Cover image of the article: Misplaced Central Venous Catheter in the Left Hemiazygos Vein; A Case Report

Image Credit:Int Cardiovasc Res J

Misplaced Central Venous Catheter in the Left Hemiazygos Vein; A Case Report

Authors

Najmeh Zarei JelyaniNajmeh Zarei Jelyani ORCID1, Razieh Sadat Mousavi-RoknabadiRazieh Sadat Mousavi-Roknabadi ORCID1, 2,*
1Department of Emergency Medicine, School of Medicine, Shiraz University of Medical Sciences, Shiraz, IR Iran
2Emergency Medicine Research Center, Shiraz University of Medical Sciences, Shiraz, IR Iran
*Corresponding Author: School of Medicine, Shiraz University of Medical Sciences, Nemazee Hospital, Postal Code: 71937-11351, Shiraz, Iran. Tel: +98-9131563018, Email: mousavi_razieh@sums.ac.ir.mousavi_razieh@sums.ac.ir

International Cardiovascular Research Journal:Vol. 15, issue 2; e108483
Published online:Jun 30, 2021
Article type:Case Report
Received:Sep 11, 2020
Accepted:Nov 14, 2020
How to Cite:Zarei Jelyani N, Mousavi-Roknabadi RS. Misplaced Central Venous Catheter in the Left Hemiazygos Vein; A Case Report. Int Cardiovasc Res J. 2021;15(2):e108483. doi:

Abstract

Introduction:
The structure of the hemiazygos vein is often different in different individuals There is a normal variation that connects the ascending hemiazygos vein to the left innominate vein, parallel with the subclavian and internal jugular veins.
Case Presentation:
A 33-year-old man who was a known case of End Stage Renal Disease (ESRD) was admitted to the emergency department due to Double Lumen (DL) dysfunction. The emergency physician inserted DL in his left jugular vein on the ultrasound guide. The result of angiography showed that DL was placed in his left hemiazygos vein.
Conclusions:
This condition should be considered as part of the anatomical variation of the left hemiazygos vein during DL insertion by emergency physicians.
 

Highlights

Fulltext

The full-text is available in pdf.

References

  • 1.
    The references are available in pdf.

Copyright

© 2021, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

1
Mar
2022
A Variation of Azygos Venous System with Absence of Hemiazygos and Accessory Hemiazygos Veins: A Case Report

A Variation of Azygos Venous System with Absence of Hemiazygos and Accessory Hemiazygos Veins: A Case Report

Mohsen Eslami Farsani,
Reihaneh Seyedebrahimi,
Shima Ababzadeh,
Maasoume Abdollahi,
Fatemeh Heidari

Eslami Farsani M, Seyedebrahimi R, Ababzadeh S, Abdollahi M, Heidari F. A Variation of Azygos Venous System with Absence of Hemiazygos and Accessory Hemiazygos Veins: A Case Report. Int Cardiovasc Res J. 2022;16(1):e121073. doi:

3
Jul
2018
Endovascular Management of Iatrogenic Internal Jugular Vein-Subclavian Artery Fistula Formed by Inadvertently Misplaced Hemodialysis Catheter: A Case Report

Endovascular Management of Iatrogenic Internal Jugular Vein-Subclavian Artery Fistula Formed by Inadvertently Misplaced Hemodialysis Catheter: A Case Report

Mohammad Gharib Salehi,
Alireza Rai,
Mohammadreza Sobhiyeh,
Elham Shobeiri

Salehi MG, Rai A, Sobhiyeh M, Shobeiri E. Endovascular Management of Iatrogenic Internal Jugular Vein-Subclavian Artery Fistula Formed by Inadvertently Misplaced Hemodialysis Catheter: A Case Report. I J Radiol. 2018;15(4):e57936. doi: https://doi.org/10.5812/iranjradiol.57936

5
Feb
2014
A Rare Central Venous Catheter Malposition: A Case Report

A Rare Central Venous Catheter Malposition: A Case Report

Ali Asghar Moeinipour,
Ahmad Amouzeshi,
Marjan Joudi,
Mehdi Fathi,
Saeed Jahanbakhsh,
Saeed Hafez
,et al.

Moeinipour AA, Amouzeshi A, Joudi M, Fathi M, Jahanbakhsh S, et al. A Rare Central Venous Catheter Malposition: A Case Report. Anesth Pain Med. 2014;4(1):e16049. doi: https://doi.org/10.5812/aapm.16049

22
Apr
2015
Retro-Aortic Inverted Left Renal Vein: A Rare Anomaly Found in a Renal Donor

Retro-Aortic Inverted Left Renal Vein: A Rare Anomaly Found in a Renal Donor

Sofia Sabouri,
Ashrafsadat Hosseini,
Seyedeh Shirin Shivaei

Sabouri S, Hosseini A, Shivaei SS. Retro-Aortic Inverted Left Renal Vein: A Rare Anomaly Found in a Renal Donor. I J Radiol. 2015;12(2):e11374. doi: https://doi.org/10.5812/iranjradiol.11374

30
Nov
2018
Suspected Short Peripheral Venous Catheter Intravascular Embolization: Identification and Management

Suspected Short Peripheral Venous Catheter Intravascular Embolization: Identification and Management

Limael E Rodriguez,
Francisco Steven Rodriguez,
Francisco J Rivera-Pedrogo

E Rodriguez L, Steven Rodriguez F, J Rivera-Pedrogo F. Suspected Short Peripheral Venous Catheter Intravascular Embolization: Identification and Management. Int J Cardiovasc Pract. 2018;3(4):e130272. doi: https://doi.org/10.21859/ijcp-03044

More by these authors

Najmeh Zarei JelyaniPubMedScholar
Razieh Sadat Mousavi-RoknabadiPubMedScholar
Share
Cited by
Metrics