In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT)

Author(s):
Erdogan FisekciogluErdogan Fisekcioglu1,*, Semanur DolekogluSemanur Dolekoglu1, Mehmet IlguyMehmet Ilguy1, Nilufer ErsanNilufer Ersan1, Dilhan IlguyDilhan Ilguy1
1Department of Dentomaxillofacial Radiology, Yeditepe University Faculty of Dentistry, Istanbul, Turkey
*Corresponding Author: Department of Dentomaxillofacial Radiology, Yeditepe University Faculty of Dentistry, Istanbul, Turkey. Tel: +90-5325626256, Fax: +90-2163636211, [email protected]. Email: [email protected]

IJ Radiology:Vol. 11, issue 1; 11485
Published online:Jan 29, 2014
Article type:Research Article
Received:Apr 09, 2013
Accepted:Jun 27, 2013
How to Cite:Fisekcioglu E, Dolekoglu S, Ilguy M, Ersan N, Ilguy D. In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT). I J Radiol. 2014;11(1):11485. doi: https://doi.org/10.5812/iranjradiol.11485

Abstract

Background:

Since the diagnosis of non-displaced longitudinal fractures present difficulties for the dentist, three-dimensional evaluation is necessary.

Objectives:

The aim of this study is to demonstrate the accuracy of cone beam computed tomography (CBCT) in detecting dental root fractures in vitro.

Materials and Methods:

An in vitro model consisting of 210 recently extracted human mandibular teeth was used. Root fractures were created by mechanical force. The teeth were placed randomly in the empty dental alveoli of a dry human mandible and 15 different dental arcs were created. Images were taken with a unit Iluma ultra cone-beam CT scanner (Imtec Corporation, Germany). Three dental radiologists separately evaluated the images.

Results:

According to the fracture types and fracture presence, there was an overall statistically significant agreement between the key and readings. Kappa values for intra observer agreement ranged between 0.705 and 0.804 indicating that each observer gave acceptable ratings for the type and presence of fractures.

Conclusions:

Detailed information about root fractures may be obtained using CBCT.

Full Text

Full text is available in PDF

Copyright

© 2014, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

22
Jul
2015

Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth

Ismail Uzun,
Kaan Gunduz,
Peruze Celenk,
Hakan Avsever,
Kaan Orhan,
Gozde Canitezer
,et al.

Uzun I, Gunduz K, Celenk P, Avsever H, Orhan K, et al. Comparing the Effect of Different Voxel Resolutions for Assessment of Vertical Root Fracture of Permanent Teeth. I J Radiol. 2015;12(3):e18290. doi: https://doi.org/10.5812/iranjradiol.18290

26
Oct
2015

Effect of Object Position in Cone Beam Computed Tomography Field of View for Detection of Root Fractures in Teeth with Intra-Canal Posts

Zahra Vasegh,
Solmaz Valizadeh,
Samin Rezapanah,
Yaser Safi,
Mohamad Javad Khaeazifard

Vasegh Z, Valizadeh S, Rezapanah S, Safi Y, Khaeazifard MJ. Effect of Object Position in Cone Beam Computed Tomography Field of View for Detection of Root Fractures in Teeth with Intra-Canal Posts. I J Radiol. 2015;12(4):e59306. doi: https://doi.org/10.5812/iranjradiol.25272

19
Nov
2019
Iranian Journal of Radiology

Effect of Artifact Reduction on the Diagnosis of Vertical Root Fracture in Teeth with Posts Using CBCT

Sima Nikneshan,
Pouria Javaheri,
Hoora Hadian

Nikneshan S, Javaheri P, Hadian H. Effect of Artifact Reduction on the Diagnosis of Vertical Root Fracture in Teeth with Posts Using CBCT. I J Radiol. 2019;16(4):e85626. doi: https://doi.org/10.5812/iranjradiol.85626

5
Jul
2016

Effect of Voxel Size on Detection of External Root Resorption Defects Using Cone Beam Computed Tomography

Sima Nikneshan,
Solmaz Valizadeh,
Anahita Javanmard,
Leila Alibakhshi

Nikneshan S, Valizadeh S, Javanmard A, Alibakhshi L. Effect of Voxel Size on Detection of External Root Resorption Defects Using Cone Beam Computed Tomography. I J Radiol. 2016;13(3):e34985. doi: https://doi.org/10.5812/iranjradiol.34985

30
Jul
2019
Iranian Journal of Radiology

Evaluating Diagnostic Efficacy of Cone Beam Computed Tomography Performed in Different Imaging Conditions Based on Field of View and Resolution in the Detection of Mandibular Condyle Erosions: An In Vitro Study

Sanaz Sharifi Shoshtari,
Mahshid Razavi,
Parisa Boostani Fard,
Ali Rohani,
Shadi Hamidiaval,
Naghme Niroomand

Sharifi Shoshtari S, Razavi M, Boostani Fard P, Rohani A, Hamidiaval S, et al. Evaluating Diagnostic Efficacy of Cone Beam Computed Tomography Performed in Different Imaging Conditions Based on Field of View and Resolution in the Detection of Mandibular Condyle Erosions: An In Vitro Study. I J Radiol. 2019;16(3):e60493. doi: https://doi.org/10.5812/iranjradiol.60493

Download PDF687.98 KB

Crossmark

Crossmark

Checking

Share on
Cited by
Metrics

Ordering Reprints

Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC 

Search Relations

Author(s):

Related Articles