A rapid and specific PCR–ELISA for detecting Salmonella typhi

Authors

Seyed Latif Mousavi1,*, Jafar Salimiyan1, Ahmad Karimi Rahgerdi1, Jafar Amani1, Shahram Nazarian1, Hassan Ardestani1
1Department of Biology, Institute of Basic Sciences, Imam-Hossein University, Tehran, Iran
*Corresponding Author: Faculty of Science and Technology, Imam-Hossein University, Babaee Highway, Tehran, Iran. Email:, E-mail: [email protected][email protected]

Archives of Clinical Infectious Diseases:Vol. 1, issue 3; e93386
Published online:Jul 30, 2006
Article type:Research Article
Received:May 12, 2019
Accepted:Jul 18, 2006
How to Cite:Mousavi SL, Salimiyan J, Karimi Rahgerdi A, Amani J, Nazarian S, et al. A rapid and specific PCR–ELISA for detecting Salmonella typhi. Arch Clin Infect Dis. 2006;1(3):e93386. doi:

Abstract

Background: Salmonella continues to be a major food borne pathogen for animals and humans. A sensitive and specific PCR–ELISA technique was developed to detect Salmonella typhi.

Materials and methods: The assay was based on the incorporation of digoxigenin-labeled dUTP and a biotin-labeled primers specific for rfbE gene during PCR amplification. The labeled PCR products were bound to streptoavidin-coated wells of a microtiter plate and detected by ELISA. The specificity of the PCR was determined using 4 strains of Entrobacteriaceae family including Escherichia coli, Klebsiella, Proteus, and Enterobacter and 2 strains of salmonella genus including paratyphi A and entritidis.

Results: Among all the strains, only Salmonella typhi was positive. The PCR-ELISA detecting system was able to increase the sensitivity of assay up to 100 fold, compared with a conventional PCR. The detection limit in PCR-ELISA was 2.5ρg in genomic DNA and 20 cells in direct manner per reaction. The entire procedure took about 100 minutes. For further confirmation of the test, internal biotin labeled probe was designed for rfbE gene and detected with streptavidin.

Conclusion: We have developed a rapid and simple PCR-ELISA protocol suitable for routine analysis of viable Salmonella typhi.

References

  • 1.
    The references are available in PDF file.

Copyright

© 2006, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

16
Jan
2019
PCR Assays Based on invA Gene Amplification are not Reliable for Salmonella Detection

PCR Assays Based on invA Gene Amplification are not Reliable for Salmonella Detection

Carolina Resendiz-Nava,
Yajaira Esquivel-Hernandez,
Alejandro Alcaraz-Gonzalez,
Pilar Castaneda-Serrano,
Gerardo M Nava

Resendiz-Nava C, Esquivel-Hernandez Y, Alcaraz-Gonzalez A, Castaneda-Serrano P, Nava GM. PCR Assays Based on invA Gene Amplification are not Reliable for Salmonella Detection. Jundishapur J Microbiol. 2019;12(2):e68764. doi: https://doi.org/10.5812/jjm.68764

30
Apr
2011

Detection of Salmonella strain by rapid-cycle multiplex PCR

Ali Karami,
Zeynab Ahmadi,
Zahra Safiri,
Fateme Pourali

Karami A, Ahmadi Z, Safiri Z, Pourali F. Detection of Salmonella strain by rapid-cycle multiplex PCR. Jundishapur J Microbiol. 2011;4(2):. doi:

30
Apr
2009

Simultaneous Detection of Escherichia Coli O157:H7, Toxigenic Vibrio Cholerae, and Salmonella Typhimurium by Multiplex PCR

Seyed Latif Mousavi,
Iraj Rasooli,
Shahram Nazarian,
Jafar Amani

Mousavi SL, Rasooli I, Nazarian S, Amani J. Simultaneous Detection of Escherichia Coli O157:H7, Toxigenic Vibrio Cholerae, and Salmonella Typhimurium by Multiplex PCR. Arch Clin Infect Dis. 2009;4(2):. doi:

12
May
2024
Development and Evaluation of a Multiplex Fluorescence PCR for Salmonella Virulence Genes Analysis

Development and Evaluation of a Multiplex Fluorescence PCR for Salmonella Virulence Genes Analysis

Peiyan He,
Yong Yan,
Guoying Zhu,
Ze Zhu,
Zhongwen Chen

He P, Yan Y, Zhu G, Zhu Z, Chen Z. Development and Evaluation of a Multiplex Fluorescence PCR for Salmonella Virulence Genes Analysis. Jundishapur J Microbiol. 2024;17(3):e144579. doi: https://doi.org/10.5812/jjm-144579

3
Jan
2022
Reverse Transcription Loop-Mediated Isothermal Amplification Assay with High Sensitivity to Rapid Detection of Viable Salmonella in Foods

Reverse Transcription Loop-Mediated Isothermal Amplification Assay with High Sensitivity to Rapid Detection of Viable Salmonella in Foods

Dong Chen,
Fangju Tian,
Wanyu Liu,
Jingyi Yu,
Dafeng Song

Chen D, Tian F, Liu W, Yu J, Song D. Reverse Transcription Loop-Mediated Isothermal Amplification Assay with High Sensitivity to Rapid Detection of Viable Salmonella in Foods. Jundishapur J Microbiol. 2021;14(11):e117938. doi: https://doi.org/10.5812/jjm.117938

More by these authors

Seyed Latif MousaviPubMedScholar
Jafar SalimiyanPubMedScholar
Ahmad Karimi RahgerdiPubMedScholar
Jafar AmaniPubMedScholar
Shahram NazarianPubMedScholar
Hassan ArdestaniPubMedScholar
Share
Cited by
Metrics