Koomesh
Journal of Semnan University of Medical Sciences
Assessment the effects of scanning and technical parameters on the detection of pulmonary nodules at different computed tomography systems
Abstract
Introduction: Computed tomography (CT) is the most sensitive imaging technique for the detection of pulmonary nodules and metastases, and may reveal peripheral nodules as small as 2 mm in diameter. Detection of metastases would influence treatment. CT is also useful for planning biopsy or surgical resection of putative metastases. It is therefore important to optimize the CT scanning protocol, with the goal of maximizing the sensitivity and specificity of detecting pulmonary nodules while minimizing patient dose to ionizing radiation. Materials and Methods: The chest phantom that we used made of clear transparent plastic that has inside shape and dimensions of a sheep thorax to hold simulated nodules-lung preparation of a sheep. The number of lesions per lung ranged from 40 to 50 that sized 1mm to 5 mm at two categories calcified and soft tissue (myocardium tissue).the approximate sites of implantation and the sizes of the lesions were documented. These maps later served as references for nodule detection. To simulate the radiation-absorbing qualities, Urine bags are filled with solution 15grm iodine/lit water (20mlit urografin %76 per one liter water). The phantoms are inflated through tracheal tubes during the experiment. The CT scans are obtained by using three systems at same technical and exposure parameters. Radiologist reported the images. Results: Probability of nodules detection at three CT scan systems for slice thickness, 2 mm in comparing with slice thicknss,10mm and also 5mm differed significantly (p
Copyright
© 2005, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
Pulmonary Nodules CT Scan
seilanian toosi F. Pulmonary Nodules CT Scan. I J Radiol. 2014;11(30th Iranian Congress of Radiology):e21245. doi:
Value of Radiodensity Determined by Enhanced Computed Tomography for the Differential Diagnosis of Lung Masses
Xie M. Value of Radiodensity Determined by Enhanced Computed Tomography for the Differential Diagnosis of Lung Masses. I J Radiol. 2011;8(3):. doi: https://doi.org/10.5812/kmp.iranjradiol.17351065.3128
Effectiveness of Twin-Beam Dual-Energy Computed Tomography in Characterization of Solitary Pulmonary Nodules Larger Than 5 mm
Turkoglu S, Özgökçe M. Effectiveness of Twin-Beam Dual-Energy Computed Tomography in Characterization of Solitary Pulmonary Nodules Larger Than 5 mm. I J Radiol. 2024;21(3):e149360. doi: https://doi.org/10.5812/iranjradiol-149360
Contrast-Enhanced Chest Computed Tomography (CT) Scan with Low Radiation and Total Iodine Dose for Lung Cancer Detection Using Adaptive Statistical Iterative Reconstruction
Li X, Luo S, Chen S, Wang D, Tan Y. Contrast-Enhanced Chest Computed Tomography (CT) Scan with Low Radiation and Total Iodine Dose for Lung Cancer Detection Using Adaptive Statistical Iterative Reconstruction. I J Radiol. 2022;19(4):e126572. doi: https://doi.org/10.5812/iranjradiol-126572
Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography
Al Ewaidat H, Zheng X, Khader Y, Abdelrahman M, Mustafa Alhasan MK, et al. Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography. I J Radiol. 2018;15(3):e59554. doi: https://doi.org/10.5812/iranjradiol.59554
- Scopus by DOI: 0
Last Update: 3 weeks ago
- Scopus by Title: 0
Last Update: 3 weeks ago
- Scopus by Title (Ref): 0
Last Update: 3 weeks ago
- CrossRef: 0
Last Update: 20 hours ago
Ordering Reprints
Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC