Cover image of the article: An in vitro comparison of Foramatron and Raypex5 apex locator accuracy

Image Credit:J Inflamm Dis

An in vitro comparison of Foramatron and Raypex5 apex locator accuracy

Authors

H Khalilkhani, F Azmoudeh,*, F Salamat
*Corresponding Author: Email: fazmoudeh@mail.com

Journal of Inflammatory Diseases:Vol. 17, issue 1; 35-41
Published online:Jun 30, 2013
Article type:Research Article
How to Cite:Khalilkhani H, Azmoudeh F, Salamat F. An in vitro comparison of Foramatron and Raypex5 apex locator accuracy. J Inflamm Dis. 2024;17(1):e155741. doi:

Abstract

  Background: Assessment of the length of root canal is the first and the most important step of a successful root canal therapy (RCT). Although radiography is the most common technique in working length determination, it is not the technique of choice due to its limitations. Electronic apex locator has been used to solve the problem.   Objective: The purpose of this study was to compare the in vitro accuracy of two electronic apex locators Raypex5 and Foramatron in determination of working length.   Methods: This analytical study was performed in Qazvin dental school in 2005. 30 extracted single canal teeth were selected and the access cavity was prepared for them. The working length measured by two apex locators in dry and wet situation was compared to actual canal length that was determined under stereomicroscope. Data were analyzed by paired t-test.   Findings: The accuracy of Raypex5 working length determination was 86.7% and 76.7%, respectively, in dry and wet situation for a tolerance limit of 0-0.5 mm. The accuracy of Formatron working length determination was 73.4% and 63.4% and there was no statistically significant difference between the accuracy of the instruments.   Conclusion: Although the accuracy of Raypex5 in working length determination was more than Foramatron, both of them are useful as an adjunct to radiography in working length measurement.   

Highlights

Copyright

© 2024, Journal of Inflammatory Diseases. This open-access article is available under the Creative Commons Attribution-NonCommercial 4.0 (CC BY-NC 4.0) International License (https://creativecommons.org/licenses/by-nc/4.0/), which allows for the copying and redistribution of the material only for noncommercial purposes, provided that the original work is properly cited.

Similar Articles

7
Aug
2016
Performance of the Working Length Determination using Cone Beam Computed Tomography, Radiography and Electronic Apex Locator, in Comparisons to Actual Length

Performance of the Working Length Determination using Cone Beam Computed Tomography, Radiography and Electronic Apex Locator, in Comparisons to Actual Length

Cihan Yildirim,
Ali Murat Aktan,
Emrah Karataslioglu,
Fatih Aksoy,
Ozlem Isman,
Emre Culha

Yildirim C, Murat Aktan A, Karataslioglu E, Aksoy F, Isman O, et al. Performance of the Working Length Determination using Cone Beam Computed Tomography, Radiography and Electronic Apex Locator, in Comparisons to Actual Length. I J Radiol. 2017;14(1):e13468. doi: https://doi.org/10.5812/iranjradiol.31007

17
Jan
2008
Accuracy of Dentaport ZX in length determination of resorbed roots and non-resorbed roots in primary teeth

Accuracy of Dentaport ZX in length determination of resorbed roots and non-resorbed roots in primary teeth

AR Heydari,
m Shahrabi,
b Seraj

Heydari A, Shahrabi M, Seraj B. Accuracy of Dentaport ZX in length determination of resorbed roots and non-resorbed roots in primary teeth. Zahedan J Res Med Sci. 2008;10(1):e94748. doi:

28
Jun
2016
Comparison of Dentinal Crack Formation With Reciproc, Mtwo and ProTaper Root Canal Preparation Systems

Comparison of Dentinal Crack Formation With Reciproc, Mtwo and ProTaper Root Canal Preparation Systems

Kiumars Nazari Moghaddam,
Seyed Lotfoallah Derakhshan,
Mohammad Adeli,
Ehsan Hamzelouei Moghadam,
Mohadeseh Hashemzehi,
Mohammad Sadegh Nazari
,et al.

Nazari Moghaddam K, Derakhshan SL, Adeli M, Hamzelouei Moghadam E, Hashemzehi M, et al. Comparison of Dentinal Crack Formation With Reciproc, Mtwo and ProTaper Root Canal Preparation Systems. Middle East J Rehabil Health Stud. 2016;3(3):e38504. doi: https://doi.org/10.17795/mejrh-38504

24
Nov
2019
Comparative Evaluation of Dentinal Microcracks in Root Canals Prepared by Neoniti, Reciproc, and ProTaper Instruments

Comparative Evaluation of Dentinal Microcracks in Root Canals Prepared by Neoniti, Reciproc, and ProTaper Instruments

Eshagh Ali Saberi,
Narges Farhad Mollashahi,
Mahboobe Ahmadi

Saberi EA, Farhad Mollashahi N, Ahmadi M. Comparative Evaluation of Dentinal Microcracks in Root Canals Prepared by Neoniti, Reciproc, and ProTaper Instruments. Zahedan J Res Med Sci. 2020;22(1):e90772. doi: https://doi.org/10.5812/zjrms.90772

30
Jun
2011
Evaluation of the Accuracy of Panoramic Radiography in Linear Measurements of the Jaws

Evaluation of the Accuracy of Panoramic Radiography in Linear Measurements of the Jaws

S H Hoseini Zarch,
A Bagherpour,
Adineh Javadian Langaroodi,
A Ahmadian Yazdi,
A Safaei

Hoseini Zarch SH, Bagherpour A, Javadian Langaroodi A, Ahmadian Yazdi A, Safaei A. Evaluation of the Accuracy of Panoramic Radiography in Linear Measurements of the Jaws. I J Radiol. 2011;8(2):e93931. doi:

More by these authors

H KhalilkhaniPubMedScholar
F AzmoudehPubMedScholar
F SalamatPubMedScholar
Share
Cited by
Metrics