Journal of Inflammatory Diseases
The Official Journal of Qazvin University of Medical Sciences
Effect of mandibular plane changes on angular measurements in Cone Beam Computed Tomography
Authors
Abstract
Background: One of the most common errors in medical and dental imaging procedure is deviation from the standard position. Studies have shown that wrong positioning of the mandible during imaging by medical CT scan, can negatively affect the accuracy of linear measurements. Objectives: The aim of this study was to determine the effect of changes in angle of head on angular measurements obtained from Cone Beam Computed Tomography (CBCT) images of dried human skull. Methods: This analytical study was conducted in the School of Dentistry in Qazvin, 2011. Gutta percha markers were attached to three human skulls. The actual angles were recorded using the PLANMECA PROMAX VIEWER software. CBCT images were obtained in three positions: standard, 11 and 22 degrees axial deviation. Data were analyzed using T-test, ANOVA and Tukey. Findings: There were no significant differences between measurements obtained from CBCT in all three planes and direct measurements. There were no significant differences among the results of measurements in predetermined angles after changing the angle of dried skull in axial plane. There were no significant differences between direct measurements and CBCT measurements in separate analysis of determined angles in maxillae and mandible. Conclusion: With regards to the results, it seems that possible axial changes in head position have no effect on angular measurements in CBCT imaging and CBCT is reliable in angular measurements.
Highlights
Copyright
© 2024, Journal of Inflammatory Diseases. This open-access article is available under the Creative Commons Attribution-NonCommercial 4.0 (CC BY-NC 4.0) International License (https://creativecommons.org/licenses/by-nc/4.0/), which allows for the copying and redistribution of the material only for noncommercial purposes, provided that the original work is properly cited.
Similar Articles
Evaluating Cross-sectional Accuracy of Volumetric Calculations for Intraosseous Defects in Cone-beam Computed Tomography: Effects of Slice Intervals and Section Orientation Using Planimetry and Point Counting
Ayşe Taşyapan S, Kayıpmaz S, Ozcan İ. Evaluating Cross-sectional Accuracy of Volumetric Calculations for Intraosseous Defects in Cone-beam Computed Tomography: Effects of Slice Intervals and Section Orientation Using Planimetry and Point Counting. I J Radiol. 2025;22(1):e157224. doi: https://doi.org/10.5812/iranjradiol-157224
Accuracy of linear tomography in comparison with computed tomography to assess bone quantity for dental implant treatment
Tofangchiha M, Mohammadpour M, Shojaei fard B, Marami A, Rahrotaban S. Accuracy of linear tomography in comparison with computed tomography to assess bone quantity for dental implant treatment. J Inflamm Dis. 2024;17(6):e155805. doi:
Evaluating Diagnostic Efficacy of Cone Beam Computed Tomography Performed in Different Imaging Conditions Based on Field of View and Resolution in the Detection of Mandibular Condyle Erosions: An In Vitro Study
Sharifi Shoshtari S, Razavi M, Boostani Fard P, Rohani A, Hamidiaval S, et al. Evaluating Diagnostic Efficacy of Cone Beam Computed Tomography Performed in Different Imaging Conditions Based on Field of View and Resolution in the Detection of Mandibular Condyle Erosions: An In Vitro Study. I J Radiol. 2019;16(3):e60493. doi: https://doi.org/10.5812/iranjradiol.60493
Investigating the Effect of mA Variation on Absorbed Dose to Salivary Glands and Mandible Body in CBCT
Alirezaei Z, Jabbari K, Dehghani T, Tavakoli M, Mehdizadeh M, et al. Investigating the Effect of mA Variation on Absorbed Dose to Salivary Glands and Mandible Body in CBCT. I J Radiol. 2019;16(1):e13383. doi: https://doi.org/10.5812/iranjradiol.13383
In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT)
Fisekcioglu E, Dolekoglu S, Ilguy M, Ersan N, Ilguy D. In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT). I J Radiol. 2014;11(1):11485. doi: https://doi.org/10.5812/iranjradiol.11485
- Scopus by DOI: 0
Last Update: 1 week ago
- Scopus by Title: 0
Last Update: 1 week ago
- Scopus by Title (Ref): 1
Last Update: 1 week ago
- CrossRef: 0
Last Update: 5 days ago
- OpenAlex: 0
Last Update: 35 minutes ago
- OpenCitations: 0
Last Update: 3 days ago