An assessment of the factors involved in effective attenuation coefficient of the compensator material for the treatment with 6MV photons using intensity modulated radiation therapy method

Authors

Abbas Haghparast, Bijan HashemiBijan Hashemi ORCID,*, Mohammad Taghi Eyvazi
*Corresponding Author: Email: [email protected]

Koomesh:Vol. 12, issue 3; 279-184
Published online:Mar 25, 2011
Article type:Research Article
Received:Mar 30, 2010
Accepted:Nov 02, 2010
How to Cite:Haghparast A, Hashemi B, Eyvazi MT. An assessment of the factors involved in effective attenuation coefficient of the compensator material for the treatment with 6MV photons using intensity modulated radiation therapy method. koomesh. 2011;12(3):e152458. doi:

Abstract

  Introduction : One of the intensity modulated radiation therapy (IMRT) methods is based on using compensators. The most important factor in designing a compensator is the accurate calculation of its thickness to achieve the intensity modulation of interest. To achieve that, the exact attenuation coefficient of compensator materials must be calculated. However, there are several parameters that are effective in calculating the attenuation coefficient of compensator materials . In this research, the effects of dosimeter and phantom type as well as irradiation dose and measurement depth in the calculation of this compensator characteristic were assessed.   Materials and Methods : Using two types of dosimeters (RK & FC65G) and phantoms (RFA300plus & SP34), the effects of radiation dose and measured depth on the estimation of the effective attenuation coefficient was investigated for a 6MV linear accelerator. The value of applied radiation dose was 100, 200, 300 and 400 cGy, and the measured depths were 2, 5, 10, 15 and 20 cm. The measurements were carried out at the reference field size (10×10 cm2) and for a thickness of 1 cm of the compensator.   Results: The results indicated that radiation dose has no significant effect in calculating the effective attenuation coefficient of compensator materials. However, altering measured depth from 2 to 20 cm resulted in a change of more than 5% in the calculations. In addition, the type of the dosimeter and phantom used in this study had no significant effect on the calculations.   Conclusion: Based on these findings, it is recommended that for more accurate estimation of the effective attenuation coefficient of a compensator material, it is necessary to measure the attenuation coefficient at different depths of the treatment field.   

Copyright

© 2011, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

24
Oct
2008

Determination of a medical linac wedge factor dependency on the field size, depth and separation using Monte Carlo method to introduce an algorithm for treatment planning

peyman Hejai,
Bizhan Hashemi,
Majid Shahriari,
MohammadTaghi Eivazi,
Anoshiravan KazemNezhad

Hejai P, Hashemi B, Shahriari M, Eivazi M, KazemNezhad A. Determination of a medical linac wedge factor dependency on the field size, depth and separation using Monte Carlo method to introduce an algorithm for treatment planning. koomesh. 2008;10(1):e152214. doi:

15
Feb
2007

Monte Carlo stimulation of the angular, radial and energy distribution of a medical linear accelerator using MCNP4C code

Peyman Hejazi,
Bijan Hashemi,
Majid Shahriari,
Anoshiravan KazemNezhad

Hejazi P, Hashemi B, Shahriari M, KazemNezhad A. Monte Carlo stimulation of the angular, radial and energy distribution of a medical linear accelerator using MCNP4C code. koomesh. 2007;8(2):e152139. doi:

30
Jun
2013

Isodose 2D determining in water phantom regular and irregular fileds in radiation therapy for caculation modulated dose

Mohamad Javad Tahmasebi Biragani,
Nahid Chegeni,
Mansur Zabihzade,
Shole Arvandi,
Sasan Razmjoo Ghalaee,
Fatemeh Seif

Tahmasebi Biragani MJ, Chegeni N, Zabihzade M, Arvandi S, Razmjoo Ghalaee S, et al. Isodose 2D determining in water phantom regular and irregular fileds in radiation therapy for caculation modulated dose. Jentashapir J Cell Mol Biol. 2013;4(3):e94075. doi:

28
Dec
2015

Target dose enhancement factor alterations related to interaction between the photon beam energy and gold nanoparticles’ size in external radiotherapy: using Monte Carlo method

Hossein Khosravi,
Bijan Hashemi,
Seyed Rabie Mahdavi,
Payman Hejazi

Khosravi H, Hashemi B, Mahdavi SR, Hejazi P. Target dose enhancement factor alterations related to interaction between the photon beam energy and gold nanoparticles’ size in external radiotherapy: using Monte Carlo method. koomesh. 2015;17(1):e150799. doi:

18
Sep
2018
Investigating the Effect of mA Variation on Absorbed Dose to Salivary Glands and Mandible Body in CBCT

Investigating the Effect of mA Variation on Absorbed Dose to Salivary Glands and Mandible Body in CBCT

Zahra Alirezaei,
Keyvan Jabbari,
Tohid Dehghani,
Mohammadbagher Tavakoli,
Mojdeh Mehdizadeh,
Nafiseh Berenjkoob
,et al.

Alirezaei Z, Jabbari K, Dehghani T, Tavakoli M, Mehdizadeh M, et al. Investigating the Effect of mA Variation on Absorbed Dose to Salivary Glands and Mandible Body in CBCT. I J Radiol. 2019;16(1):e13383. doi: https://doi.org/10.5812/iranjradiol.13383

More by these authors

Abbas HaghparastPubMedScholar
Bijan HashemiPubMedScholar
Mohammad Taghi EyvaziPubMedScholar
Share
Cited by
Metrics