International Cardiovascular Research Journal
An annual journal in scientific affiliation with the Cardiovascular Research Center, Shiraz University of Medical Sciences
Image Credit:Int Cardiovasc Res J
Outline
Difficult Coronary Sinus Cannulation during Cardiac Resynchronization Therapy due to its Diverticulum
Authors
Abstract
Coronary sinus (CS) diverticulum is one the different types of malformations of the right atrium and CS. It can be the primary focus of supraventricular arrhythmias and complicate CS lead implantation during cardiac resynchronization therapy (CRT) device implantation. Herein, we report on a case of CS diverticulum that caused difficulty in CS lead insertion during CRT implantation.
Highlights
References
- 1.The references are available in PDF.
Copyright
© 2017, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
Implanting CRT via Endo-Cardiac Route When Tricuspid Valve is Metallic
Jorat MV, Aslani A, Nikoo MH. Implanting CRT via Endo-Cardiac Route When Tricuspid Valve is Metallic. Int Cardiovasc Res J. 2017;8(1):e12059. doi:
A Case of Complete Unroofed Coronary Sinus Syndrome Combined With Coronary Sinus Stenosis Leading to Asymptomatic Presentation
Kim HR, Yoo SM, Lee HY, Rho JY, Yang WI, et al. A Case of Complete Unroofed Coronary Sinus Syndrome Combined With Coronary Sinus Stenosis Leading to Asymptomatic Presentation. I J Radiol. 2015;12(3):e16063. doi: https://doi.org/10.5812/iranjradiol.16063v2
Myocardial infarction caused by active-fixation atrial pacing lead screwed into the anterior descending coronary artery
Majauskienė E, Aucina G, Semeniene P, Jurkuvenas P, Serpytis P. Myocardial infarction caused by active-fixation atrial pacing lead screwed into the anterior descending coronary artery. Int Cardiovasc Res J. 2018;12(4):e68816. doi:
Single Chamber Pacemaker Implantation in a Patient with Persistent Left Superior Vena Cava and Right Superior Vena Cava Occlusion: A Technical Challenge Solved with a Particular Right Ventricular Lead
Mazzone P, Guarracini F, Radinovic A, Romano S, Migliore F, et al. Single Chamber Pacemaker Implantation in a Patient with Persistent Left Superior Vena Cava and Right Superior Vena Cava Occlusion: A Technical Challenge Solved with a Particular Right Ventricular Lead. Int Cardiovasc Res J. 2017;9(3):e11242. doi:
Successful Management of Right Ventricular Perforation Associated with a Pacemaker Lead During Off-Pump CABG Surgery: A Case Report
Tarbiat M, Bakhshaei MH, Moradi M. Successful Management of Right Ventricular Perforation Associated with a Pacemaker Lead During Off-Pump CABG Surgery: A Case Report. Anesth Pain Med. 2017;7(4):e57799. doi: https://doi.org/10.5812/aapm.57799
- Scopus by DOI: 0
Last Update: 3 weeks ago
- Scopus by Title: 0
Last Update: 3 weeks ago
- Scopus by Title (Ref): 0
Last Update: 3 weeks ago
- CrossRef: 0
Last Update: 6 hours ago
- OpenAlex: 0
Last Update: 1 day ago
- OpenCitations: 0
Last Update: 4 days ago