Patients diagnosed with bacterial PPE in Khon Kaen Hospital, Khon Kaen, Thailand, were enrolled consecutively and prospectively. The study period was from June first, 2012 to December 31st, 2013. The inclusion criteria were patients aged > 18 years and with exudative, neutrophilic PPE. The patients were excluded if causes other than bacterial pleural effusion were suspected including the presence of lymphocytes in the pleural fluid at levels of more than 50%, the presence of abnormal cells, lung abscesses, or bloody pleural effusions (
13).
All the eligible patients signed informed consents prior to study participation. Pleural fluids of all the eligible patients were collected in blood culture bottles in addition to standard culture bottles to compare the organism identifications in both bottles. In this practice, a standard culture bottle is a sterile bottle without any media; 5 mL pleural fluid was put in both culture bottles. The bottles were transported together to the laboratory. Blood culture bottles were BacT/ALERT FA for aerobic organisms, containing soybean-casein digestive broth, sodium polyanethol sulfonate, pyridoxal HCl, menadione, hemin, activated charcoal, L-cysteine, carbohydrate, and amino acids (BioMe´rieux, Inc., Durham, N.C., USA) (
14). Blood culture bottles were used for aerobic organisms because aerobic organisms are the common pathogens in bacterial PPE (
8), and patients with pleural effusion from anaerobic pathogens were excluded. The blood culture bottles were incubated in BacT/Alert system at 35°C for seven days (
15,
16), and the procedures for BacT/Alert system were followed (
16), while pleural fluids in the standard culture bottles or sterile tubes were cultured using blood, MacConkey, and chocolate media. The organism identification procedures were similar in both groups of bottles.
Baseline patient characteristics, laboratory results, and culture results were collected and compared with the disease severity. The culture results using blood culture bottles and standard culture bottles were compared using descriptive statistics. The disease severity was classified into the most severe empyema thoracis, complicated PPE, and simple PPE as the least severity (
17). In brief, empyema thoracis is diagnosed if the pleural fluid is purulent, while complicated PPE is warranted if one of the following features is met; positive pleural fluid smears for bacterial pathogens; pleural fluid glucose < 60 mg/dL, pleural fluid pH < 7.20, or loculated pleural effusion. Simple PPE is exudative, neutrophilic pleural effusion without evidence of complicated PPE and negative pleural fluid culture by bacterial culture in both types of culture bottles.
Following Menzies et al. (
8), the proportions of the bacteria-positive pleural fluid cultures by blood culture bottles (58.5%) and standard culture bottles (37.7%) methods were used for sample size determination. The sample size was calculated by the differences of both mentioned proportions with a two-tailed, confidence level of 95%, power of 80%, and deviation of 15% by the McNamar’s method. The estimated study population was 135 subjects. The main primary outcome of the study was the comparison of the culture-positive rates between the blood culture bottles and the standard culture bottles groups. Descriptive statistics were used to calculate means, standard deviation (SD), and proportions. Comparing the proportions between the groups was performed by chi-squared or Fisher’s Exact test, when appropriate. Statistical analyses were executed by STATA 10.0 (College Station, Texas, USA).