Using Optimal Projections for Reduction of Radiation Risks in Some Radiographies

Author(s):
Ali ChaparianAli Chaparian1,*, Abolfazl KananiAbolfazl Kanani2
1Department of Medical Physic, Shahid Sadoughi University of Medical Sciences, Yazd, IR Iran
2Department of Nuclear Engineering, University of Isfahan, Isfahan, IR Iran

Published online:Feb 28, 2014
Article type:Research Article
How to Cite:Chaparian A, Kanani A. Using Optimal Projections for Reduction of Radiation Risks in Some Radiographies. I J Radiol. 2014;11(30th Iranian Congress of Radiology):e21288. doi: https://doi.org/10.5812/iranjradiol.21288

Abstract

Background:

While modern nonionizing imaging systems such as magnetic resonance imaging offer undeniable advantages including lack of radiation and better image quality, the availability and lower cost of conventional X-ray examinations make them remain a cornerstone of diagnosis. While being highly helpful in the diagnosis of diseases, radiological examinations may involve potential risks. One of the most efficient dose reducing methods requiring no additional cost is the use of optimized projections instead of the traditionally accepted projections.

Objectives:

The goals of the present study were the calculation and comparison of the effective doses and the risks of exposure induced cancer in male and female patients for different projections of the abdomen, the pelvis, and the lumbar spine X-ray examinations.

Patients and Methods:

Radiographies of lumbar spine [in the eight projections of anteroposterior (AP), posteroanterior (PA), right lateral (RLAT), left lateral (LLAT), right anterior-posterior oblique (RAO), left anterior-posterior oblique (LAO), right posterior-anterior oblique (RPO), and left posterior-anterior oblique (LPO)], abdomen (in the two projections of AP and PA), and pelvis (in the two projections of AP and PA) were investigated. A solid-state dosimeter was used for the measurement of skin exposure. A Monte Carlo program was used for calculation of effective doses and the risks of radiation-induced cancer related to the different projections.

Results:

Results of this study showed that PA projection of abdomen, lumbar spine, and pelvis radiographies caused 50%-57% lower effective doses than AP projection and a 50%-60% reduction in radiation risks. Also, the use of LAO projection in lumbar spine X-ray examination caused 53% lower effective dose than RPO projection and 56% and 63% reduction in radiation risk for male and female patients respectively. Furthermore, RAO projection caused a 28% lower effective dose than LPO projection and 52% and 39% reduction in radiation risk for male and female patients respectively.

Conclusions:

Results of this study may introduce preferable projections for reduction of the effective dose and the risk of radiation-induced cancer. Recommended projection, whenever possible, for abdomen and pelvis X-ray examinations should be the PA projection rather than AP projection. Also, suggested projections for lumbar spine radiography should be PA rather than AP, LAO rather than RPO, RAO rather than LPO, and for men, RLAT rather than LLAT.

Full Text

Full text is available in PDF

Similar Articles

23
Jan
2016

Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography

Jung-Su Kim,
Sang-Wook Yoon,
Deok-Nam Seo,
So-Ra Nam,
Jung-Min Kim

Kim J, Yoon S, Seo D, Nam S, Kim J. Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography. I J Radiol. 2016;13(1):e22514. doi: https://doi.org/10.5812/iranjradiol.22514

30
Dec
2003

Reduction of Unwarranted Patient Exposure in X-ray Examinations  

F. Bouzarjomehri

Bouzarjomehri F. Reduction of Unwarranted Patient Exposure in X-ray Examinations  . I J Radiol. 2003;1(3&4):e79266. doi:

28
Dec
2015

Dosimetry of organ at risks in Orthopantomography

Mehravar Rafati,
Amir Eftekhari-Moghadam,
Ghazal Mehri-Kakavand,
Hadi Hasanzadeh,
Afsaneh Maftoon

Rafati M, Eftekhari-Moghadam A, Mehri-Kakavand G, Hasanzadeh H, Maftoon A. Dosimetry of organ at risks in Orthopantomography. koomesh. 2015;17(1):e150800. doi:

12
Jun
2018
Common Diagnostic Radiology Procedures, Academic Radiology

Cumulative Radiation Dose and Cancer Risk Estimation in Common Diagnostic Radiology Procedures

Safoora Nikzad,
Maryam Pourkaveh,
Naghi Jabbari Vesal,
Farideh Gharekhanloo

Nikzad S, Pourkaveh M, Jabbari Vesal N, Gharekhanloo F. Cumulative Radiation Dose and Cancer Risk Estimation in Common Diagnostic Radiology Procedures. I J Radiol. 2018;15(3):e60955. doi: https://doi.org/10.5812/iranjradiol.60955

7
Sep
2016

Comparison of Radiation Dose and Image Quality with Various Computed-Tomography Scout Views: The Angular Modulation Technique Based on Information Calculated from Scout Views

Myeong Seong Kim,
Jong-Woong Lee,
Sun Geun Kim,
Dae Cheol Kweon

Seong Kim M, Lee J, Geun Kim S, Cheol Kweon D. Comparison of Radiation Dose and Image Quality with Various Computed-Tomography Scout Views: The Angular Modulation Technique Based on Information Calculated from Scout Views. I J Radiol. 2017;14(1):e13477. doi: https://doi.org/10.5812/iranjradiol.35606


Crossmark
Crossmark
Checking
Share on
Cited by
Metrics

Ordering Reprints

Articles are published under the Creative Commons license stated on each article. No permission or royalty fee is required for uses permitted by that license. CCC handles optional bulk and customized reprint orders. Any quotation covers production and delivery services only, not copyright permission. > Request Reprints from CCC