International Cardiovascular Research Journal
The Official Annually Journal of Cardiovascular Research Center, Shiraz University of Medical Sciences
Outline
Percutaneous Retrieval of a Dislodged Guide Wire by Dormia Basket in a 98-year-old Patient, Still a Safe and Feasible Approach
Authors
Abstract
Since the first report of percutaneous retrieval of intravascular foreign body in 1964, it has been accepted as a favorite
approach for intravascular foreign body removal. Various instruments such as snares, biopsy forceps, dormia
basket or tip deflecting wires are available for this approach. Herein, we report percutaneous retrieval of a dislodged
guide-wire by dormia basket. The Patient was a 98-year-old female who was admitted in the Intensive care unit due
to confusional state. The physian incharge left the guide-wire in her subclavian vein during central venous catheter
insertion. He realized his fault immediately, so he started anti-coagulation therapy and requested surgical consult.
Because of the patient’s high risk of surgery, the surgeon referred the patient to cardiologist for non-invasive guide
wire removal. The guide wire was apprpached through femoral vein by a dormia basket (4/6 F) and it was removed
without any difficulties or complications. Utilization of baskets for intravascular foreign body removal is frequently
reported and has been successful with low complication rates; In addition, the low cost of the device makes it less of
a burden to the patient and the hospital.
References
- 1.The references are available in PDF.
Copyright
© 2010, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.
Similar Articles
How to extract a losing intra-aortic balloon pump guide wire
Hekmat M, Ghaderi H, Mirjafari SA, Shahzamani M, Masoumi G. How to extract a losing intra-aortic balloon pump guide wire. Int J Cardiovasc Pract. 2018;3(1):e130259. doi: https://doi.org/10.21859/ijcp-03105
Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization
Amit A, Jyotsna S, Kumar Kasyap V. Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization. J Compr Ped. 2016;7(1):e33238. doi: https://doi.org/10.17795/compreped-33238
An Alternative Loop Snare Technique with Many Loops Using a Simple Guide-Wire for Removal of a Double J Stent: A Case Series
Kim SH, Choi BG, Jung Suk O, Chun HJ, Lee HG. An Alternative Loop Snare Technique with Many Loops Using a Simple Guide-Wire for Removal of a Double J Stent: A Case Series. I J Radiol. 2020;17(3):e98787. doi: https://doi.org/10.5812/iranjradiol.98787
Management of an Extremely Long Foreign Body in the Urethra and Bladder of a 13-Year-old boy: A Case Report
Rahmani MM, Shakiba B, Ameli M. Management of an Extremely Long Foreign Body in the Urethra and Bladder of a 13-Year-old boy: A Case Report. Thrita J Neu. 2013;2(3):35-37. doi: https://doi.org/10.5812/thrita.9136
Emergency CABG and Surgical Retrieval of Entrapped Coronary Stent Balloon: A Case Report
Assar O. Emergency CABG and Surgical Retrieval of Entrapped Coronary Stent Balloon: A Case Report. Multidiscip Cardio Annal. 2012;4(1):e8769. doi:
- Scopus by DOI: 0
Last Update: 1 month ago
- Scopus by Title: 0
Last Update: 1 month ago
- Scopus by Title (Ref): 0
Last Update: 1 month ago
- CrossRef: 0
Last Update: 1 day ago