Comparison of maternal and umbilical cord blood selenium levels in preterm and term neonates

Authors

Ali Asghar Alipour1, Homa Babaei1, Mitra Hemmati1, Mansour Rezaei2, Zahra Hoseininezhad1,*
1Dept. of Pediatrics, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran
2Dept. of Biostatistics & Epidemiology, Social development and Health Promotion Research Center, Kermanshah University of Medical Sciences, Kermanshah, Iran
*Corresponding Author: Corresponding author: Zahra Hoseininezhad, Dept. of Pediatrics, School of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran, Tel: +989171122799 Email: [email protected]

Journal of Kermanshah University of Medical Sciences:Vol. 18, issue 9; e74018
Published online:Dec 29, 2014
Article type:Research Article
Received:Sep 29, 2014
Accepted:Dec 09, 2014
How to Cite:Alipour AA, Babaei H, Hemmati M, Rezaei M, Hoseininezhad Z. Comparison of maternal and umbilical cord blood selenium levels in preterm and term neonates. J Kermanshah Univ Med Sci. 2014;18(9):e74018. doi: https://doi.org/10.22110/jkums.v18i9.2069

Abstract

Background: Selenium is a micronutrient that plays an important role in immunological mechanisms and body's resistance to pathogens, and may drastically impact the outcome of pregnancy. The purpose of this study was to compare selenium level in maternal blood and neonatal umbilical cord between term and preterm neonates.

Methods: In this cross–sectional analytical study, the study population consisted of term and preterm neonates that were born at Imam Reza hospital, Kermanshah, and their mothers in 2013. 82 samples were selected, and selenium level in maternal blood and neonatal umbilical cord was measured by atomic absorption spectrophotometry. Data were analyzed by SPSS-21 software using independent t-test, U Mann-Whitney and Pearson correlation coefficient.

Results: Serum selenium levels in the umbilical cord blood of term and preterm neonates were 70.11±11.6 and 56.98±13.13 µg/L, respectively, that showed a statistically significant difference (P<0.001). Serum selenium levels in the maternal blood of term and preterm neonates were 92.77±12.87 and 81.29±15.89 µg/L, respectively, which indicated a significant difference (P<0.001). However, in both term and preterm infants, there was a significant correlation between serum selenium level of maternal blood and neonatal umbilical cord blood (P<0.001).

Conclusion: Serum selenium level in maternal blood and neonatal umbilical cord blood of preterm neonates was lower than that of term neonates. Moreover, there was a significantly direct correlation between serum selenium level of maternal blood and neonatal umbilical cord blood.

Highlights

Fulltext

References

  • 1.
    The references of this article is available on PDF.

Copyright

© 2014, Journal of Kermanshah University of Medical Sciences. This open-access article is available under the Creative Commons Attribution-NonCommercial 4.0 (CC BY-NC 4.0) International License (https://creativecommons.org/licenses/by-nc/4.0/), which allows for the copying and redistribution of the material only for noncommercial purposes, provided that the original work is properly cited.

Similar Articles

28
Feb
2018
The Relationship between Maternal and Neonatal Umbilical Cord Blood Lead Levels and their Correlation with Neonatal Anthropometric Indices

The Relationship between Maternal and Neonatal Umbilical Cord Blood Lead Levels and their Correlation with Neonatal Anthropometric Indices

Zohreh Torabi,
Mohammad Halvachi,
Mehran Mohseni,
Hamid Khederlou

Torabi Z, Halvachi M, Mohseni M, Khederlou H. The Relationship between Maternal and Neonatal Umbilical Cord Blood Lead Levels and their Correlation with Neonatal Anthropometric Indices. J Compr Ped. 2018;9(1):e55056. doi: https://doi.org/10.5812/compreped.55056

26
Dec
2024
Umbilical Cord Zinc Levels and Neonatal Anthropometric Measures: A Cross-Sectional Study in Iran

Umbilical Cord Zinc Levels and Neonatal Anthropometric Measures: A Cross-Sectional Study in Iran

Mahbod Kaveh,
Marzieh Darabi,
Razieh Sangsari,
Roksana Moeini,
Maryam Veysizadeh,
Mohammad Reza Zarkesh
,et al.

Kaveh M, Darabi M, Sangsari R, Moeini R, Veysizadeh M, et al. Umbilical Cord Zinc Levels and Neonatal Anthropometric Measures: A Cross-Sectional Study in Iran. Inn J Pediatr. 2025;35(2):e150308. doi: https://doi.org/10.5812/ijp-150308

26
Feb
2020
Comparison of Mercury Level of Cord Blood in Term and Preterm Neonates

Comparison of Mercury Level of Cord Blood in Term and Preterm Neonates

Nastaran Khosravi,
Abulhassan Divband,
Nasrin Fathabadi,
Nasrin Khalesi,
Manije Sahlani,
Monireh Monfaredi
,et al.

Khosravi N, Divband A, Fathabadi N, Khalesi N, Sahlani M, et al. Comparison of Mercury Level of Cord Blood in Term and Preterm Neonates. J Compr Ped. 2020;11(2):e13302. doi: https://doi.org/10.5812/compreped.13302

1
Dec
2014

Lipid Profile of Cord Blood in Term Newborns

Seyed Alinaghi Kazemi,
Mansour Sadeghzadeh

Kazemi SA, Sadeghzadeh M. Lipid Profile of Cord Blood in Term Newborns. J Compr Ped. 2014;5(4):e23759. doi: https://doi.org/10.17795/compreped-23759

25
Oct
2012

Determination of the Lipid Profile of Cord Blood in Neonates and its Correlation with Maternal Age in Iran

Shahla Vaziri Esfarjani,
Elham Iravani,
Maryam Razzaghi Azar

Vaziri Esfarjani S, Iravani E, Razzaghi Azar M. Determination of the Lipid Profile of Cord Blood in Neonates and its Correlation with Maternal Age in Iran. J Compr Ped. 2013;4(1):72-6. doi: https://doi.org/10.17795/compreped-6347

More by these authors

Ali Asghar AlipourPubMedScholar
Homa BabaeiPubMedScholar
Mitra HemmatiPubMedScholar
Mansour RezaeiPubMedScholar
Zahra HoseininezhadPubMedScholar
Share
Cited by
Metrics