Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

Author(s):
Seyed Mohsen ForoutanSeyed Mohsen Foroutan1,*, Afshin ZarghiAfshin Zarghi2, Alireza ShafaatiAlireza Shafaati2, Arash KhoddamArash Khoddam3
1Department of Pharmaceutics, School of Pharmacy, Shaheed Beheshti University of Medical Sciences, Tehran, Iran
2Department of Pharmaceutical Chemistry, School of Pharmacy, Shaheed Beheshti University of Medical Sciences, Tehran, Iran
3Noor Research and Educational Institute, Tehran, Iran
*Corresponding Author: Department of Pharmaceutics, School of Pharmacy, Shaheed Beheshti University of Medical Sciences, Tehran, Iran. Email:[email protected]

IJ Pharmaceutical Research:Vol. 5, issue 1; 37-40
Published online:Nov 20, 2010
Article type:Research Article
Received:Jan 21, 2005
Accepted:Jan 21, 2005
How to Cite:Foroutan SM, Zarghi A, Shafaati A, Khoddam A. Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma. Iran J Pharm Res. 2022;5(1):e128260. doi: https://doi.org/10.22037/ijpr.2010.650

Abstract

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150×4 mm) and a UV detector (λ= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phase. The proteins were precipitated with an acetonitrile solution containing diltiazem as internal standard and the average recovery was 93.9±3.4%. The detection limit for risperidone in plasma was 0.5 ngml-1. The calibration curve was linear over the concentration range 2-50 ngml-1. The inter-day and intra-day assay coefficients of variation were found to be less than 5%. The present validated method was successfully used for pharmacokinetic studies of risperidone in human subjects.

 

 

Copyright

© 2022, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

30
Apr
2010

High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies

Hossein Amini,
Abolhassan Ahmadiani

Amini H, Ahmadiani A. High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies. Iran J Pharm Res. 2010;9(2):e126070. doi: https://doi.org/10.22037/ijpr.2010.845

7
Sep
2013

Reversed Phase High Performance Liquid Chromatographic Method for Determination of Quetiapine Fumarate in Pharmaceutical Formulation and in Spiked Human Urine

Kanakapura B Vinay,
Hosakere D Revanasiddappa,
Nagaraju Rajendraprasad,
Pavagada J Ramesh,
Kanakapura Basavaiah

Vinay KB, Revanasiddappa HD, Rajendraprasad N, Ramesh PJ, Basavaiah K. Reversed Phase High Performance Liquid Chromatographic Method for Determination of Quetiapine Fumarate in Pharmaceutical Formulation and in Spiked Human Urine. J Rep Pharm Sci. 2013;2(2):e147746. doi:

20
Nov
2010

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

Mohsen Amini,
Mahnaz Khanavi,
Abbas Shafiee

Amini M, Khanavi M, Shafiee A. Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma. Iran J Pharm Res. 2022;3(2):e128189. doi: https://doi.org/10.22037/ijpr.2010.583

31
Mar
2013

A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin

Hamideh Sobhani,
Alireza Shafaati,
Nastaran Nafissi-Varcheh,
Reza Aboofazeli

Sobhani H, Shafaati A, Nafissi-Varcheh N, Aboofazeli R. A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin. Iran J Pharm Res. 2013;12(Suppl):e125628. doi: https://doi.org/10.22037/ijpr.2013.1274

31
Oct
2019

Simultaneous Determination of Isoniazid, Pyrazinamide and Rifampin in Human Plasma by High-performance Liquid Chromatography and UV Detection

Behnam Dasht Bozorg,
Ali Goodarzi,
Fanak Fahimi,
Payam Tabarsi,
Nahid Shahsavari,
Farzad Kobarfard
,et al.

Dasht Bozorg B, Goodarzi A, Fahimi F, Tabarsi P, Shahsavari N, et al. Simultaneous Determination of Isoniazid, Pyrazinamide and Rifampin in Human Plasma by High-performance Liquid Chromatography and UV Detection. Iran J Pharm Res. 2019;18(4):e124712. doi: https://doi.org/10.22037/ijpr.2019.1100849

Download PDF122.45 KB

Crossmark

Crossmark

Checking

Share on
Cited by
Metrics

Ordering Reprints

Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC 

Search Relations

Author(s):

Related Articles