Cover image of the article: Simultaneous determination of lead, cadmium, copper and zinc in Infant formula by anodic stripping voltammetry

Image Credit:Iran J Pharm Res

Simultaneous determination of lead, cadmium, copper and zinc in Infant formula by anodic stripping voltammetry

Authors

Behrooz Jannat1, Naficeh Sadeghi2,*, Mohammad Reza Oveisi2, Abdol-Azim Behfar3, Hossein Komeilizadeh4, Alireza Shafaati4
1Food and Drug Laboratory Research Center, Food and Drug Deputy, Ministry of Health and Medical Education, Tehran, Iran
2Department of Drug and Food Control, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran
3Faculty of Pharmacy, Jondishapur University of Medical Sciences, Ahvaz, Iran
4Department of Medicinal Chemistry, School of Pharmacy and Pharmaceutical Sciences Research Center (PSRC), Shahid Beheshti University (M. C.), Tehran, Iran
*Corresponding Author: Department of Drug and Food Control, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran. Email:nsadeghi@sina.tums.ac.ir

Iranian Journal of Pharmaceutical Research:Vol. 8, issue 3; 159-162
Published online:Nov 20, 2010
Article type:Research Article
Received:Apr 01, 2008
Accepted:Oct 01, 2008
How to Cite:Jannat B, Sadeghi N, Oveisi MR, Behfar A, Komeilizadeh H, et al. Simultaneous determination of lead, cadmium, copper and zinc in Infant formula by anodic stripping voltammetry. Iran J Pharm Res. 2022;8(3):e128632. doi: https://doi.org/10.22037/ijpr.2010.805

Abstract

Determination of trace elements in food is of great importance, as some of them have nutritional significance, whilst others are toxic. Long-term exposure to low levels of toxic metals could be important, especially in relation to children.

Differential Pulse Anodic Stripping Voltammetry (DPASV) is applied to simultaneous determination of lead, cadmium, copper and zinc in dry ash infant formula in nitric acid at 450±50°C.

Determination of the elements was made in acetate buffer (pH 4.7) with a scan rate of 60 mVs-1 and a pulse height of 50 mV by Hanging Mercury Dropping Electrode (HMDE). The solution was stirred during pre-electrolysis at -1150 mV (vs. Ag/AgCl) for 90 s and the potential was scanned form -1150 mV to +100 mV(vs. Ag/AgCl). Precision of the method, expressed by relative standard deviation for lead, cadmium, copper and zinc, was calculated as 4.5%, 3.5%, 3.2% and 5.6%, respectively. Under these conditions, the limits of detection were 0.005, 0.005, 0.01 and 0.05 mg/kg for lead, cadmium, copper and zinc, respectively. Concentrations of lead, cadmium, copper and zinc in one of the infant formulas available in Iran were 0.384±0.222, 0.359±0.215, 4.436±0.811 and 37.426±8.951 mg/kg (mean±SD), respectively.

In our study the concentrations of lead and copper were found significantly higher than those of standard and labelled values (P<0.001), respectively. Therefore, infant formula manufacturers, by virtue of the role of their products in the infants’ nutrition, have been acutely aware for sometime of the need to guard against any heterogeniety and contaminants.

Highlights

Copyright

© 2022, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

31
Jan
2014
Simultaneous Measurement of Zinc, Copper, Lead and Cadmium in Baby Weaning Food and Powder Milk by DPASV

Simultaneous Measurement of Zinc, Copper, Lead and Cadmium in Baby Weaning Food and Powder Milk by DPASV

Naficeh Sadeghi,
Mohammad Reza Oveisi,
Behrooz Jannat,
Mannan Hajimahmoodi,
Abdolazim Behfar,
Masoomeh Behzad
,et al.

Sadeghi N, Oveisi MR, Jannat B, Hajimahmoodi M, Behfar A, et al. Simultaneous Measurement of Zinc, Copper, Lead and Cadmium in Baby Weaning Food and Powder Milk by DPASV. Iran J Pharm Res. 2014;13(1):e125421. doi: https://doi.org/10.22037/ijpr.2014.1440

31
Dec
2019
Fabrication of a Novel Electrochemical Sensor for Simultaneous Determination of Toxic Lead and Cadmium Ions

Fabrication of a Novel Electrochemical Sensor for Simultaneous Determination of Toxic Lead and Cadmium Ions

Mehdi Sheikh Arabi,
Changiz Karami,
Masoud Ghanei-Motlagh

Sheikh Arabi M, Karami C, Ghanei-Motlagh M. Fabrication of a Novel Electrochemical Sensor for Simultaneous Determination of Toxic Lead and Cadmium Ions. Ann Mil Health Sci Res. 2019;17(4):e99082. doi: https://doi.org/10.5812/amh.99082

30
Apr
2015
Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods

Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods

Alptug Atila,
Bilal Yilmaz

Atila A, Yilmaz B. Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods. Iran J Pharm Res. 2015;14(2):e125343. doi: https://doi.org/10.22037/ijpr.2015.1649

16
Mar
2013
Measurement and Comparison of Heavy Metals Concentration in Vegetables Used in Mashhad

Measurement and Comparison of Heavy Metals Concentration in Vegetables Used in Mashhad

hossein alidadi,
zohre moghiseh,
Ali Akbar Dehghan,
Mirabootaleb Kazemi

alidadi H, moghiseh Z, Dehghan AA, Kazemi M. Measurement and Comparison of Heavy Metals Concentration in Vegetables Used in Mashhad. Zahedan J Res Med Sci. 2013;15(9):e92878. doi:

30
Apr
2018
Determinations of Melamine Residue in Infant Formula Brands Available in Iran Market Using by HPLC Method

Determinations of Melamine Residue in Infant Formula Brands Available in Iran Market Using by HPLC Method

Javad Maleki,
Firouzeh Nazari,
Jamal Yousefi,
Roya Khosrokhavar,
Mir-Jamal Hosseini

Maleki J, Nazari F, Yousefi J, Khosrokhavar R, Hosseini M. Determinations of Melamine Residue in Infant Formula Brands Available in Iran Market Using by HPLC Method. Iran J Pharm Res. 2018;17(2):e124836. doi: https://doi.org/10.22037/ijpr.2018.2231

More by these authors

Behrooz JannatPubMedScholar
Naficeh SadeghiPubMedScholar
Mohammad Reza OveisiPubMedScholar
Abdol-Azim BehfarPubMedScholar
Hossein KomeilizadehPubMedScholar
Alireza ShafaatiPubMedScholar
Share
Cited by
Metrics