Critical Appraisal and Hazards of Surface Electromyography Data Acquisition in Sport and Exercise

Authors

Jan Pieter Clarys1,*, Aldo Scafoglieri1, Jonathan Tresignie1, Thomas Reilly2, Peter Van Roy1
1Department of Experimental Anatomy (EXAN-LK), Vrije Universiteit Brussel, Belgium
2Research Institute for Sport and Exercise Sciences (RISES), Liverpool John Moores University, UK
*Corresponding Author: : Experimental Anatomy, Vrije Universiteit Brussel, Laarbeeklaan 103, 1090 Brussels, Belgium, [email protected]. Email: [email protected]

Asian Journal of Sports Medicine:Vol. 1, issue 2; 69-80
Published online:May 31, 2010
Article type:Review Article
Received:Mar 29, 2010
Accepted:May 16, 2010
How to Cite:Pieter Clarys J, Scafoglieri A, Tresignie J, Reilly T, Van Roy P. Critical Appraisal and Hazards of Surface Electromyography Data Acquisition in Sport and Exercise. Asian J Sports Med. 2010;1(2):34868. doi: https://doi.org/10.5812/asjsm.34868

Abstract

The aim of this critical appraisal and hazards of surface electromyography (SEMG) is to enhance the data acquisition quality in voluntary but complex movements, sport and exercise in particular. The methodological and technical registration strategies deal with telemetry and online data acquisition, the placement of the detection electrodes and the choice of the most adequate normalization mode.

Findings compared with the literature suggest detection quality differences between registration methods and between water and air data acquisition allowing for output differences up to 30% between registration methods and up to 25% decrease in water, considering identical measures in air and in water. Various hazards deal with erroneous choices of muscles or electrode placement and the continuous confusion created by static normalization for dynamic motion. Peak dynamic intensities ranged from 111% (in archery) to 283% (in giant slalom) of a static 100% reference. In addition, the linear relationship between integrated EMG (IEMG) as a reference for muscle intensity and muscle force is not likely to exist in dynamic conditions since it is muscle joint angle and fatigue dependent. Contrary to expectations, the literature shows 30% of non linear relations in isometric conditions also.

SEMG in sport and exercise is highly variable and different from clinical (e.g. neurological) EMG. Choices of electrodes, registration methods, muscles, joint angles and normalization techniques may lead to confusing and erroneous or incomparable results.

Full Text

Full text is available in PDF

Copyright

© 2010, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

25
Jun
2017

Good Practice Rules for the Assessment of the Force-Velocity Relationship in Isoinertial Resistance Exercises

Pietro Picerno

Picerno P. Good Practice Rules for the Assessment of the Force-Velocity Relationship in Isoinertial Resistance Exercises. Asian J Sports Med. 2017;8(3):e15590. doi: https://doi.org/10.5812/asjsm.15590

8
Dec
2019

Making EEG Experiments Retrievable for Research Purpose: The Preliminary Experience of Standardization of EEG Data in Iranian Brain Mapping Biobank

Zeynab Khodakarami,
Fattane Pourakpour,
Bahaareh Siahlou,
Parivash Pourabasi,
Shaghayegh Karimi,
Gholam Ali Hossein-Zadeh
,et al.

Khodakarami Z, Pourakpour F, Siahlou B, Pourabasi P, Karimi S, et al. Making EEG Experiments Retrievable for Research Purpose: The Preliminary Experience of Standardization of EEG Data in Iranian Brain Mapping Biobank. I J Radiol. 2019;16(Special Issue):e99163. doi: https://doi.org/10.5812/IRANJRADIOL.99163

19
Feb
2014

Assessment of Correlation between Electrogoniometer Measurements and Sports-Specific Movement in Karate Elites

Sara Lotfian,
Afsaneh Safar Cherati,
Aliashraf Jamshidi,
Mohammad Ali Sanjari

Lotfian S, Safar Cherati A, Jamshidi A, Sanjari MA. Assessment of Correlation between Electrogoniometer Measurements and Sports-Specific Movement in Karate Elites. Asian J Sports Med. 2014;5(2):23020. doi:

2
Mar
2019

Effects of fatigue on electromyography activity of biceps femoris, gastrocnemius and soleus muscles of soccer players

Alibagher Nazarian,
Amir Letafatkar,
Amirhossein Barati,
Ali Ashraf Jamshidi,
A. li Abbasi

Nazarian A, Letafatkar A, Barati A, Jamshidi AA, Abbasi AL. Effects of fatigue on electromyography activity of biceps femoris, gastrocnemius and soleus muscles of soccer players. koomesh. 2019;21(1):e153034. doi:

17
Jul
2017

Is It Time to Review our Educational Program for the Electrocardiography Operators?

Habibollah Saadat,
Hossein Tajdini,
Zahra Saadat,
Vahid Eslami,
Mehdi Sheibani,
Babak Sharifkashani
,et al.

Saadat H, Tajdini H, Saadat Z, Eslami V, Sheibani M, et al. Is It Time to Review our Educational Program for the Electrocardiography Operators?. Int J Cardiovasc Pract. 2017;2(3):e130069. doi: https://doi.org/10.21859/ijcp-020302

More by these authors

Jan Pieter ClarysPubMedScholar
Aldo ScafoglieriPubMedScholar
Jonathan TresigniePubMedScholar
Thomas ReillyPubMedScholar
Peter Van RoyPubMedScholar
Share
Cited by
Metrics