Chemicals
Pesticides reference standards (purity > 96.0%), triphenylphosphate (TTP), as internal standard and anhydrous magnesium sulfate (MgSO4), were purchased from Sigma–Aldrich /Fluka /Riedel-de-Haën (Germany). Ammonium formate, methanol (MeOH) and HPLC-grade acetonitrile (MeCN) were purchased from Across (Belgium). Ethyl acetate (EtAc), glacial acetic acid (HOAc) and sodium acetate were supplied from Merck (Darmstadt, Germany). Bondesil-primary secondary amine (PSA, 40 μm) was provided from Interchim (France). HPLC grade water was obtained by purifying demineralized water on a Milli-Q Plus ultra-pure water system (Millipore, Molsheim, France).
Individual stock solutions of the pesticides at a concentration of 1000 μg/mL were prepared in ethyl acetate and methanol (Cartap and Fuberidazole) according to their solubility at 20
◦C. A mixed intermediate standard solution at a concentration of 5 μg/mL was prepared via appropriate dilution of the stock solutions in MeOH containing 0.1% HOAc in order to avoid the degradation of the pesticides (
8). This solution was used as a spiking solution for validation experiments. Matrix-matched multi-level calibration standards solutions were prepared in sample extracts obtained from organic rice. Aliquots of blank samples (5 mL of final MeCN layer), which were extracted via QuEChERS method were evaporated and reconstituted in 5 mL of mixture of appropriate working standard solutions and 0.02% HOAc in MeOH to generate final concentrations of 0.02, 0.04, 0.10, 0.20, 0.50 and 1.0 μg/g for the matrix-matched calibration standards. A stock solution of triphenylphosphate (TTP) in ethyl acetate at concentration of 20 μg/mL was used as internal standard and an aliquot of 50 μL of TTP solution in ethyl acetate (20 μg/mL) was added to the spiked rice sample as internal standard.
Pesticide selection
The 18 selected LC-amenable pesticides (carbaryl, cartap, chlorpyrifos, cinosulfuron, diazinon, edifenphos, malathion, oxadiazon, oxydemeton-methyl, primiphos-methyl, propiconazole, spynosin A and D, thiobencarb, thiophanate-methyl, triadimenol, tricyclazole, triflumizole) are used for rice production in Iran and MRL
s have been established for them by Institute of Standards and Industrial Research of Iran (ISIRI), NO.13120 (
5). According to the same act some of pesticides are forbidden to use in Iran. Existence of banned pesticides in any kind of food including rice can produce health problems and it is necessary to investigate the presence of them in foods. Therefore, 23 banned LC-amenable pesticides according to ISIR̕s list (
5), including; azinphos-ethyl, bromacil, carbofuran, chlorbromuron, chlorfenvinphos, coumaphos, dialifos, dicrotophos, etrimfos, fluometuron fuberidazole, iprobenfos, methabenzthiazuron, methidathion, monocrotophos, omethoate, phosphamidon, phoxim, propoxur, pyrazophos, TCMTB, tri-allate, triazophos were selected.
The comprehensive list covers 41 pesticides with different modes of action such as herbicides, fungicides, insecticides and plant growth regulators with different chemical natures such as organophosphates, carbamates, micro-organism derived (Spinosyn), strobilurins and quarternary ammoniums.
Rice samples
Sixty rice samples, including 30 domestic and 30 imported samples were collected from different regions of Tehran in early six months of 1388 (March 23- September 23, 2009). A 100 grams portion of the collected samples were grinded with 100 g dry ice, right after purchase and stored in -70 °C until analysis.
Liquid chromatography
The separation of the different pesticides from the samples was carried out using an Alliance separations module 2695 (Waters, Milford, MA, USA), which consist of a quaternary solvent delivery system, degasser, autosampler, column heater and diode array detector coupled with a Quattro Micro Triple Quadrupole LC/MS (Waters, Micromass, Manchester, UK).
Chromatographic separation was performed using an Agilent ZORBAX Eclipse XDB-C18 (Narrow-Bore 2.1×150 mm, 3.5-micron) analytical column at a flow rate of 200 μL/min and an injection volume of 100 μL. The mobile phase was 5 mM in methanol (solvent A) and 5 mM ammonium formate in water (solvent B) in a ammonium formate gradient mode and a total analysis time of 30 min. The elution program was as follows: at the start 30% solvent A and 70% solvent B; the percentage of solvent A was linearly increased to 100% in 20 min, then remained constant for 5 minand ramped to original composition in 5 min. The temperature of the column heater was maintained at 40 °C.
Mass spectrometry
The MS/MS system consisted of a triple quadrupole mass spectrometer Quattro Micro (Waters-Micromass, UK) equipped with an electrospray source (Z-spray) and operated in positive ionization mode. Mass Lynx software, version 4.0, was used for instrument control and data acquisition. Analysis was performed in positive ion mode. The ESI source values were: capillary voltage, 4.12 kV; extractor, 2 V; RF lens, 0.1 V; source temperature, 120 ◦C; desolvation temperature, 300 °C; desolvation gas and cone gas (nitrogen 99.99% purity) flow rates, 500 and 50 L/h, respectively. The analyzer settings were: resolution, 14.6 (unit resolution) for LM1 and LM2 resolution and 14 for HM1 and HM2 resolution; ion energy1 and 2, 0.3 and 3.0, respectively; entrance and exit energies, 55 and 75 (V); multiplier, 700 (V); collision as (argon, 99.995%) pressure 5.35 × 10-3 mbar.
Sample preparation
Extraction was performed by the original QuEChERS method (
12). Five g of homogenized rice sample was accurately weighed into a 50 mL centrifuge tube. Appropriate concentrations of the mixed working standard solution (for spiking) and internal standard were added to the tube and 10 mL of acetonitrile (MeCN) was added. The mixture was vortex mixed for 2.0 min, followed by addition of a mixture of 2 g anhydrous MgSO
4 and 1.5 g sodium acetate and vortex mixing for 2.0 min again. The mixture was centrifuged for 5 min at 5433×g, and 5 mL of the supernatants was then transferred into an appropriate tube containing 100 μL methanol (MeOH) placed in a nitrogen evaporator and evaporated at 40 °C until dryness.The residue was reconstituted in 5 mL MeCN. The mixture was vortex mixed for 2.0 min followed by sonication for 4.0 min and the solution was transferred to atube containing 60 mg anhydrous MgSO
4 and 20 mg PSA (primary secondary amine). The mixture was vortex mixed vigorously for 2 min and centrifuged for 5 min at 5433×g. Finally, a 5 mL aliquot of the cleaned extract was transferred into a screw cap vial and 100μL of the solution was injected into LC-MS/MS.
Method validation
The validation study was performed based on the European SANCO guidelines (
24). The method was tested to assess for sensitivity, mean recovery, precision, and limit of quantification (LOQ). This requires performing recovery experiments with spiked blank samples to estimate the accuracy of the method. A minimum of 5 replicates is required (to check the precision) at both the reporting limit (to check the sensitivity of the method), and at least another higher level.
Linearity was studied using matrix-matched calibrations by analyzing in triplicate six concentration levels, between 0.01 and 1.0 μg/g.
For determination of mean recoveries and precision (repeatability, expressed as coefficient of variation (in %), five spiked blank rice samples at concentration levels of 0.025, 0.08 and 0.250 μg/g were prepared and then treated according to the procedure described in sample preparation. The recoveries were calculated using the matrix-matched calibration.
The limit of quantification (LOQ) was established as the lowest validated spike level meeting the method performance acceptability criteria (mean recoveries for each representative commodity in the range 70-120%, with an RSD ≤ 20%).
The concentrations of pesticides were determined by interpolation of the relative peak areas for each pesticide to internal standard peak area in the sample on the spiked calibration curve. In order to compensate for losses during sample processing and instrumental analysis, internal standard (TPP) was used.