Dear Editor,
Recently, with great interest we read the review article by Zeraati et al. entitled “A review article: access recirculation among end stage renal disease patients undergoing maintenance hemodialysis” in your most valuable journal (1). The author summarized some of observations about causes and clinical significance of arteriovenous (AV) fistula recirculation, techniques for accurate assessment and main source of pitfall in calculation of access recirculation (AR) (1). Hemodialysis AR occurs when the blood urea concentration in arterial line is lower than that of systemic circulation, indicating that dialyzed blood returning through the venous needle reenters the HD machine through the arterial needle (2).
It is well established that periodic assessment of AR and early detection and treatment of this problem has an important effect in better management of hemodialysis (HD) patients (3-5).
High degrees of AR reduce solute concentration gradients across the dialysis membrane during HD by mixing dialyzed blood with undialyzed blood and reduce the effective clearance of urea and adequacy of HD. Therefore, presence of AR among HD patients leads to significant inadequate dialysis in long-term, which is an important contributor to morbidity and mortality among these patients (6-11). It is also suggested that high degree of AR is one of the surrogate markers of AV fistula inflow problems and periodic assessment of AR can be used as a screening tool for early detection of this problem, which improves long-term AV fistula patency rates (12).
However, it seems that periodic assessment of AR is a neglected issue and most HD centers do not measure AR in HD patients (4).
The most common cause of AR is the presence of stenosis in venous side of the AV fistula, which restricts dialyzed blood venous outflow and the other common cause of AR is inadequate arterial blood flow rate because of AV fistula problems (3, 12).
Improper needle placement by HD staff which is due to lack of familiarity with the access anatomy is another cause of backflow or AV fistula recirculation and therefore HD staff have to be educated about the role of close proximity and improper arterial and venous needles placement (13).
An access diagram should be obtained from the surgeon who constructed the AV fistula for appropriate placement of arterial and venous needles by HD staff. The access anatomy can be determined by temporarily occluding the mid portion of AV fistula. After occluding the mid portion of AV fistula, the portion retaining a pulse is the arterial side and the other portion is the venous side of access (3, 12).

Acknowledgments

References

  • 1.
    Zeraati A, Beladi Mousavi SS, Beladi Mousavi M. A review article: access recirculation among end stage renal disease patients undergoing maintenance hemodialysis. Nephrourol Mon. 2013;5(2):728-32. [PubMed ID: 23841034]. https://doi.org/10.5812/numonthly.6689.
  • 2.
    Tonelli M, Jindal K, Hirsch D, Taylor S, Kane C, Henbrey S. Screening for subclinical stenosis in native vessel arteriovenous fistulae. J Am Soc Nephrol. 2001;12(8):1729-33. [PubMed ID: 11461946].
  • 3.
    Mousavi SB, Tavazoe M, Hayati F, Sametzadeh M. Arterio-Venous fistula recirculation in hemodialysis: causes and prevalences. Shiraz E Med J. 2010;11(4):219-24.
  • 4.
    May RE, Himmelfarb J, Yenicesu M, Knights S, Ikizler TA, Schulman G, et al. Predictive measures of vascular access thrombosis: a prospective study. Kidney Int. 1997;52(6):1656-62. [PubMed ID: 9407514].
  • 5.
    Tessitore N, Bedogna V, Poli A, Impedovo A, Antonucci F, Teodori T, et al. Practice patterns in the management of arteriovenous fistula stenosis: a northern Italian survey. J Nephrol. 2006;19(2):200-4. [PubMed ID: 16736421].
  • 6.
    Beladi-Mousavi SS, Alemzadeh-Ansari MJ, Alemzadeh-Ansari MH, Beladi-Mousavi M. Long-term survival of patients with end-stage renal disease on maintenance hemodialysis: a multicenter study in Iran. Iran J Kidney Dis. 2012;6(6):452-6. [PubMed ID: 23146984].
  • 7.
    Feily A, Dormanesh B, Ghorbani AR, Moosavi Z, Kouchak M, Cheraghian B, et al. Efficacy of topical cromolyn sodium 4% on pruritus in uremic nephrogenic patients: a randomized double-blind study in 60 patients. Int J Clin Pharmacol Ther. 2012;50(7):510-3. [PubMed ID: 22732382].
  • 8.
    Beladi-Mousavi SS, Beladi-Mousavi M, Hayati F, Talebzadeh M. Effect of intranasal DDAVP in prevention of hypotension during hemodialysis. Nefrologia. 2012;32(1):89-93. [PubMed ID: 22294007].
  • 9.
    Beladi Mousavi SS, Alemzadeh Ansari MJ, Cheraghian B. Outcome of patients on haemodialysis in Khuzestan, Iran. NDT Plus. 2011;4(2):143-4. [PubMed ID: 25984142]. https://doi.org/10.1093/ndtplus/sfq207.
  • 10.
    Tamadon MR, Beladi-Mousavi SS. Erythropoietin; a review on current knowledge and new concepts. J Renal Inj Prev. 2013;2(4):119-21. [PubMed ID: 25340147]. https://doi.org/10.12861/jrip.2013.38.
  • 11.
    Beladi Mousavi SS, Sametzadeh M, Hayati F, Fatemi SM. Evaluation of acquired cystic kidney disease in patients on hemodialysis with ultrasonography. Iran J Kidney Dis. 2010;4(3):223-6. [PubMed ID: 20622311].
  • 12.
    Tentori F, Hunt WC, Rohrscheib M, Zhu M, Stidley CA, Servilla K, et al. Which targets in clinical practice guidelines are associated with improved survival in a large dialysis organization? J Am Soc Nephrol. 2007;18(8):2377-84. [PubMed ID: 17634440]. https://doi.org/10.1681/ASN.2006111250.
  • 13.
    Schneditz D. Recirculation, a seemingly simple concept. Nephrol Dial Transpl. 1998;13(9):2191-3. https://doi.org/10.1093/ndt/13.9.2191.

Similar Articles

31
Mar
2015

Access Recirculation in Hemodialysis

Fatemeh Hayati,
Shokouh Shayanpour,
Mohammad Faramarzi

Hayati F, Shayanpour S, Faramarzi M. Access Recirculation in Hemodialysis. Shiraz E-Med J. 2015;16(3):e59875. doi: https://doi.org/10.17795/semj27548

30
Mar
2013

A Review Article: Access Recirculation Among End Stage Renal Disease Patients Undergoing Maintenance Hemodialysis

Abbasali Zeraati,
Seyed Seifollah Beladi Mousavi,
Marzieh Beladi Mousavi

Zeraati A, Beladi Mousavi SS, Beladi Mousavi M. A Review Article: Access Recirculation Among End Stage Renal Disease Patients Undergoing Maintenance Hemodialysis. Nephro-Urol Mon. 2013;5(2):728-32. doi: https://doi.org/10.5812/numonthly.6689

4
Oct
2010

Arterio-Venous Fistula Recirculation in Hemodialysis: Causes and Prevalences

SS Beladi Mousavi

Beladi Mousavi S. Arterio-Venous Fistula Recirculation in Hemodialysis: Causes and Prevalences. Shiraz E-Med J. 2010;11(4):20447. doi:

30
Jun
2008

Doppler Ultrasound Assessment of Well-Functioning Native Hemodialysis Access: Comparison with Sufficient Dialysis  

A. Alamdaran,
F. Nazemian,
H. Taheri

Alamdaran A, Nazemian F, Taheri H. Doppler Ultrasound Assessment of Well-Functioning Native Hemodialysis Access: Comparison with Sufficient Dialysis  . I J Radiol. 2008;5(2):e78992. doi:

30
Jun
2013

Native Arterio-Venous Fistula Is the Vascular Access of Choice for Hemodialysis in End Stage Renal Disease

Farooq Ahmad Ganie,
Hafeezulla Lone,
Abdul Majeed Dar,
Ghulam Nabi Lone,
Mohd Lateef Wani

Ahmad Ganie F, Lone H, Majeed Dar A, Nabi Lone G, Wani ML. Native Arterio-Venous Fistula Is the Vascular Access of Choice for Hemodialysis in End Stage Renal Disease. Int Cardiovasc Res J. 2013;7(2):e12706. doi:


Crossmark
Crossmark
Checking
Share on
Cited by
Metrics

Ordering Reprints

Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC 

Search Relations

Author(s):

Related Articles