An assay on the quality of thallous chloride radiopharmaceutical produced in atomic energy organization of Iran

Authors

Esmaeil MehrAra,*, Hossein Afarideh
*Corresponding Author: Email: [email protected]

Koomesh:Vol. 1, issue 3; 41-47
Published online:Apr 15, 2000
Article type:Research Article
How to Cite:MehrAra E, Afarideh H. An assay on the quality of thallous chloride radiopharmaceutical produced in atomic energy organization of Iran. koomesh. 2000;1(3):e153104. doi:

Abstract

Introdution . Thall ous chloride (TI-201) radiopharmaceutical is routinly used for heart imaging in nuclear medicine departments. The goal of this project was to study the quality of TI-201 radioph armaceuticals produced in cyclotron department of atomic energy organization of Iran according to European and United States standards. Materials and Methods. This radiopharmaceuti cal was produc ed in 15 stages thro ugh 2°'TI (p,3n) 201 Pb ~ZOl TI nuclear reaction in which the inciden t pro ton energy is 28 Mev. Radionuclidic impurities (ZO'Ph, zo"TI, 2O'TI) were det ermin ed by gamma-spectrometer with high pure Ge (HPGe) detector for production and pre -calibration dates and for one 20lTI half life (73.5 hr) later. The radiochemical impurity (TP+ in comparison to TI+), specific activity and activity distr ibution in vials were determined by electrophoresis, polarography and gamma spectrometry, and dose calibra tor , respectively. Results. In fifthteen production stages radionuclidic and radiochemical purity of product and it's specific activity have been higher than 97%, 95%, and 3.7 GBq/mg-TI resp ectively But in three stages zo'Pb impurity has been higher than 0.3% determined in USP. Accuracy of activity distribution in vials was higher than 10% in all stages. Conclusion. The results show that the product quality is in accordance to the British and Euro pean standards (BP and EP). In accordance to the United States Pharmacopoeia (USP), although in three stages of fifthteen production stages 2°'Pb impurity has been higher than 0.3% determined in USP, radio nuclidic purity has bee n acceptable (>99%).

Copyright

© 2000, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

15
Feb
2001

Staff radiation doses associated with nuclear procedures and efficacy of syringe shield for reduction dose

Peyman Hejazi,
Mehdi Sohrabi

Hejazi P, Sohrabi M. Staff radiation doses associated with nuclear procedures and efficacy of syringe shield for reduction dose. koomesh. 2001;2(2):e151927. doi:

31
Jan
2012

Production, Quality Control and Pharmacokinetic Studies of 177Lu-EDTMP for Human Bone Pain Palliation Therapy Trials

Ali Bahrami-Samani,
Akbar Anvari,
Amir Reza Jalilian,
Simindokht Shirvani-Arani,
Hassan Yousefnia,
Mahmoud Reza Aghamiri
,et al.

Bahrami-Samani A, Anvari A, Jalilian AR, Shirvani-Arani S, Yousefnia H, et al. Production, Quality Control and Pharmacokinetic Studies of 177Lu-EDTMP for Human Bone Pain Palliation Therapy Trials. Iran J Pharm Res. 2012;11(1):e125787. doi: https://doi.org/10.22037/ijpr.2012.1081

17
May
2007

The radio nuclides in piping drinking water, cultivated soil and consumed food material from Zahedan city

Abbas Hosseini

Hosseini A. The radio nuclides in piping drinking water, cultivated soil and consumed food material from Zahedan city. Zahedan J Res Med Sci. 2007;9(2):e94806. doi:

31
Dec
2018
Preparation of 177Lu-Rituximab and Comparison with 131I-Rituximab Radiolabeled with Chloramine-T Method

Preparation of 177Lu-Rituximab and Comparison with 131I-Rituximab Radiolabeled with Chloramine-T Method

Fariba Johari Daha,
Samira Rasaneh,
Saleh Salehi Zahabi

Johari Daha F, Rasaneh S, Salehi Zahabi S. Preparation of 177Lu-Rituximab and Comparison with 131I-Rituximab Radiolabeled with Chloramine-T Method. J Clin Res Paramed Sci. 2018;7(2):e87181. doi: https://doi.org/10.5812/jcrps.87181

1
Sep
2019

Evaluation of cellular S-value of auger electrons emitting 111In radionuclide by Geant4 and its comparison with MCNP5 Monte Carlo codes and MIRD published data

Mohammad Ali Tajikmansoury,
Hadi Taleshi Ahangari,
Hossein Rajabi,
Majid Jadidi

Tajikmansoury MA, Taleshi Ahangari H, Rajabi H, Jadidi M. Evaluation of cellular S-value of auger electrons emitting 111In radionuclide by Geant4 and its comparison with MCNP5 Monte Carlo codes and MIRD published data. koomesh. 2019;21(3):e153117. doi:

More by these authors

Esmaeil MehrAraPubMedScholar
Hossein AfaridehPubMedScholar
Share
Cited by
Metrics