Cover image of the article: The Effect of Various Contact Lenses on Intraocular Pressure Measurement by Goldman Tonometer

Image Credit:Zahedan J Res Med Sci

The Effect of Various Contact Lenses on Intraocular Pressure Measurement by Goldman Tonometer

Authors

Reza Yousofi1, Mohammad Mohamadian1, Abbas Azimi2, Monireh Mahjoob3,*
1MSPH Student of Rehabilitation Management, Tehran University of Medical Sciences, Tehran, Iran
2Department of O ptometry , Mashhad University of Medical Sciences, Mashhad, Iran
3Department of Optometry , Zahedan University of Medical Sciences, Health Promotion Center, Zahedan, Iran
*Corresponding Author: Department of Optometry , Zahedan University of Medical Sciences, Health Promotion Center, Zahedan, Iran Email: mahjoob_opt@yahoo.com

Zahedan Journal of Research in Medical Sciences:Vol. 16, issue 6
Published online:May 11, 2013
Article type:Research Article
Received:Oct 31, 2011
Accepted:Jan 12, 2012
How to Cite:Yousofi R, Mohamadian M, Azimi A, Mahjoob M. The Effect of Various Contact Lenses on Intraocular Pressure Measurement by Goldman Tonometer. Zahedan J Res Med Sci. 2014;16(6):. doi:

Abstract

Background: Today, contact lenses have extensive usages. Contact lens places on cornea, so it may induce variation on cornea and these variations can influence the measurement of intraocular pressure (IOP) by Goldman tonometer. The aim of this research was to study the effect of various contact lenses on measurement of intraocular pressure by Goldman tonometer.

Materials and Methods: In this study, 80 subjects aged 18-25 were selected randomly among patients of Al-Zahra ophthalmology center. None of them has any eye pathological problems. Before wearing the lens, intraocular pressure was measured, and then patients were divided into two groups of soft and hard contact lenses. Soft and hard contact lenses were placed on the eye for two hours, and the intraocular pressure was measured again.

Results: The mean of IOP before wearing contact lenses and two hours later was 15.96 mmHg and 13.93, s respectively. Paired test showed a significant difference between IOP before and after wearing contact lenses (p=0.001).There was no significant differences in mean of intraocular pressure decline before and after placing the contact lens in both soft and hard lenses.

Conclusion: According to this study, the intraocular pressure decreases after wearing contact lenses (CL). This decline may be due to variation in properties of cornea after wearing CL that can also affect IOP measurement.

Highlights

Fulltext

Fulltext is availale in the PDF.

References

  • 1.
    Refrences are available in PDf.

Copyright

© 2014, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

19
Mar
2007
Secondary Intraocular Lens Implantation in Yazd - Iran

Secondary Intraocular Lens Implantation in Yazd - Iran

A Rastegar,
MR Besharati,
MR Shoja

Rastegar A, Besharati M, Shoja M. Secondary Intraocular Lens Implantation in Yazd - Iran. J Kermanshah Univ Med Sci. 2007;10(4):e81829. doi:

31
Jul
2013
Opposite Clear Corneal Incisions versus Steep Meridian Incision Phacoemulsification for Correction of Pre-existing Astigmatism

Opposite Clear Corneal Incisions versus Steep Meridian Incision Phacoemulsification for Correction of Pre-existing Astigmatism

Mohammad Naim Aminifard,
Hamidreza Barkhordari-Yazdi,
Sadegh Eskandari

Aminifard MN, Barkhordari-Yazdi H, Eskandari S. Opposite Clear Corneal Incisions versus Steep Meridian Incision Phacoemulsification for Correction of Pre-existing Astigmatism. Zahedan J Res Med Sci. 2015;17(1):e1925. doi:

1
May
2014
Biofilm Formation by Staphylococcus epidermidis on Foldable and Rigid Intraocular Lenses

Biofilm Formation by Staphylococcus epidermidis on Foldable and Rigid Intraocular Lenses

Bibi Sedigheh Fazly Bazzaz,
Monireh Jalalzadeh,
Maryam Sanati,
Syamak Zarei-Ghanavati,
Bahman Khameneh

Fazly Bazzaz BS, Jalalzadeh M, Sanati M, Zarei-Ghanavati S, Khameneh B. Biofilm Formation by Staphylococcus epidermidis on Foldable and Rigid Intraocular Lenses. Jundishapur J Microbiol. 2014;7(5):e10020. doi: https://doi.org/10.5812/jjm.10020

26
Jun
2006
The blood pressure of upper and lower limbs in elderly patients under general anesthesia for cataract surgery

The blood pressure of upper and lower limbs in elderly patients under general anesthesia for cataract surgery

Mitra Jabalameli,
J Hashemi,
A Shaebanniya Mansour

Jabalameli M, Hashemi J, Shaebanniya Mansour A. The blood pressure of upper and lower limbs in elderly patients under general anesthesia for cataract surgery. Zahedan J Res Med Sci. 2006;8(2):e94903. doi:

15
Aug
2001
Intraocular pressure changes due to Succinyl-Choline and Atracuriom usage before and after operation with general anesthesia

Intraocular pressure changes due to Succinyl-Choline and Atracuriom usage before and after operation with general anesthesia

Gholamreza Daraei

Daraei G. Intraocular pressure changes due to Succinyl-Choline and Atracuriom usage before and after operation with general anesthesia. koomesh. 2001;2(3):e151930. doi:

More by these authors

Reza YousofiPubMedScholar
Mohammad MohamadianPubMedScholar
Abbas AzimiPubMedScholar
Monireh MahjoobPubMedScholar
Share
Cited by
Metrics