Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen

Author(s):
Atoosa AdibiAtoosa Adibi1,*, Ali ShahbaziAli Shahbazi1
1Department of Radiology, Isfahan University of Medical Sciences, Isfahan, Iran
*Corresponding Author: Department of Radiology, Alzahra Hospital, Soffeh Ave., Isfahan, Iran. Tel: +983116255555, Fax: +98-3116687898, [email protected]. Email: [email protected]

IJ Radiology:Vol. 11, issue 1; 4617
Published online:Jan 29, 2014
Article type:Research Article
Received:Apr 02, 2012
Accepted:Oct 12, 2012
How to Cite:Adibi A, Shahbazi A. Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen. I J Radiol. 2014;11(1):4617. doi: https://doi.org/10.5812/iranjradiol.4617

Abstract

Background:

Bolus tracking can individualize time delay for the start of scans in spiral computed tomography (CT).

Objectives:

We compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector CT of abdomen.

Patients and Methods:

Adult patients referred for spiral CT of the abdomen were randomized into two groups; in group 1, the arterial and portal phases of spiral scans were started 25 s and 55 s after the start of contrast material administration; in group 2, using the automatic bolus tracking software, repetitive monitoring scans were performed within the lumen of the descending aorta as the region of interest with the threshold of starting the diagnostic scans as 60 HU. The contrast enhancement of the aorta, liver, and spleen were compared between the groups.

Results:

Forty-eight patients (23 male, 25 female, mean age=56.413.5 years) were included. The contrast enhancement of the aorta, liver, and spleen at the arterial phase was similar between the two groups (P > 0.05). Regarding the portal phase, the aorta and spleen were more enhanced in the bolus-tracking group (P<0.001). The bolus tracking provided more homogeneous contrast enhancement among different patients than the fixed time-delay technique in the liver at portal phase, but not at the arterial phase.

Conclusions:

The automatic bolus-tracking method, results in higher contrast enhancement of the aorta and spleen at the portal phase, but has no effect on liver enhancement. However, bolus tracking is associated with reduced variability for liver enhancement among different patients.

Full Text

Full text is available in PDF

Copyright

© 2014, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

20
Aug
2016

Radiation Dose and Image Quality Assessment of the Bolus Timing Method for CT Angiography

Myeong Seong Kim,
Jong-Woong Lee,
Sun Geun Kim,
Dae Cheol Kweon

Seong Kim M, Lee J, Geun Kim S, Cheol Kweon D. Radiation Dose and Image Quality Assessment of the Bolus Timing Method for CT Angiography. I J Radiol. 2017;14(2):e31918. doi: https://doi.org/10.5812/iranjradiol.31918

28
Nov
2022
Iran J Radiol

Contrast-Enhanced Chest Computed Tomography (CT) Scan with Low Radiation and Total Iodine Dose for Lung Cancer Detection Using Adaptive Statistical Iterative Reconstruction

Xili Li,
Shiyong Luo,
Suping Chen,
Du Wang,
Yiqing Tan

Li X, Luo S, Chen S, Wang D, Tan Y. Contrast-Enhanced Chest Computed Tomography (CT) Scan with Low Radiation and Total Iodine Dose for Lung Cancer Detection Using Adaptive Statistical Iterative Reconstruction. I J Radiol. 2022;19(4):e126572. doi: https://doi.org/10.5812/iranjradiol-126572

11
Apr
2016

Split-Bolus Multidetector-Row Computed Tomography Technique for Characterization of Focal Liver Lesions in Oncologic Patients

Michele Scialpi,
Luisa Pierotti,
Sabrina Gravante,
Alberto Rebonato,
Irene Piscioli,
Alfredo D’Andrea
,et al.

Scialpi M, Pierotti L, Gravante S, Rebonato A, Piscioli I, et al. Split-Bolus Multidetector-Row Computed Tomography Technique for Characterization of Focal Liver Lesions in Oncologic Patients. I J Radiol. 2016;13(2):e20143. doi: https://doi.org/10.5812/iranjradiol.20143

14
Jan
2016

Split-Bolus Single-Pass Multidetector-Row CT Protocol for Diagnosis of Acute Pulmonary Embolism

Michele Scialpi,
Alberto Rebonato,
Lucio Cagini,
Luca Brunese,
Irene Piscioli,
Luisa Pierotti
,et al.

Scialpi M, Rebonato A, Cagini L, Brunese L, Piscioli I, et al. Split-Bolus Single-Pass Multidetector-Row CT Protocol for Diagnosis of Acute Pulmonary Embolism. I J Radiol. 2016;13(1):e19844. doi: https://doi.org/10.5812/iranjradiol.19844

24
Mar
2024
I J Radiol

Study of Low kV, Low Contrast Agent Dosage, and Low Contrast Agent Flow Rate Scan in Computed Tomography Angiography of Children's Liver

Lan Wu,
Shilong Tang,
Wushuang Chen,
Xin Chen,
Li Zhang,
Ling He

Wu L, Tang S, Chen W, Chen X, Zhang L, et al. Study of Low kV, Low Contrast Agent Dosage, and Low Contrast Agent Flow Rate Scan in Computed Tomography Angiography of Children's Liver. I J Radiol. 2023;20(4):e138586. doi: https://doi.org/10.5812/iranjradiol-138586

Download PDF554.78 KB

Crossmark

Crossmark

Checking

Share on
Cited by
Metrics

Ordering Reprints

Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC