International Cardiovascular Research Journal
The Official Annually Journal of Cardiovascular Research Center, Shiraz University of Medical Sciences
Outlines
Real-time three-dimensional echocardiography: technology and clinical application
Abstract
Several studies reported during recent years showed some new possible advantages of the three-dimensional echocardiography in daily practice. Real-time three-dimensional echocardiography (RT3DE) is the only on-line 3D method based on real time volumetric scanning, as compared with other 3D imaging techniques such as computed tomography and magnetic resonance imaging, which are based on post-acquisition reconstruction and not on volumetric scanning. The aim of this study is to give a brief review of the development of the technology of RT3DE and its clinical application.
References
- 1.The references are available in PDF.
Copyright
© 2018, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
Is Three-Dimensional Echocardiography Useful in Evaluation of Atrial Septal Defects?
German C, Nanda NC. Is Three-Dimensional Echocardiography Useful in Evaluation of Atrial Septal Defects?. Int Cardiovasc Res J. 2017;9(2):e11297. doi:
Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults
Nabavizadeh F, C Nanda N, Singh A, Mateescu C. Live/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults. Int Cardiovasc Res J. 2017;6(3):e12811. doi:
The Role of Three-Dimensional Imaging in the Control of Intrauterine Contraceptive Devices
Ahmadi F, Haghighi H. The Role of Three-Dimensional Imaging in the Control of Intrauterine Contraceptive Devices. I J Radiol. 2015;12(2):e59261. doi: https://doi.org/10.5812/iranjradiol.8499
Evaluation of Mitral Annulus Diameter by Three-Dimensional Transesophageal Echocardiography and Its Correlation with Surgical Techniques
Akiash N, mombeini H, Keshavarz S, Sheikhi MA, Gholizadeh B, et al. Evaluation of Mitral Annulus Diameter by Three-Dimensional Transesophageal Echocardiography and Its Correlation with Surgical Techniques. Int Cardiovasc Res J. 2022;16(3):e126432. doi:
Evaluation of basic parameters of real-time diagnostic ultrasound systems
Manteghi F, Ashrafi A, Mokhtari M. Evaluation of basic parameters of real-time diagnostic ultrasound systems. koomesh. 2004;5(1):e151997. doi:
- Scopus by DOI: 0
Last Update: 0 months ago
- Scopus by Title: 0
Last Update: 0 months ago
- Scopus by Title (Ref): 0
Last Update: 0 months ago
- CrossRef: 0
Last Update: 5 days ago
Ordering Reprints
Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC
Author(s):