Cover image of the article: Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

Image Credit:Iran J Pharm Res

Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

Authors

Mohammad Hossein Sorouraddin1, Ebrahim Fooladi1, Abdolhossein Naseri2, Mohammad-Reza Rashidi3,*
1Department of Analytical Chemistry, Faculty of Chemistry, Tabriz University, Tabriz, Iran
2Applied Chemistry Department, Faculty of Science, Islamic Azad University, Tabriz branch, Tabriz, Iran
3Department of Medicinal Chemistry, School of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
*Corresponding Author: Department of Medicinal Chemistry, School of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran. Email:rashidi@tbzmed.ac.ir

Iranian Journal of Pharmaceutical Research:Vol. 8, issue 3; 169-177
Published online:Nov 20, 2010
Article type:Research Article
Received:Jul 01, 2008
Accepted:Nov 01, 2008
How to Cite:Sorouraddin MH, Fooladi E, Naseri A, Rashidi M. Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase. Iran J Pharm Res. 2022;8(3):e128634. doi: https://doi.org/10.22037/ijpr.2010.807

Abstract

Attempts to obtain experimental values for the kinetic parameters of phenanthridine oxidation by guinea pig or rabbit liver aldehyde oxidase using common spectrophotometric methods have not been successful due to a lower limit of detection. In the present study, a new spectrofluorimetric assay in combination with a multivariate calibration method for enzymatic kinetic study of aldehyde oxidase activity, using phenanthridine as the substrate, has been developed and validated.

Phenanthridine and phenanthridinone binary mixtures were prepared in a dynamic linear range of 0.025-1 µM and the emission flourimetric spectra of the solutions recorded at the excitation and emission wavelengths of 236 and 320-450 nm, respectively. The optimized calibration model of partial least squares (PLS) method was applied for the simultaneous determination of the concentration of each chemical in the prediction set. The limits of detection for phenanthridine and phenanthridinone were found to be 2.13 ± 0.33 and 3.41 ± 0.34 nM (mean ± SD, n = 5), respectively. This method was then used for kinetic study of phenanthridine oxidation using guinea pig and rat hepatic aldehyde oxidase. The results were compared with those obtained from a univariate spectroscopic method.

Using this new spectrofluorimetric-multivariate calibration method, the Km value for the oxidation of phenanthridine with guinea pig and rat liver aldehyde oxidase were obtained as 0.83 ± 0.08 and 2.20 ± 0.40, µM (mean ± SD, n = 3), respectively.

Highlights

Copyright

© 2022, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

17
Jan
2017
A Spectrophotometric Method for the Determination of Aldehyde Oxidase Activity Using 3-Methyl-2- Benzothiazolinone Hydrazine: A Preliminary Study

A Spectrophotometric Method for the Determination of Aldehyde Oxidase Activity Using 3-Methyl-2- Benzothiazolinone Hydrazine: A Preliminary Study

Maryam Siah,
Mohammad Hossein Farzaei,
Mohammad Reza Ashrafi-Kooshk,
Hadi Adibi,
Reza Khodarahmi

Siah M, Farzaei MH, Ashrafi-Kooshk MR, Adibi H, Khodarahmi R. A Spectrophotometric Method for the Determination of Aldehyde Oxidase Activity Using 3-Methyl-2- Benzothiazolinone Hydrazine: A Preliminary Study. J Rep Pharm Sci. 2017;6(1):e147619. doi:

31
Jan
2016
A Peroxidase-linked Spectrophotometric Assay for the Detection of Monoamine Oxidase Inhibitors

A Peroxidase-linked Spectrophotometric Assay for the Detection of Monoamine Oxidase Inhibitors

Kangkang Zhi,
Zhongduo Yang,
Jie Sheng,
Zongmei Shu,
Yin Shi

Zhi K, Yang Z, Sheng J, Shu Z, Shi Y. A Peroxidase-linked Spectrophotometric Assay for the Detection of Monoamine Oxidase Inhibitors. Iran J Pharm Res. 2016;15(1):e125084. doi: https://doi.org/10.22037/ijpr.2016.1782

30
Apr
2014
A Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples

A Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples

Masoud Reza Shishehbore,
Zahra Aghamiri

Shishehbore MR, Aghamiri Z. A Highly Sensitive Kinetic Spectrophotometric Method for the Determination of Ascorbic Acid in Pharmaceutical Samples. Iran J Pharm Res. 2014;13(2):e125552. doi: https://doi.org/10.22037/ijpr.2014.1499

29
Jun
2013
Fluorimetry as a Simple and Sensitive Method for Determination of Catalase Activity

Fluorimetry as a Simple and Sensitive Method for Determination of Catalase Activity

Saeed Naazeri,
Mosayeb Rostamian,
Bahram Yaghmaei,
Mehdi Hedayati

Naazeri S, Rostamian M, Yaghmaei B, Hedayati M. Fluorimetry as a Simple and Sensitive Method for Determination of Catalase Activity. Zahedan J Res Med Sci. 2014;16(2):. doi:

2
Mar
2015
Assay of Pyrantel Pamoate Using Iron (III) Chloride and Three Complexing Agents by Spectrophotometry

Assay of Pyrantel Pamoate Using Iron (III) Chloride and Three Complexing Agents by Spectrophotometry

Nagaraju Swamy,
Kanakapura Basavaiah

Swamy N, Basavaiah K. Assay of Pyrantel Pamoate Using Iron (III) Chloride and Three Complexing Agents by Spectrophotometry. J Rep Pharm Sci. 2015;4(2):e147675. doi:

More by these authors

Mohammad Hossein SorouraddinPubMedScholar
Ebrahim FooladiPubMedScholar
Abdolhossein NaseriPubMedScholar
Mohammad-Reza RashidiPubMedScholar
Share
Cited by
Metrics