An assessment of the factors involved in effective attenuation coefficient of the compensator material for the treatment with 6MV photons using intensity modulated radiation therapy method
Authors
Abstract
Introduction : One of the intensity modulated radiation therapy (IMRT) methods is based on using compensators. The most important factor in designing a compensator is the accurate calculation of its thickness to achieve the intensity modulation of interest. To achieve that, the exact attenuation coefficient of compensator materials must be calculated. However, there are several parameters that are effective in calculating the attenuation coefficient of compensator materials . In this research, the effects of dosimeter and phantom type as well as irradiation dose and measurement depth in the calculation of this compensator characteristic were assessed. Materials and Methods : Using two types of dosimeters (RK & FC65G) and phantoms (RFA300plus & SP34), the effects of radiation dose and measured depth on the estimation of the effective attenuation coefficient was investigated for a 6MV linear accelerator. The value of applied radiation dose was 100, 200, 300 and 400 cGy, and the measured depths were 2, 5, 10, 15 and 20 cm. The measurements were carried out at the reference field size (10×10 cm2) and for a thickness of 1 cm of the compensator. Results: The results indicated that radiation dose has no significant effect in calculating the effective attenuation coefficient of compensator materials. However, altering measured depth from 2 to 20 cm resulted in a change of more than 5% in the calculations. In addition, the type of the dosimeter and phantom used in this study had no significant effect on the calculations. Conclusion: Based on these findings, it is recommended that for more accurate estimation of the effective attenuation coefficient of a compensator material, it is necessary to measure the attenuation coefficient at different depths of the treatment field.
Copyright
© 2011, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
Determination of a medical linac wedge factor dependency on the field size, depth and separation using Monte Carlo method to introduce an algorithm for treatment planning
Hejai P, Hashemi B, Shahriari M, Eivazi M, KazemNezhad A. Determination of a medical linac wedge factor dependency on the field size, depth and separation using Monte Carlo method to introduce an algorithm for treatment planning. koomesh. 2008;10(1):e152214. doi:
Monte Carlo stimulation of the angular, radial and energy distribution of a medical linear accelerator using MCNP4C code
Hejazi P, Hashemi B, Shahriari M, KazemNezhad A. Monte Carlo stimulation of the angular, radial and energy distribution of a medical linear accelerator using MCNP4C code. koomesh. 2007;8(2):e152139. doi:
Isodose 2D determining in water phantom regular and irregular fileds in radiation therapy for caculation modulated dose
Tahmasebi Biragani MJ, Chegeni N, Zabihzade M, Arvandi S, Razmjoo Ghalaee S, et al. Isodose 2D determining in water phantom regular and irregular fileds in radiation therapy for caculation modulated dose. Jentashapir J Cell Mol Biol. 2013;4(3):e94075. doi:
Target dose enhancement factor alterations related to interaction between the photon beam energy and gold nanoparticles’ size in external radiotherapy: using Monte Carlo method
Khosravi H, Hashemi B, Mahdavi SR, Hejazi P. Target dose enhancement factor alterations related to interaction between the photon beam energy and gold nanoparticles’ size in external radiotherapy: using Monte Carlo method. koomesh. 2015;17(1):e150799. doi:
Investigating the Effect of mA Variation on Absorbed Dose to Salivary Glands and Mandible Body in CBCT
Alirezaei Z, Jabbari K, Dehghani T, Tavakoli M, Mehdizadeh M, et al. Investigating the Effect of mA Variation on Absorbed Dose to Salivary Glands and Mandible Body in CBCT. I J Radiol. 2019;16(1):e13383. doi: https://doi.org/10.5812/iranjradiol.13383
More by these authors
- Scopus by DOI: 0
Last Update: 0 months ago
- Scopus by Title: 1
Last Update: 0 months ago
- Scopus by Title (Ref): 1
Last Update: 0 months ago
- CrossRef: 0
Last Update: 1 day ago