Asian Journal of Sports Medicine
Sports Medicine Research Center, TUMS
Critical Appraisal and Hazards of Surface Electromyography Data Acquisition in Sport and Exercise
Authors
Abstract
The aim of this critical appraisal and hazards of surface electromyography (SEMG) is to enhance the data acquisition quality in voluntary but complex movements, sport and exercise in particular. The methodological and technical registration strategies deal with telemetry and online data acquisition, the placement of the detection electrodes and the choice of the most adequate normalization mode.
Findings compared with the literature suggest detection quality differences between registration methods and between water and air data acquisition allowing for output differences up to 30% between registration methods and up to 25% decrease in water, considering identical measures in air and in water. Various hazards deal with erroneous choices of muscles or electrode placement and the continuous confusion created by static normalization for dynamic motion. Peak dynamic intensities ranged from 111% (in archery) to 283% (in giant slalom) of a static 100% reference. In addition, the linear relationship between integrated EMG (IEMG) as a reference for muscle intensity and muscle force is not likely to exist in dynamic conditions since it is muscle joint angle and fatigue dependent. Contrary to expectations, the literature shows 30% of non linear relations in isometric conditions also.
SEMG in sport and exercise is highly variable and different from clinical (e.g. neurological) EMG. Choices of electrodes, registration methods, muscles, joint angles and normalization techniques may lead to confusing and erroneous or incomparable results.
Copyright
© 2010, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
Good Practice Rules for the Assessment of the Force-Velocity Relationship in Isoinertial Resistance Exercises
Picerno P. Good Practice Rules for the Assessment of the Force-Velocity Relationship in Isoinertial Resistance Exercises. Asian J Sports Med. 2017;8(3):e15590. doi: https://doi.org/10.5812/asjsm.15590
Making EEG Experiments Retrievable for Research Purpose: The Preliminary Experience of Standardization of EEG Data in Iranian Brain Mapping Biobank
Khodakarami Z, Pourakpour F, Siahlou B, Pourabasi P, Karimi S, et al. Making EEG Experiments Retrievable for Research Purpose: The Preliminary Experience of Standardization of EEG Data in Iranian Brain Mapping Biobank. I J Radiol. 2019;16(Special Issue):e99163. doi: https://doi.org/10.5812/IRANJRADIOL.99163
Assessment of Correlation between Electrogoniometer Measurements and Sports-Specific Movement in Karate Elites
Lotfian S, Safar Cherati A, Jamshidi A, Sanjari MA. Assessment of Correlation between Electrogoniometer Measurements and Sports-Specific Movement in Karate Elites. Asian J Sports Med. 2014;5(2):23020. doi:
Effects of fatigue on electromyography activity of biceps femoris, gastrocnemius and soleus muscles of soccer players
Nazarian A, Letafatkar A, Barati A, Jamshidi AA, Abbasi AL. Effects of fatigue on electromyography activity of biceps femoris, gastrocnemius and soleus muscles of soccer players. koomesh. 2019;21(1):e153034. doi:
Is It Time to Review our Educational Program for the Electrocardiography Operators?
Saadat H, Tajdini H, Saadat Z, Eslami V, Sheibani M, et al. Is It Time to Review our Educational Program for the Electrocardiography Operators?. Int J Cardiovasc Pract. 2017;2(3):e130069. doi: https://doi.org/10.21859/ijcp-020302
- Scopus by DOI: 0
Last Update: 1 month ago
- Scopus by Title: 16
Last Update: 1 month ago
- Scopus by Title (Ref): 19
Last Update: 1 month ago
- CrossRef: 7
Last Update: 5 days ago