Percutaneous Retrieval of a Dislodged Guide Wire by Dormia Basket in a 98-year-old Patient, Still a Safe and Feasible Approach

Authors

N Zirak1, Gh Soltani1,*, A Maraghe moghaddam2, MH Nezafati1, M Abbasi1, H Javan3
1Department of Cardiac Surgery, Iran
2Department of Cardiology, Iran
3Cardiac Surgery Research Center, Imam Reza Hospital, Mashhad University of Medical Sciences, Mashhad, Iran
*Corresponding Author: Corresponding author: Gh Soltani, Department of Cardiac Surgery, Iran Email: [email protected]

International Cardiovascular Research Journal:Vol. 4, issue 2; e65020
Published online:Jun 30, 2010
Article type:Research Article
Received:Dec 17, 2017
Accepted:Jun 30, 2010
How to Cite:Zirak N, Soltani G, Maraghe moghaddam A, Nezafati M, Abbasi M, et al. Percutaneous Retrieval of a Dislodged Guide Wire by Dormia Basket in a 98-year-old Patient, Still a Safe and Feasible Approach. Int Cardiovasc Res J. 2010;4(2):e65020. doi:

Abstract

Since the first report of percutaneous retrieval of intravascular foreign body in 1964, it has been accepted as a favorite
approach for intravascular foreign body removal. Various instruments such as snares, biopsy forceps, dormia
basket or tip deflecting wires are available for this approach. Herein, we report percutaneous retrieval of a dislodged
guide-wire by dormia basket. The Patient was a 98-year-old female who was admitted in the Intensive care unit due
to confusional state. The physian incharge left the guide-wire in her subclavian vein during central venous catheter
insertion. He realized his fault immediately, so he started anti-coagulation therapy and requested surgical consult.
Because of the patient’s high risk of surgery, the surgeon referred the patient to cardiologist for non-invasive guide
wire removal. The guide wire was apprpached through femoral vein by a dormia basket (4/6 F) and it was removed
without any difficulties or complications. Utilization of baskets for intravascular foreign body removal is frequently
reported and has been successful with low complication rates; In addition, the low cost of the device makes it less of
a burden to the patient and the hospital.

Fulltext

The full text is available in PDF.

References

  • 1.
    The references are available in PDF.

Copyright

© 2010, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

21
Jan
2018

How to extract a losing intra-aortic balloon pump guide wire

Manouchehr Hekmat,
hamid Ghaderi,
Seyedeh Adeleh Mirjafari,
Mehran Shahzamani,
Gholamreza Masoumi

Hekmat M, Ghaderi H, Mirjafari SA, Shahzamani M, Masoumi G. How to extract a losing intra-aortic balloon pump guide wire. Int J Cardiovasc Pract. 2018;3(1):e130259. doi: https://doi.org/10.21859/ijcp-03105

13
Feb
2016

Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization

Agrawal Amit,
Shrivastava Jyotsna,
Vinay Kumar Kasyap

Amit A, Jyotsna S, Kumar Kasyap V. Retention of Guidewire: A Rare but Avoidable Complication of Central Venous Catheterization. J Compr Ped. 2016;7(1):e33238. doi: https://doi.org/10.17795/compreped-33238

13
Jul
2020
An Alternative Loop Snare Technique with Many Loops Using a Simple Guide-Wire for Removal of a Double J Stent: A Case Series

An Alternative Loop Snare Technique with Many Loops Using a Simple Guide-Wire for Removal of a Double J Stent: A Case Series

Su Ho Kim,
Byung Gil Choi,
Oh Jung Suk,
Ho Jong Chun,
Hae Giu Lee

Kim SH, Choi BG, Jung Suk O, Chun HJ, Lee HG. An Alternative Loop Snare Technique with Many Loops Using a Simple Guide-Wire for Removal of a Double J Stent: A Case Series. I J Radiol. 2020;17(3):e98787. doi: https://doi.org/10.5812/iranjradiol.98787

10
Dec
2012

Management of an Extremely Long Foreign Body in the Urethra and Bladder of a 13-Year-old boy: A Case Report

Mohammad Mehdi Rahmani,
Behnam Shakiba,
Mojtaba Ameli

Rahmani MM, Shakiba B, Ameli M. Management of an Extremely Long Foreign Body in the Urethra and Bladder of a 13-Year-old boy: A Case Report. Thrita J Neu. 2013;2(3):35-37. doi: https://doi.org/10.5812/thrita.9136

12
Mar
2012

Emergency CABG and Surgical Retrieval of Entrapped Coronary Stent Balloon: A Case Report

Omid Assar

Assar O. Emergency CABG and Surgical Retrieval of Entrapped Coronary Stent Balloon: A Case Report. Multidiscip Cardio Annal. 2012;4(1):e8769. doi:

More by these authors

Gh SoltaniPubMedScholar
A Maraghe moghaddamPubMedScholar
MH NezafatiPubMedScholar
Share
Cited by
Metrics