Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma

Author(s):
Neda AdibpourNeda Adibpour1, Maryam AhmadnasrMaryam Ahmadnasr2, Mohammad Javad KhodayarMohammad Javad Khodayar3, Saeed RezaeeSaeed Rezaee2,*
1Department of Medicinal Chemistry, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, IR Iran
2Department of Pharmaceutics, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, IR Iran
3Department of Pharmacology and Toxicology, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, IR Iran
*Corresponding Author: Department of Pharmaceutics, School of Pharmacy, Ahvaz Jundishapur University of Medical Sciences, [email protected], IR Iran. Tel: +98-6113738378. Fax: +98-6113738381. Email: [email protected]

Jundishapur Journal of Natural Pharmaceutical Products:Vol. 8, issue 2; 81-85
Published online:May 03, 2013
Article type:Research Article
Received:Oct 27, 2012
Accepted:Dec 18, 2012
How to Cite:Adibpour N, Ahmadnasr M, Khodayar MJ, Rezaee S. Development and Validation of a High-Performance Liquid Chromatography Method With UV Detection for Determination of 1-(2-phenylethyl)-5- (quinaldin-4-yl) Biuret in Rat Plasma. Jundishapur J Nat Pharm Prod. 2013;8(2):. doi: https://doi.org/10.17795/jjnpp-8823

Abstract

Background:

Recently, biuret derivatives have been reported as showing moderate to good cytotoxic effect against certain cancer cell lines. In this study, a high-performance liquid chromatography method was developed for determination of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret (PEQB) in rat plasma to use in future studies on this compound and related derivatives.

Objectives:

In this study, we describe a simple and sensitive high-performance liquid chromatography method with UV detection for determination of 1-(2-phenylethyl)-6-(quinaldin-4-yl) biuret (PEQB) in rat plasma.

Materials and Methods:

Separations were performed on a Nucleosil-100 CN HPLC column (125 4.0 mm) (5 m), using a mixture of acetonitrile: methanol: potassium dihydrogen phosphate buffer (0.05 M, pH 3.5) (10:10:80) as mobile phase delivered at a flow rate of 1 mL/minute. Detection of PEQB and internal standard (1-([[3-(1,3-benzothiazol-2-ylsulfanyl)propyl]carbamoyl]amino)-N-phenylformamide) was performed at 235 nm and ambient temperature. Plasma samples (200 L) were prepared by addition of 40 L internal standard (100 g/mL), and 400 L acetonitrile. After vortex mixing and centrifugation at 10000 g, 50 L of the clear supernatant was directly injected onto the chromatography column. Calibration curves were constructed by fitting the peak area ratio of the biuret to internal standard against concentration of biuret to a power model using generalized least squares nonlinear regression method.

Results:

Under the above chromatography condition, biuret compound (PEQB) and the internal standard were detected at 4.5 and 13.5 minutes, respectively. Limit of quantitation of the PEQB was 0.1 g/mL. Accuracy of the method over the concentration range of 0.1-100 g/mL was between 88-109%. Inter- and intraday precisions were 4-19% and 6-8%, respectively. A good relationship in the form of a power model was found for two separate concentration ranges of 0.1-1 and 2.5-100 g/mL (R 2> 0.99).

Conclusions:

The presented simple HPLC method is sufficiently accurate, precise and sensitive for the quantitation of 1-(2-phenylethyl)-5-(quinaldin-4-yl) biuret in rat plasma.

Full Text

Full text is available in PDF

Copyright

© 2013, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

20
Nov
2010

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

Mohsen Amini,
Mahnaz Khanavi,
Abbas Shafiee

Amini M, Khanavi M, Shafiee A. Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma. Iran J Pharm Res. 2022;3(2):e128189. doi: https://doi.org/10.22037/ijpr.2010.583

30
Apr
2014

Simple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples

Mohammad Charehsaz,
Aylin Gürbay,
Ahmet Aydin,
Gönül Şahin

Charehsaz M, Gürbay A, Aydin A, Şahin G. Simple, Fast and Reliable Liquid Chromatographic and Spectrophotometric Methods for the Determination of Theophylline in Urine, Saliva and Plasma Samples. Iran J Pharm Res. 2014;13(2):e125529. doi: https://doi.org/10.22037/ijpr.2014.1510

30
Apr
2016

Simultaneous Determination of Six Benzodiazepines in Spiked Soft Drinks by High Performance Liquid Chromatography with Ultra Violet Detection (HPLC-UV)

Kambiz Soltaninejad,
Mohammad Karimi,
Alireza Nateghi,
Bahram Daraei

Soltaninejad K, Karimi M, Nateghi A, Daraei B. Simultaneous Determination of Six Benzodiazepines in Spiked Soft Drinks by High Performance Liquid Chromatography with Ultra Violet Detection (HPLC-UV). Iran J Pharm Res. 2016;15(2):e125201. doi: https://doi.org/10.22037/ijpr.2016.1863

30
Apr
2010

High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies

Hossein Amini,
Abolhassan Ahmadiani

Amini H, Ahmadiani A. High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies. Iran J Pharm Res. 2010;9(2):e126070. doi: https://doi.org/10.22037/ijpr.2010.845

31
Oct
2019

Simultaneous Determination of Isoniazid, Pyrazinamide and Rifampin in Human Plasma by High-performance Liquid Chromatography and UV Detection

Behnam Dasht Bozorg,
Ali Goodarzi,
Fanak Fahimi,
Payam Tabarsi,
Nahid Shahsavari,
Farzad Kobarfard
,et al.

Dasht Bozorg B, Goodarzi A, Fahimi F, Tabarsi P, Shahsavari N, et al. Simultaneous Determination of Isoniazid, Pyrazinamide and Rifampin in Human Plasma by High-performance Liquid Chromatography and UV Detection. Iran J Pharm Res. 2019;18(4):e124712. doi: https://doi.org/10.22037/ijpr.2019.1100849

Download PDF880.74 KB

Crossmark

Crossmark

Checking

Share on
Cited by
Metrics

Ordering Reprints

Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC 

Search Relations

Author(s):

Related Articles