An Innovative Journal in the Field of Radiology
Assessment the Possibility of Radiation Dermatitis Incidence in the Interventionist’s Leg
Authors
Abstract
Background: Fluoroscopy guided imaging, which is going to be more routine these days require a long time of fluoroscopic observing, which can increase the radiation dose of the physician and other staff who have to stay near the patient during the procedure. In our department, one of the senior interventionists had observed the hair loss in his lower limb. Thus the objective of this study was measuring the radiation dose of the physician’s leg during common procedures in order to find out that whether the radiation dose exceeds the threshold of deterministic effects of radiation or not?.
Methods: Thermo luminescent-dosimeters (TLD-100) set on the leg part of the anthropomorphic whole body phantom PBU-50, was used in order to measure the radiation dose in 2 centers where our interventionist work. Meanwhile, the duration of exposure in important procedures was observed and recorded in center 1 for 2 months. During this period some data such as age, height, and weight of the patients and radiation exposure time, dose (mGy) and dose area product (dap) (Gy.cm2) was recorded
Results: The result of TLD dosimetry shown that the mean effective dose in center 1 and 2 was 0.20 and 0.86 mSv, and also the mean-dose (mSv)/min in these centers was 0.02 ± 0.00 and 0.20 ± 0.015 mSv/min respectively.
Conclusions: The effective annual dose of interventionists who work in center 1 and 2 was 143.08 and 1226.78 mSv respectively. The high radiation dose which delivers to the leg of physicians in center 2 can be an important cause of radiation dermatitis occurred on the leg of our interventionist. Patient dose during most of the procedures was less than the threshold dose for occurring erythema but unfortunately in TIPS procedure which is a time-consuming procedure the patient radiation dose exceeds the threshold. It would be useful if a plan design to reduce the dose of patients and even physicians.
Highlights
Copyright
© 2017, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
Assessment of the Possibility of Radiation Dermatitis in the Legs of Interventional Radiologists
Zarei F, Zeinali-Rafsanjani B, Saeedi-Moghadam M, Rasekhi A, Abolhasani Foroughi A. Assessment of the Possibility of Radiation Dermatitis in the Legs of Interventional Radiologists. I J Radiol. 2017;14(3):e22030. doi: https://doi.org/10.5812/iranjradiol.22030
Evaluation of Occupational and Patient Dose in Challenging Hemodialysis Catheter Placement
Rasekhi A, Abolhasani Foroughi A, Zeinali-Rafsanjani B, Saeedi-Moghadam M, Zarei F, et al. Evaluation of Occupational and Patient Dose in Challenging Hemodialysis Catheter Placement. I J Radiol. 2017;14(3):e14314. doi: https://doi.org/10.5812/iranjradiol.14314
Cumulative Radiation Dose and Cancer Risk Estimation in Common Diagnostic Radiology Procedures
Nikzad S, Pourkaveh M, Jabbari Vesal N, Gharekhanloo F. Cumulative Radiation Dose and Cancer Risk Estimation in Common Diagnostic Radiology Procedures. I J Radiol. 2018;15(3):e60955. doi: https://doi.org/10.5812/iranjradiol.60955
Staff radiation doses associated with nuclear procedures and efficacy of syringe shield for reduction dose
Hejazi P, Sohrabi M. Staff radiation doses associated with nuclear procedures and efficacy of syringe shield for reduction dose. koomesh. 2001;2(2):e151927. doi:
Reduction of Unwarranted Patient Exposure in X-ray Examinations
Bouzarjomehri F. Reduction of Unwarranted Patient Exposure in X-ray Examinations . I J Radiol. 2003;1(3&4):e79266. doi:
- Scopus by DOI: 0
Last Update: 3 days ago
- Scopus by Title: 0
Last Update: 3 days ago
- Scopus by Title (Ref): 0
Last Update: 3 days ago
- CrossRef: 0
Last Update: 13 hours ago
- OpenAlex: 0
Last Update: 2 days ago
- OpenCitations: 0
Last Update: 5 days ago