Cover image of the article: Determining the Correlation and Accuracy of Three Methods of Measuring Neonatal Bilirubin Concentration

Image Credit:Inn J Pediatr

Determining the Correlation and Accuracy of Three Methods of Measuring Neonatal Bilirubin Concentration

Authors

Mirhadi Mussavi1, Pedram Niknafs2,*, Bahareh Bijari3
*Corresponding Author: Email: pniknaffs@yahoo.com

Innovative Journal of Pediatrics:Vol. 23, issue 3; 333-339
Published online:May 07, 2013
Article type:Research Article
Received:Jun 13, 2012
Accepted:Mar 16, 2013
How to Cite:Mussavi M, Niknafs P, Bijari B. Determining the Correlation and Accuracy of Three Methods of Measuring Neonatal Bilirubin Concentration. Inn J Pediatr. 2013;23(3):. doi:

Abstract

Objective: There are different methods for measuring bilirubin concentration; however, it is quite important for practitioners to know which method should be used in certain clinical situations. The present prospective study aimed to compare three different methods for measuring neonatal bilirubin concentrations.
Methods: All full term neonates who were either brought into emergency departments or admitted to the neonatal wards in Kerman city in 2011 were recruited (n=428). The correlation coefficients were estimated for the routine ways of bilirubin concentrations including "Capillary", "Cutaneous" and "Laboratory" methods.
Findings: Of 428 recruited neonates, 178 were female. Mean age ±SD was 178±71 hours. The correlation coefficient for "David Icterometer" vs "JM103" was 0.91, while the corresponding coefficient for "David Icterometer" vs "Capillary" was 0.96. It was also equivalent to 0.85 for correlation between "JM103" and "Capillary" methods. The David Icterometer measured an average of 2.36 mg/dl levels of bilirubin concentration compared to the JM103 method. The Capillary method showed a lower bilirubin level than the venous concentration (0.91 mg/dl on average). Compared with the "Capillary", the "JM103" measured a slightly higher level of bilirubin with an average 0.57 mg/dl.
Conclusion: Due to low difference (less than 1 mg/dl) between "JM103" and the "Capillary methods" for measurement of neonatal bilirubin concentration, these two methods could alternatively be used instead of usual laboratory method.

 

Highlights

References

  • 1.
    References are available on the PDF.

Copyright

© 2013, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

25
Mar
2020
Comparison of Serum Bilirubin Level of Neonates Under Phototherapy with Two Methods of Transcutaneous and Total Serum Bilirubin Measurement

Comparison of Serum Bilirubin Level of Neonates Under Phototherapy with Two Methods of Transcutaneous and Total Serum Bilirubin Measurement

Alireza Sadeghnia,
Nasrin Hashemian Nejad,
Shadi Noorizadeh,
Ehsan Shahrestanaki,
Zahra Jamshidi,
Hassan Salehipoor
,et al.

Sadeghnia A, Hashemian Nejad N, Noorizadeh S, Shahrestanaki E, Jamshidi Z, et al. Comparison of Serum Bilirubin Level of Neonates Under Phototherapy with Two Methods of Transcutaneous and Total Serum Bilirubin Measurement. J Compr Ped. 2020;11(2):e97482. doi: https://doi.org/10.5812/compreped.97482

16
Oct
2019
Comparison of Transcutaneous Bilirubin Measurement with Total Serum Bilirubin Levels in Term Neonates with Hyperbilirubinemia: A Descriptive-Analytical Study

Comparison of Transcutaneous Bilirubin Measurement with Total Serum Bilirubin Levels in Term Neonates with Hyperbilirubinemia: A Descriptive-Analytical Study

Alia Jalalodini,
Fereshteh Ghaljaei

Jalalodini A, Ghaljaei F. Comparison of Transcutaneous Bilirubin Measurement with Total Serum Bilirubin Levels in Term Neonates with Hyperbilirubinemia: A Descriptive-Analytical Study. J Compr Ped. 2019;10(4):e84720. doi: https://doi.org/10.5812/modernc.84720

3
Sep
2004
Comparison of change pattern of serum and transcutaneous bilirubin in hyper bilirubinemic neonates

Comparison of change pattern of serum and transcutaneous bilirubin in hyper bilirubinemic neonates

Mahmoud Imani,
Mehdi Mohammadi

Imani M, Mohammadi M. Comparison of change pattern of serum and transcutaneous bilirubin in hyper bilirubinemic neonates. Zahedan J Res Med Sci. 2004;6(3):e94994. doi:

27
Jan
2016
Evaluating the Diagnostic Value of Skin Bilirubin in Comparison with Plasma Bilirubin to Identify Hyperbilirubinemia in Healthy Babies

Evaluating the Diagnostic Value of Skin Bilirubin in Comparison with Plasma Bilirubin to Identify Hyperbilirubinemia in Healthy Babies

Navid Danaei,
Somayeh lotfpour,
Raheb Ghorbani,
Alireza Emadi,
Shamsollah Nooripour

Danaei N, lotfpour S, Ghorbani R, Emadi A, Nooripour S. Evaluating the Diagnostic Value of Skin Bilirubin in Comparison with Plasma Bilirubin to Identify Hyperbilirubinemia in Healthy Babies. Middle East J Rehabil Health Stud. 2016;3(1):e33493. doi: https://doi.org/10.17795/mejrh-33493

2
Mar
2019
Predictive value of transcutaneous bilirubinometry on third day of birth in diagnosis of hyperbilirubinemia in term and near-term neonates

Predictive value of transcutaneous bilirubinometry on third day of birth in diagnosis of hyperbilirubinemia in term and near-term neonates

Maryam Hasani,
Ashraf Ghiasi,
Masoumeh Kheirkhah,
Maryam Sabuteh,
Zahra Karimian,
Hamideh Zaheri
,et al.

Hasani M, Ghiasi A, Kheirkhah M, Sabuteh M, Karimian Z, et al. Predictive value of transcutaneous bilirubinometry on third day of birth in diagnosis of hyperbilirubinemia in term and near-term neonates. koomesh. 2019;21(1):e153032. doi:

More by these authors

Mirhadi MussaviPubMedScholar
Pedram NiknafsPubMedScholar
Bahareh BijariPubMedScholar
Share
Cited by
Metrics