Koomesh
Journal of Semnan University of Medical Sciences
Evaluation of 4D-NCAT Phantom to simulate Dynamic Behavior of Radiopharmaceutical in Myocardium
Abstract
Introduction: Studying the heart tissue kinetics can lead to expedient diagnostic technique to study the spatial and temporal cardiac activity simultaneously. Simulations of this process requires phantom, which applies dynamic activity changes gradually to the regions of interest. The objective of this study was to validate the efficiency of 4D-NCAT phantom data in the dynamic activity changes in course of the time. Materials and Methods: The accuracy of constant, ascending and descending steep Time activity Curves (TACs) in blood and myocardial tissue were measured after i99m-Tc teboroxime injection. Also, the accuracy of phantom output data was measured in different resolution. Results: Our study showed that the response of the dynamic 4D NCAT phantom for constant curves had just some slight errors. The average relative differences between input and output data for steeper TACs were noteworthy in both ascending and descending mode. The results showed that by increasing the temporal data sampling, the average difference between input and outputs were decreased. Overall, only 0.6% of the assessed samples depicted relative errors larger than 0.1%. Conclusion: The primary studies with available 4D NCAT software, version 2012, revealed some challenges in applying intended activity with TACs, which referred to and were subsequently resolved by Dr. Paul Segars revisions. Overall, the modified 4D NCAT phantom software is able to accurately simulate the organ dynamics.
Copyright
© 2015, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
Comparison of Reconstruction Methods in a Small Animal Cardiac Positron Emission Tomography Study Using a 18F-Labeled Myocardial Agent, [18F] FPTP
Kim H, Lee B, Han Kim J, Bom H, Kim D, et al. Comparison of Reconstruction Methods in a Small Animal Cardiac Positron Emission Tomography Study Using a 18F-Labeled Myocardial Agent, [18F] FPTP. I J Radiol. 2017;14(1):e13463. doi: https://doi.org/10.5812/iranjradiol.26806
Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen
Adibi A, Shahbazi A. Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen. I J Radiol. 2014;11(1):4617. doi: https://doi.org/10.5812/iranjradiol.4617
Radiation Dose and Image Quality Assessment of the Bolus Timing Method for CT Angiography
Seong Kim M, Lee J, Geun Kim S, Cheol Kweon D. Radiation Dose and Image Quality Assessment of the Bolus Timing Method for CT Angiography. I J Radiol. 2017;14(2):e31918. doi: https://doi.org/10.5812/iranjradiol.31918
Role of Lesion-to-Background Activity Ratio and Background Activity in Optimization of Reconstruction Protocols for FDG PET/CT Images of Overweight Patients: A Phantom Study
Rezvani S, Ghafarian P, Bakhshayesh Karam M, Ay M. Role of Lesion-to-Background Activity Ratio and Background Activity in Optimization of Reconstruction Protocols for FDG PET/CT Images of Overweight Patients: A Phantom Study. I J Radiol. 2023;20(1):e129306. doi: https://doi.org/10.5812/iranjradiol-129306
Investigation of the Clinical Efficacy of 99mTc-Sestamibi Washout in Patients with Acute Myocardial Infarction and Comparison with Stress Myocardial Imaging with 99mTc-Sestamibi Using a Two-Day Protocol
Ota M, Hyodo F, Matsuo S, Kato T, Kawai N, et al. Investigation of the Clinical Efficacy of 99mTc-Sestamibi Washout in Patients with Acute Myocardial Infarction and Comparison with Stress Myocardial Imaging with 99mTc-Sestamibi Using a Two-Day Protocol. I J Radiol. 2022;19(2):e122423. doi: https://doi.org/10.5812/iranjradiol-122423
- Scopus by DOI: 0
Last Update: 1 week ago
- Scopus by Title: 0
Last Update: 1 week ago
- Scopus by Title (Ref): 0
Last Update: 1 week ago
- CrossRef: 0
Last Update: 5 days ago
Ordering Reprints
Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC
Author(s):