinay Kumar Kasyap

Amit A, Jyotsna S, Kumar Kasyap V. Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization. J Compr Ped. 2016;7(1):e33238. doi: https://doi.org/10.17795/compreped-33238

30
Mar
2021
The Factors Predicting Retroperitoneal Hematoma Following Intra- Aortic Balloon Pump Insertion Site Injury

The Factors Predicting Retroperitoneal Hematoma Following Intra- Aortic Balloon Pump Insertion Site Injury

Feridoun Sabzi,
Mohammad Rouzbahani,
Atefeh Asadmobini,
Reza Heidari Moghaddam,
Aghigh Heydari

Sabzi F, Rouzbahani M, Asadmobini A, Heidari Moghaddam R, Heydari A. The Factors Predicting Retroperitoneal Hematoma Following Intra- Aortic Balloon Pump Insertion Site Injury. Int Cardiovasc Res J. 2021;15(1):e101955. doi:

1
Mar
2017
Guide Wire Entrapment in Mitral Subvalvular Apparatus during Left Lateral Accessory Pathway Ablation: A Case Report

Guide Wire Entrapment in Mitral Subvalvular Apparatus during Left Lateral Accessory Pathway Ablation: A Case Report

Mohammad Vahid Jorat,
Mohammad hossein Nikoo,
Maryam Tahamtan

Jorat MV, Nikoo MH, Tahamtan M. Guide Wire Entrapment in Mitral Subvalvular Apparatus during Left Lateral Accessory Pathway Ablation: A Case Report. Int Cardiovasc Res J. 2017;11(1):e10557. doi:

More by these authors

Manouchehr HekmatPubMedScholar
hamid GhaderiPubMedScholar
Seyedeh Adeleh MirjafariPubMedScholar
Mehran ShahzamaniPubMedScholar
Gholamreza MasoumiPubMedScholar
Share
Cited by
Metrics