Background: Radiotherapy plays an important role in the management of most malignant and many benign primary central nervous system (CNS) tumors. Radiotherapy affects both tumor cells and uninvolved normal cells; so, it is important to estimate absorbed dose to organs at risk in this kind of treatment. The aim of this study was to determine the absorbed dose to chiasma, lens, optic nerve, retina, parotid, thyroid and submandibular gland in frontal lobe brain tumors radiotherapy based on treatment planning system (TPS) calculation and direct measurement on the phantom.
Methods: A head and neck phantom was constructed using natural human bone and combination of paraffin wax and Sodium Chloride (NaCl) as tissueequivalent material. Six cylinders were made of phantom material which had cavities to insert Thermoluminescent Dosimeters (TLDs) at several depths in order to measure absorbed dose to chiasma, lens, optic nerve, retina, parotid, thyroid and submandibular gland. Three routine conventional plans associated with tumors of this region and a new purposed technique were performed on the phantom and dose distribution and absorbed dose to critical organs were compared using treatment planning system (TPS) calculation and direct measurement on the phantom.
Results: Absorbed doses were measured with calibrated TLDs and are expressed in centigray (cGy). In all techniques absorbed dose to all organs except the lenses were at their tolerance dose levels and in the new purposed technique, absorbed dose to chiasma was significantly reduced.
Conclusion: Our findings showed differences in the range of 1-5% in all techniques between TPS calculation and direct measurements for all organs except submandibular glands and thyroid. Because submandibular glands and thyroid are far from primary radiation field, TLD reading in these regions although small but differs from TPS calculation which shows very smaller doses. This might be due to scattered radiation which is not well considered in the TPS. In the new technique, because the chiasma is out of the radiation field, absorbed dose was reduced significantly
Highlights
Copyright
© 2015, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
Measurement of surface dose in external radiotherapy of brain frontal lobe: A study on patient and phantom
Nazemi Gelyan H, Makhdumi Y, Nikoofar A, Hasanzadeh H. Measurement of surface dose in external radiotherapy of brain frontal lobe: A study on patient and phantom. koomesh. 2016;17(2):e151348. doi:
High-Dose-Rate 192Ir Brachytherapy Dose Verification: A Phantom Study
Nikoofar A, Hoseinpour Z, Rabi Mahdavi S, Hasanzadeh H, Rezaei Tavirani M. High-Dose-Rate 192Ir Brachytherapy Dose Verification: A Phantom Study. Int J Cancer Manag. 2015;8(3):e2330. doi: https://doi.org/10.17795/ijcp2330
Analysis of Radiation Dose and Estimation of Secondary Cancer Incidence in Organs Exposed to Radiotherapy in Breast Cancer
Hashemi N, R Mafi A, Mostaar A, Kamian S. Analysis of Radiation Dose and Estimation of Secondary Cancer Incidence in Organs Exposed to Radiotherapy in Breast Cancer. Int J Cancer Manag. 2025;18(1):e161806. doi: https://doi.org/10.5812/ijcm-161806
Depth dose of critical organs of phantom based on surface dose exposed with Dual X-ray absorptiometry: pencil beam using TLD dosimetry
Sharafi A, Mokhtari M, Mokhlesian N, Larijani B, KazemNezhad A. Depth dose of critical organs of phantom based on surface dose exposed with Dual X-ray absorptiometry: pencil beam using TLD dosimetry. koomesh. 2009;10(2):e152226. doi:
Thyroid Absorbed Dose from Brain CT Examinations in Different Age Groups of Pediatric Based on Monte Carlo Simulation
Khosravi H, Nikzad S, Karami A. Thyroid Absorbed Dose from Brain CT Examinations in Different Age Groups of Pediatric Based on Monte Carlo Simulation. Ann Mil Health Sci Res. 2024;22(1):e143512. doi: https://doi.org/10.5812/amh-143512
More by these authors
- Scopus by DOI: 0
Last Update: 1 week ago
- Scopus by Title: 11
Last Update: 1 week ago
- Scopus by Title (Ref): 11
Last Update: 1 week ago
- CrossRef: 0
Last Update: 6 hours ago
- OpenAlex: 0
Last Update: 9 hours ago
- OpenCitations: 0
Last Update: 5 days ago