Cover image of the article: Isolation and identification of Legionnaire’s disease agents from the medical equipments and environmental water sources

Image Credit:J Inflamm Dis

Isolation and identification of Legionnaire’s disease agents from the medical equipments and environmental water sources

Authors

N Khosroshahi, SM Moosavian,*
*Corresponding Author: Email: smmoosavian@mail.com

Journal of Inflammatory Diseases:Vol. 7, issue 5; 70-74
Published online:Mar 31, 2004
Article type:Research Article
How to Cite:Khosroshahi N, Moosavian S. Isolation and identification of Legionnaire’s disease agents from the medical equipments and environmental water sources. J Inflamm Dis. 2024;7(5):e155011. doi:

Abstract

Background: The legionellaceae family has a single genus legionella which is a major cause of respiratory disease in human. These agents are water – born organisms with a wide distribution in natural and artificial environmental water supplies. Transmission to human may occur through contaminated aerosols. Objective: This study was performed to isolate and identify determine the legionnaire’s disease agents from the medical equipments and environmental water sources. Methods: 210 samples were collected from hospitals and other aquatic sources in Ahwaz. The samples were examined for legionella bacteriology. Findings: The results indicated that the legionella were present in 14 out of 210 samples. Using biochemical tests, 9 serogroups of legionella species were recognized as pneumophila and the remaining 5 serogroups were reported as other legionella species. Conclusion: It seems that legionellas exist at the location of the sampling areas. Recognition of different serogroups of these bacteria needs more epidemiological studies.

Highlights

Copyright

© 2024, Journal of Inflammatory Diseases. This open-access article is available under the Creative Commons Attribution-NonCommercial 4.0 (CC BY-NC 4.0) International License (https://creativecommons.org/licenses/by-nc/4.0/), which allows for the copying and redistribution of the material only for noncommercial purposes, provided that the original work is properly cited.

Similar Articles

31
Oct
2011
Isolation and identification of legionellosis agents from fishponds, swimming pools and cooling towers in Khuzestan province, Iran

Isolation and identification of legionellosis agents from fishponds, swimming pools and cooling towers in Khuzestan province, Iran

Mojtaba Moosavian,
Amir Dashti

Moosavian M, Dashti A. Isolation and identification of legionellosis agents from fishponds, swimming pools and cooling towers in Khuzestan province, Iran. Jundishapur J Microbiol. 2011;4(4):. doi:

29
Oct
2014
Legionelle pneumophila water contamination in three military hospitals of Tehran in 2013

Legionelle pneumophila water contamination in three military hospitals of Tehran in 2013

Ali Mirmohammadlo,
Ghader Ghanizadeh,
Davoud Esmaeili,
Mojtaba Sepandi,
Peyman Avakh

Mirmohammadlo A, Ghanizadeh G, Esmaeili D, Sepandi M, Avakh P. Legionelle pneumophila water contamination in three military hospitals of Tehran in 2013. J Kermanshah Univ Med Sci. 2014;18(7):e74079. doi: https://doi.org/10.22110/jkums.v18i7.1974

6
Mar
2017
Detection of  the Legionnaires’ Disease Agent in Patients With Respiratory Symptoms by Culture, Detection of Urinary Antigen and Polymerase Chain Reaction of the 16S rRNA Gene in Ahvaz, Iran

Detection of the Legionnaires’ Disease Agent in Patients With Respiratory Symptoms by Culture, Detection of Urinary Antigen and Polymerase Chain Reaction of the 16S rRNA Gene in Ahvaz, Iran

Mojtaba Moosavian,
Mahtab Khoshkholgh Sima,
Maryam Haddadzadeh Shoushtari,
Seyed Mohammad Alavi,
Mohammad Amin Fazeli Naserabad,
Effat Abbasi Montazeri

Moosavian M, Khoshkholgh Sima M, Haddadzadeh Shoushtari M, Alavi SM, Fazeli Naserabad MA, et al. Detection of the Legionnaires’ Disease Agent in Patients With Respiratory Symptoms by Culture, Detection of Urinary Antigen and Polymerase Chain Reaction of the 16S rRNA Gene in Ahvaz, Iran. Jundishapur J Microbiol. 2017;10(4):e41611. doi: https://doi.org/10.5812/jjm.41611

18
May
2022
Detection of Legionella Pneumophila MIP and 16srRNA Genes in Kidney Transplant and Dialysis Wards by Polymerase Chain Reaction

Detection of Legionella Pneumophila MIP and 16srRNA Genes in Kidney Transplant and Dialysis Wards by Polymerase Chain Reaction

Mehrdad Ebrahimi,
Eghlim Nemati,
Davoud Esmaeili

Ebrahimi M, Nemati E, Esmaeili D. Detection of Legionella Pneumophila MIP and 16srRNA Genes in Kidney Transplant and Dialysis Wards by Polymerase Chain Reaction. Middle East J Rehabil Health Stud. 2022;9(2):e123006. doi: https://doi.org/10.5812/mejrh-123006

21
Mar
2015
Identification of Legionella Pneumophila in Intubated Patients With TaqMan Real Time PCR

Identification of Legionella Pneumophila in Intubated Patients With TaqMan Real Time PCR

Nader Divan Khosroshahi,
Taghi Naserpour Farivar,
Pouran Johari

Divan Khosroshahi N, Naserpour Farivar T, Johari P. Identification of Legionella Pneumophila in Intubated Patients With TaqMan Real Time PCR. Jundishapur J Microbiol. 2015;8(3):e15094. doi: https://doi.org/10.5812/jjm.15094

More by these authors

N KhosroshahiPubMedScholar
SM MoosavianPubMedScholar
Share
Cited by
Metrics