Evaluation of Mitral Annulus Diameter by Three-Dimensional Transesophageal Echocardiography and Its Correlation with Surgical Techniques

Author(s):
Nehzat AkiashNehzat AkiashNehzat Akiash ORCID1, hoda mombeinihoda mombeinihoda mombeini ORCID2,*, S.Zohreh KeshavarzS.Zohreh KeshavarzS.Zohreh Keshavarz ORCID3, Mohammad Ali SheikhiMohammad Ali SheikhiMohammad Ali Sheikhi ORCID4, Behnam GholizadehBehnam GholizadehBehnam Gholizadeh ORCID4, Ramtin Rezaee KalantariRamtin Rezaee KalantariRamtin Rezaee Kalantari ORCID4
1Atherosclerosis Research Center, Ahvaz Jundishapur University of Medical Sciences, Imam Khomeini Hospital, Ahvaz, IR Iran
2Atherosclerosis Research Center, Tehran University of Medical Sciences, Sina Hospital, Tehran, IR Iran
3General Cardiology, Ahvaz Jundishapur University of Medical Sciences, Imam Khomeini Hospital, Ahvaz, IR Iran
4Department of Cardiac Surgery, Atherosclerosis Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, IR Iran
*Corresponding Author: Atherosclerosis Research Center, Tehran University of Medical Sciences, Sina Hospital, Tehran, Iran. Cellphone: +98-9161112786, Email: [email protected].[email protected]

International Cardiovascular Research Journal:Vol. 16, issue 3; e126432
Published online:Nov 06, 2022
Article type:Research Article
Received:Apr 17, 2022
Accepted:Jul 12, 2022
How to Cite:Akiash N, mombeini H, Keshavarz S, Sheikhi MA, Gholizadeh B, et al. Evaluation of Mitral Annulus Diameter by Three-Dimensional Transesophageal Echocardiography and Its Correlation with Surgical Techniques. Int Cardiovasc Res J. 2022;16(3):e126432. doi:

Abstract

Background: Mitral Valve (MV) disease is responsible for a considerable number of open cardiac surgeries. Selecting a befitting prosthetic valve is a matter of consideration. Thus, accurate definition of mitral apparatus characteristics, particularly mitral annulus dimensions, preoperatively can shed some light on the situation. The less invasive nature of three-dimensional Transesophageal Echocardiography (3D-TEE) can turn it into a practical modality for preoperative investigation of mitral anatomy.

Objectives: The present study aimed to investigate the correlation between the size of mitral annulus attained through 3D-TEE and intraoperative size as well as the valve or ring size finally placed in mitral position.

Method: The study was conducted on 28 patients suffering from MV disease who were candidates for MV surgery. All the patients underwent 3D-TEE. Mitral annulus diameters including anteroposterior and intercommissural diameters were measured delicately by using the Mitral Valve Navigation (MVN) tool. In the midst of surgery, a mitral ring sizer was utilized in order to suggest the proper prosthesis size.

Results: The study results demonstrated that the sizer instrument was strongly associated with the inserted prosthesis size and moderately with echocardiographic annulus diameters. The correlation between the deployed prosthesis size and annulus size obtained by intraoperative sizer and 3D echocardiography was assessed, as well. The results indicated that ring sizer showed a strong positive relationship with the intercommissural echocardiography diameter and a moderate positive relationship with the anteroposterior echocardiography diameter.

Conclusion: The results revealed a good correlation between the echocardiography measurements and intraoperative examination along with the deployed prosthesis size. Thus, 3D-TEE could be considered a practical modality for the preoperative investigation of mitral anatomy.

Ā 

Ā 

Fulltext

The full-text is available in pdf.

References

  • 1.
    The references are available in pdf.

Copyright

Ā© 2022, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

31
Dec
2012

The Viable Mitral Annular Dynamics and Left Ventricular Function after Mitral Valve Repair by Biological Rings

Farideh Roshanali,
Ali Vedadian,
Saeed Shoar,
Saleh Sandoughdaran,
Mohammad Naderan,
Mohammad Hossein Mandegar

Roshanali F, Vedadian A, Shoar S, Sandoughdaran S, Naderan M, et al. The Viable Mitral Annular Dynamics and Left Ventricular Function after Mitral Valve Repair by Biological Rings. Int Cardiovasc Res J. 2017;6(4):e12787. doi:

12
Oct
2018

Advanced Technologies in the Quantification of Mitral Valve

Mersedeh Karvandi

Karvandi M. Advanced Technologies in the Quantification of Mitral Valve. Int J Cardiovasc Pract. 2018;3(3):e130267. doi: https://doi.org/10.21859/ijcp-03032

12
Nov
2022
Int J Cardiovasc Pract

Prevalence and Hemodynamic Consequences of Mitral Valve Abnormalities in Atrial Septal Defect

Maryam Shojaeifard,
Sheida Keshavari,
Saideh Jamshidi,
Hooman Bakhshandeh,
Mohammad Ali Ghaznavai,
Hossein Dehghani Mohammad Abadi
,et al.

Shojaeifard M, Keshavari S, Jamshidi S, Bakhshandeh H, Ghaznavai MA, et al. Prevalence and Hemodynamic Consequences of Mitral Valve Abnormalities in Atrial Septal Defect. Int J Cardiovasc Pract. 2021;6(2):e131707. doi: https://doi.org/10.5812/intjcardiovascpract-131707

18
Feb
2015

Are All Flexible Mitral Annuloplastic Rings the Same? An in Vivo Study

J Rasmussen

Rasmussen J. Are All Flexible Mitral Annuloplastic Rings the Same? An in Vivo Study. Multidiscip Cardio Annal. 2015;6(1):e9050. doi:

30
Sep
2012

Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults

Fatemeh Nabavizadeh,
Navin C Nanda,
Amitoj Singh,
Carmen Mateescu

Nabavizadeh F, C Nanda N, Singh A, Mateescu C. Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults. Int Cardiovasc Res J. 2017;6(3):e12811. doi:

Download PDF938.63 KB
Share on
Cited by
Metrics

Ordering Reprints

Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCCĀ 

Search Relations

Author(s):

Related Articles