Dosimetry of organ at risks in Orthopantomography
Abstract
Introduction: Orthopantomography is a common imaging technique of the jaw. Although in compare to other diagnostic radiology methods, the dose of radiation received by the patient is relatively low in orthopantomography, still is remained as the most common method in diagnostic radiology. Therefore, because of the commonalty of this method, it seemed rational to estimate the dose received by the Organ At Risks (OARs) . Materials and Methods: This study has been designed to determine the surface dose received by the eyes, parotids, thyroid and submandibular salivary glands using Gafchromic films in 20 patients referred to imaging centers (digital and analog). To increase the repeatability of the technique, each measurement was triplicated and the results were presented as mean (SD) . Results : The mean measured surface dose received by the submandibular glands (left, right and center), thyroid (left and right), parotid (left and right) and eye (left and right) for the digital system were 4.17, 4.65, 5.08 and 4.74 and for the analog system were 10.33, 10.12, 10.28 and 10.73, respectively . Conclusion: This study showed no difference in surface dose received by the left and right eyes, left and right thyroid, left and right parotid, left, right and center submandibular glands in any of the digital or analog systems studied (P ≤0.05). In addition, the surface dose received by the selected organs in digital system was significantly lower than that by the analog system (P ≤0.05) .
Copyright
© 2015, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
Using Optimal Projections for Reduction of Radiation Risks in Some Radiographies
Chaparian A, Kanani A. Using Optimal Projections for Reduction of Radiation Risks in Some Radiographies. I J Radiol. 2014;11(30th Iranian Congress of Radiology):e21288. doi: https://doi.org/10.5812/iranjradiol.21288
Depth dose of critical organs of phantom based on surface dose exposed with Dual X-ray absorptiometry: pencil beam using TLD dosimetry
Sharafi A, Mokhtari M, Mokhlesian N, Larijani B, KazemNezhad A. Depth dose of critical organs of phantom based on surface dose exposed with Dual X-ray absorptiometry: pencil beam using TLD dosimetry. koomesh. 2009;10(2):e152226. doi:
Investigating the Effect of mA Variation on Absorbed Dose to Salivary Glands and Mandible Body in CBCT
Alirezaei Z, Jabbari K, Dehghani T, Tavakoli M, Mehdizadeh M, et al. Investigating the Effect of mA Variation on Absorbed Dose to Salivary Glands and Mandible Body in CBCT. I J Radiol. 2019;16(1):e13383. doi: https://doi.org/10.5812/iranjradiol.13383
Cumulative Radiation Dose and Cancer Risk Estimation in Common Diagnostic Radiology Procedures
Nikzad S, Pourkaveh M, Jabbari Vesal N, Gharekhanloo F. Cumulative Radiation Dose and Cancer Risk Estimation in Common Diagnostic Radiology Procedures. I J Radiol. 2018;15(3):e60955. doi: https://doi.org/10.5812/iranjradiol.60955
Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography
Kim J, Yoon S, Seo D, Nam S, Kim J. Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography. I J Radiol. 2016;13(1):e22514. doi: https://doi.org/10.5812/iranjradiol.22514
- Scopus by DOI: 0
Last Update: 1 week ago
- Scopus by Title: 4
Last Update: 1 week ago
- Scopus by Title (Ref): 4
Last Update: 1 week ago
- CrossRef: 0
Last Update: 5 days ago
Ordering Reprints
Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC
Author(s):