academic journalism

Evaluation of Mitral Annulus Diameter by Three-Dimensional Transesophageal Echocardiography and Its Correlation with Surgical Techniques

AUTHORS

avatar Nehzat Akiash ORCID 1 , avatar hoda mombeini ORCID 2 , * , avatar S.Zohreh Keshavarz ORCID 3 , avatar Mohammad Ali Sheikhi ORCID 4 , avatar Shirin Azizidoost ORCID 1 , avatar Behnam Gholizadeh ORCID 4 , avatar Ramtin Rezaee Kalantari ORCID 5

1 Atherosclerosis Research Center, Ahvaz Jundishapur University of Medical Sciences, Imam Khomeini Hospital, Ahvaz, IR Iran

2 Atherosclerosis Research Center, Tehran University of Medical Sciences, Sina Hospital, Tehran, IR Iran

3 General Cardiology, Ahvaz Jundishapur University of Medical Sciences, Imam Khomeini Hospital, Ahvaz, IR Iran

4 Department of Cardiac Surgery, Atherosclerosis Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, IR Iran

5 MD, Associate professor of cardiovascular surgery, Department of Cardiac Surgery, Atherosclerosis Research Center, Ahvaz Jundishapur University of Medical Science, Ahvaz, Iran

How to Cite: Akiash N, mombeini H, Keshavarz S, Sheikhi M A, Azizidoost S, et al. Evaluation of Mitral Annulus Diameter by Three-Dimensional Transesophageal Echocardiography and Its Correlation with Surgical Techniques. Int Cardio Res J. 2022;In Press(In Press):e126432.

ARTICLE INFORMATION

International Cardiovascular Research Journal: In Press (In Press); e126432
Published Online: November 06, 2022
Article Type: Research Article
Received: April 17, 2022
Revised: July 02, 2022
Accepted: July 12, 2022
READ FULL TEXT

Abstract

Background: Mitral Valve (MV) disease is responsible for a considerable number of
open cardiac surgeries. Selecting a befitting prosthetic valve is a matter of consideration.
Thus, accurate definition of mitral apparatus characteristics, particularly mitral annulus
dimensions, preoperatively can shed some light on the situation. The less invasive nature
of three-dimensional Transesophageal Echocardiography (3D-TEE) can turn it into a
practical modality for preoperative investigation of mitral anatomy.
Objectives: The present study aimed to investigate the correlation between the size of
mitral annulus attained through 3D-TEE and intraoperative size as well as the valve or
ring size finally placed in mitral position.
Methods: The study was conducted on 28 patients suffering from MV disease who
were candidates for MV surgery. All the patients underwent 3D-TEE. Mitral annulus
diameters including anteroposterior and intercommissural diameters were measured
delicately by using the Mitral Valve Navigation (MVN) tool. In the midst of surgery, a
mitral ring sizer was utilized in order to suggest the proper prosthesis size.
Results: The study results demonstrated that the sizer instrument was strongly
associated with the inserted prosthesis size and moderately with echocardiographic
annulus diameters. The correlation between the deployed prosthesis size and annulus
size obtained by intraoperative sizer and 3D echocardiography was assessed, as well.
The results indicated that ring sizer showed a strong positive relationship with the
intercommissural echocardiography diameter and a moderate positive relationship with
the anteroposterior echocardiography diameter.
Conclusion: The results revealed a good correlation between the echocardiography
measurements and intraoperative examination along with the deployed prosthesis size.
Thus, 3D-TEE could be considered a practical modality for the preoperative investigation
of mitral anatomy.

Fulltext

The full-text is available in pdf.

References

  • 1.

    The references are available in pdf.

© 2022, Shiraz University of Medical Sciences.
COMMENTS