Cover image of the article: Seizure following removal of Swan Ganz Catheter

Image Credit:J Cell Mol Anesth

Seizure following removal of Swan Ganz Catheter

Authors

Alireza JahangirifardAlireza Jahangirifard ORCID1,*, SeyedBashir MirtajaniSeyedBashir Mirtajani ORCID2, Behrooz Farzanegan3, Alireza JahangirifardAlireza Jahangirifard ORCID4, Zargham Hossein Ahmadi5
1Chronic Respiratory Disease Research Center, National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran.
2Mycobacteriology Research Center (MRC), National Research Institute of Tuberculosis and Lung Disease (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran.
3Tracheal Diseases Research Center, National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences ,Tehran ,Iran.
4Masih Deveshvari Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
5Lung transplant Research Center, National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran.
*Corresponding Author: Chronic Respiratory Disease Research Center, National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran. Email: alirezajahangiri@sbmu.ac.ir

Journal of Cellular & Molecular Anesthesia:Vol. 5, issue 3; e149616
Published online:May 02, 2020
Article type:Case Report
How to Cite:Jahangirifard A, Mirtajani S, Farzanegan B, Jahangirifard A, Ahmadi ZH. Seizure following removal of Swan Ganz Catheter. J Cell Mol Anesth. 2020;5(3):e149616. doi: https://doi.org/10.22037/jcma.v5i3.29984

Abstract

Venous air embolism (VAE) is an infrequent incident with fatal consequences during insertion or removal of central venous catheters. It is befalling when air or gas arrives at the vascular system. In this case report, we present a case of a 38-year-old female patient with an air embolism after removal of the Swan Ganz catheter that caused the seizure and cardiac arrest. There is an overview of the causes and ways to prevent VAE in the patient

Highlights

References

  • 1.
    References are in the PDF file of the article.

Copyright

© 2020, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

23
Oct
2016
Unexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report

Unexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report

Naomi Ono,
Junko Nakahira,
Sayuri Matsunami,
Toshiyuki Sawai,
Toshiaki Minami

Ono N, Nakahira J, Matsunami S, Sawai T, Minami T. Unexpected Collection of Pulmonary Venous Blood from a Pulmonary Artery Catheter: A Case Report. Anesth Pain Med. 2016;6(6):e42621. doi: https://doi.org/10.5812/aapm.42621

30
Nov
2018
Suspected Short Peripheral Venous Catheter Intravascular Embolization: Identification and Management

Suspected Short Peripheral Venous Catheter Intravascular Embolization: Identification and Management

Limael E Rodriguez,
Francisco Steven Rodriguez,
Francisco J Rivera-Pedrogo

E Rodriguez L, Steven Rodriguez F, J Rivera-Pedrogo F. Suspected Short Peripheral Venous Catheter Intravascular Embolization: Identification and Management. Int J Cardiovasc Pract. 2018;3(4):e130272. doi: https://doi.org/10.21859/ijcp-03044

7
Sep
2014
Letter to Editor on a Rare Central Venous Catheter Malposition

Letter to Editor on a Rare Central Venous Catheter Malposition

Jason Lie,
Manjula Yadagiri,
Catherine Aspinall

Lie J, Yadagiri M, Aspinall C. Letter to Editor on a Rare Central Venous Catheter Malposition. Anesth Pain Med. 2014;4(4):e20019. doi: https://doi.org/10.5812/aapm.20019

31
Oct
2017
Successful Detachable Coil Embolization of Iatrogenic Superior Vena Cava Penetration by Central Venous Catheter: A Case Report

Successful Detachable Coil Embolization of Iatrogenic Superior Vena Cava Penetration by Central Venous Catheter: A Case Report

Byung Jin Park,
Jae Kyu Kim,
Hyoung Ook Kim,
Nam Yeol Yim,
Yang Jun Kang

Jin Park B, Kyu Kim J, Ook Kim H, Yeol Yim N, Jun Kang Y. Successful Detachable Coil Embolization of Iatrogenic Superior Vena Cava Penetration by Central Venous Catheter: A Case Report. I J Radiol. 2017;14(4):e63481. doi: https://doi.org/10.5812/iranjradiol.63481

13
Feb
2016
Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization

Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization

Agrawal Amit,
Shrivastava Jyotsna,
Vinay Kumar Kasyap

Amit A, Jyotsna S, Kumar Kasyap V. Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization. J Compr Ped. 2016;7(1):e33238. doi: https://doi.org/10.17795/compreped-33238

More by these authors

Alireza JahangirifardPubMedScholar
SeyedBashir MirtajaniPubMedScholar
Behrooz FarzaneganPubMedScholar
Alireza JahangirifardPubMedScholar
Zargham Hossein AhmadiPubMedScholar
Share
Cited by
Metrics
Indexed in