International Journal of Cardiovascular Practice
Advanced Technologies in the Quantification of Mitral Valve
Abstract
The current study aimed at conducting an educational survey on the mitral valve using advanced technologies eSie Valve® and Q-Lab in echocardiography machines and also those mitral valve geometrical parameter measurements that can be easily calculated with MATLAB software offline in a personal computer as an echocardiographic desk for further information and recommendation before mitral valve repairs or other treatments.
Copyright
© 2018, International Journal of Cardiovascular Practice. This open-access article is available under the Creative Commons Attribution-NonCommercial 4.0 (CC BY-NC 4.0) International License (https://creativecommons.org/licenses/by-nc/4.0/), which allows for the copying and redistribution of the material only for noncommercial purposes, provided that the original work is properly cited.
Similar Articles
Evaluation of Mitral Annulus Diameter by Three-Dimensional Transesophageal Echocardiography and Its Correlation with Surgical Techniques
Akiash N, mombeini H, Keshavarz S, Sheikhi MA, Gholizadeh B, et al. Evaluation of Mitral Annulus Diameter by Three-Dimensional Transesophageal Echocardiography and Its Correlation with Surgical Techniques. Int Cardiovasc Res J. 2022;16(3):e126432. doi:
Cleft in the Anterior Mitral Valve Leaflet Assessed by Real-time 3D Echocardiography
Bezgin T, Doğan C, Karagöz A, Elveran A, Kaymaz C. Cleft in the Anterior Mitral Valve Leaflet Assessed by Real-time 3D Echocardiography. Int Cardiovasc Res J. 2016;10(2):e10282. doi:
Non-Invasive Assessment of Left Ventricular End-Diastolic Pressure in Patients with Chronic Aortic Regurgitation, Comparison of the Sensitivity and Specificity of CW Doppler Echocardiography with Angiography
Esmaeilzadeh M, Hamidzad M, Kiavar M, Bakhshandeh Abkenar H, Esmaeilzadeh F. Non-Invasive Assessment of Left Ventricular End-Diastolic Pressure in Patients with Chronic Aortic Regurgitation, Comparison of the Sensitivity and Specificity of CW Doppler Echocardiography with Angiography. Int Cardiovasc Res J. 2009;3(2):e68465. doi:
The Viable Mitral Annular Dynamics and Left Ventricular Function after Mitral Valve Repair by Biological Rings
Roshanali F, Vedadian A, Shoar S, Sandoughdaran S, Naderan M, et al. The Viable Mitral Annular Dynamics and Left Ventricular Function after Mitral Valve Repair by Biological Rings. Int Cardiovasc Res J. 2017;6(4):e12787. doi:
Evaluation of Intraoperative Saline Injection Leak Test Without Transesophageal Echocardiography as a Reliable Method During Heart Valve Repair
Heidari A, Akiash N, Moradi A, Dastoorpour M, Ahmadi F, et al. Evaluation of Intraoperative Saline Injection Leak Test Without Transesophageal Echocardiography as a Reliable Method During Heart Valve Repair. Jundishapur J Chronic Dis Care. 2024;13(4):e147055. doi: https://doi.org/10.5812/jjcdc-147055
Crossmark
Checking
- Scopus by DOI: 0
Last Update: 1 month ago
- Scopus by Title: 0
Last Update: 1 month ago
- Scopus by Title (Ref): 0
Last Update: 1 month ago
- CrossRef: 0
Last Update: 5 days ago
Ordering Reprints
Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC