Evaluation of basic parameters of real-time diagnostic ultrasound systems

Authors

Fariborz Manteghi, AliAkbar Ashrafi, Manijheh MokhtariManijheh Mokhtari ORCID,*
*Corresponding Author: Email: mokhtarm@modares.ac.ir

Koomesh:Vol. 5, issue 1; 73-82
Published online:Feb 15, 2004
Article type:Research Article
How to Cite:Manteghi F, Ashrafi A, Mokhtari M. Evaluation of basic parameters of real-time diagnostic ultrasound systems. koomesh. 2004;5(1):e151997. doi:

Abstract

Introduction: Today, diagnostic ultrasound imaging is utilized immensely, vast utilization of this method in clinic necessitate the implementation of a quality control program for diminishing diagnostic errors. Materials and Methods: In this study, by using the test object and proposed performance protocol, Seventy nine real time ultrasound system have been evaluated in different hospitals in Tehran. The ultrasound systems were selected have evaluated randomly and evaluated in aspect of quality control essential parameters. Results: The results were compared to AAPM (American Association of Physicists in Medicine) recommended values. The data showed that of total tested equipments 20.3% in dead zone, 64.6% in depth measurements, 54.4% in horizontal measurements, 19.0% in axial resolution, 12.7% in lateral resolution, 20.2% in focusing number and 30.4% in uniformity had no performance as compared to AAPM recomended values. Conclusions: These results showed that the maximum error was related to lateral and depth measurements and least error was related to lateral resolution. The presence of these considerable errors highlighted the neccessity of performing a comprehensive quality control program routinely for real-time diagnostic ultrasound imaging equipments.

Highlights

Copyright

© 2004, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

30
Aug
2013
Assessing the Oldness and Capacity of Radiography and Ultrasound Equipment in Tehran University of Medical Sciences

Assessing the Oldness and Capacity of Radiography and Ultrasound Equipment in Tehran University of Medical Sciences

Payman Salamati,
Hossein Ghanaati,
Shahram Ghasemzadeh,
Amir Hossein Jalali

Salamati P, Ghanaati H, Ghasemzadeh S, Jalali AH. Assessing the Oldness and Capacity of Radiography and Ultrasound Equipment in Tehran University of Medical Sciences. I J Radiol. 2013;10(3):179-181. doi: https://doi.org/10.5812/iranjradiol.6835

31
Jul
2022
Bedside Point-of-Care Ultrasonography in Anesthesiology and Pain Management: A New Trend in Iran: A Narrative Review

Bedside Point-of-Care Ultrasonography in Anesthesiology and Pain Management: A New Trend in Iran: A Narrative Review

Reza Aminnejad,
Saeid Safari,
Aidin Zeinaly

Aminnejad R, Safari S, Zeinaly A. Bedside Point-of-Care Ultrasonography in Anesthesiology and Pain Management: A New Trend in Iran: A Narrative Review. Interv Pain Med Neuromod. 2022;2(1):e123157. doi: https://doi.org/10.5812/ipmn-123157

27
Apr
2025
Enhancing Cardiopulmonary Resuscitation: A Hemodynamic Approach Using Doppler Ultrasound and Echocardiography

Enhancing Cardiopulmonary Resuscitation: A Hemodynamic Approach Using Doppler Ultrasound and Echocardiography

Seyed Mohsen Afkhami,
Mahdi Arzani Shams Abadi,
Mohammad Reza Azimi Aval,
Ali Omrani Nava,
Maryam Masaeli,
Ebrahim Karimi
,et al.

Afkhami SM, Arzani Shams Abadi M, Azimi Aval MR, Omrani Nava A, Masaeli M, et al. Enhancing Cardiopulmonary Resuscitation: A Hemodynamic Approach Using Doppler Ultrasound and Echocardiography. Ann Mil Health Sci Res. 2025;23(2):e160160. doi: https://doi.org/10.5812/amh-160160

27
Aug
2019
Reliability Studies of Different Readers Using Computer Aided Diagnosis System in Ultrasound for Determining Identical Lesions in a Breast Phantom

Reliability Studies of Different Readers Using Computer Aided Diagnosis System in Ultrasound for Determining Identical Lesions in a Breast Phantom

Nari Choi,
Bong Joo Kang,
Na Young Jung,
Sung Hun Kim,
Jung Min Lee,
Ga Eun Park

Choi N, Kang BJ, Jung NY, Kim SH, Lee JM, et al. Reliability Studies of Different Readers Using Computer Aided Diagnosis System in Ultrasound for Determining Identical Lesions in a Breast Phantom. I J Radiol. 2019;16(4):e86898. doi: https://doi.org/10.5812/iranjradiol.86898

More by these authors

Fariborz ManteghiPubMedScholar
AliAkbar AshrafiPubMedScholar
Manijheh MokhtariPubMedScholar
Share
Cited by
Metrics