Evaluation of the Correlation Between Myocardial Perfusion Scan Findings and Invasive Coronary Angiography Results

authors:

avatar Rahimeh Eskandarian 1 , avatar Mohammad Reza Razavi 2 , avatar Somayeh Safaei 3 , avatar Raheb Ghorbani 4 , avatar Mohammad Forozeshfard 5 , *

Department of Cardiology, Kowsar Hospital, Semnan University of Medical Sciences, Semnan, Iran
Nursing Care Research Center, Semnan University of Medical Sciences, Semnan, Iran
Clinical Research Development Unit (CRDU), Kowsar hospital, Semnan University of Medical Sciences, Semnan, Iran
Social Determinants of Health Research Center, Semnan University of Medical Sciences, Semnan, Iran
Cancer Research Center and Department of Anesthesiology, Semnan University of Medical Sciences, Semnan, Iran

how to cite: Eskandarian R, Razavi M R, Safaei S, Ghorbani R, Forozeshfard M. Evaluation of the Correlation Between Myocardial Perfusion Scan Findings and Invasive Coronary Angiography Results. Middle East J Rehabil Health Stud. 2017;4(2):e45216. https://doi.org/10.5812/mejrh.45216.

Abstract

Background:

Non-invasive and cost effective treatments of coronary artery disease (CAD) are a health priority and a current necessity.

Objectives:

This study aimed at comparing the results of myocardial perfusion imaging (MPI) with coronary angiography findings in the diagnosis of CAD.

Methods:

This cross sectional study included 155 patients with stable angina, who were referred to Kowsar hospital, Semnan, Iran, from May 2013 to April 2014. After confirmation of positive perfusion imaging, angiography was performed within 3 months. Myocardial perfusion imaging results were categorized as mild, moderate and severe, and also in coronary angiography, narrowing of more than 50% of the vessels was considered as significant stenosis.

Results:

Mean age was 58.3 ± 11.5 and 82 (52.9%) of the participants were male. According to MPI, the lateral wall of the myocardia (44.5%) was the most common affected area. Abnormal angiographic findings were reported in 47.7% (n = 74) of the patients. The number of affected vessels in the angiography had a positive correlation with the scan score (r = 0.501 and P = 0.001). The MPI had less than 50% sensitivity and more than 72% specificity.

Conclusions:

This study indicated that MPI and coronary angiography findings had a positive correlation. The sensitivity of MPI was less than optimal, and it may be better if supplemented by other diagnostic techniques for diagnosis CAD.

1. Background

Coronary artery disease (CAD) is the first leading cause of death and the third most prevalent disease in most developed and developing countries (1-3). Mortality rate has been reported as 331 per 100000 individuals/year in males and 203 in females, and this mortality rate included 35% of total mortality rate in Iran (4, 5). One person every 39 seconds or 2300 individuals per day die due to cardiovascular disease (6, 7). Moreover, in 2006, about 25 million people lived with coronary heart disease and stroke in the USA (8). However, CAD is increasing around the world due to the phenomenon of modernization, technological progress, and growing underlying risk factors (9). Hypertension and diabetes are on the rise, and have been linked with CAD occurrence. Patients with diabetes are 2 to 8 times more likely to develop cardiac events in comparison with other patients (9, 10). In addition to economic costs, CAD can lead to social and health problems (11). Therefore, many countries have adopted the policy of primary and secondary prevention and screening to identify patients at moderate and high risk (3, 12, 13). In addition to establishing the diagnosis, cardiovascular imaging plays an important role in screening and estimation of risk of CAD (14).

Cardiac catheterization and angiography is the gold standard method for diagnosis of CAD (15, 16). Angiography is used in determining the extent and severity of cardiac involvement and medical treatment policy, surgery, and invasive interventions in symptomatic patients (17). Also, practitioners use angiography to diagnose and treat patients with high risk CAD (9). However, coronary angiography is a costly procedure and Myocardial Perfusion Imaging (MPI) has been the preferred method in secondary prevention of CAD (17). Myocardial Perfusion Imaging can be applied as an alternative and appropriate diagnostic method to other non-invasive procedures (18). Also, MPI is the recommended method for determining the severity of myocardial ischemia and prognostic value for cardiovascular events and can affect the therapeutic optimal approach (19, 20). However, there is a possibility of obtaining false positive results with myocardial perfusion imaging in individuals with normal angiography (21-23). In the study of Schuijf et al., myocardial perfusion imaging compared to invasive coronary angiography had less accuracy for detecting CAD (24), while in another study by Li et al., there was no significant difference between sensitivity, specificity, and accuracy of MPI compared to Computerized Tomography (CT) coronary angiography in diagnosing CAD, and both had good diagnostic performance for CAD (25). Tamarappoo et al. showed that extent and severity of myocardial perfusion defects, measured by CT coronary angiography had a strong similarity with SPECT myocardial perfusion imaging (26).

Since the effect of CAD risk factors, including diabetes and hypertension on perfusion imaging results after compliance with angiographic findings, and also the relationship with angiographic results in terms of scoring and the affected area have not been investigated so far and most studies compared myocardial perfusion imaging with CT angiography as a noninvasive method, thus, this study aimed at comparing MPI with catheter angiography for examining coronary arteries.

2. Methods

In this study, patients with stable angina pectoris, who were referred to Kowsar hospital, Semnan (Iran) from May 2013 to April 2014, were recruited. The patients with age range of 30 to 80 years and positive MPI, confirmed by a cardiologist, were selected using convenience sampling. Also, patients with unstable angina, chronic heart failure, myocardial infarction, revascularization, aortic insufficiency, aortic stenosis, cardiomyopathy, and hypertrophic and hypertension pulmonary disease were excluded. Ethical approval was obtained for this study from the ethics committee of the Semnan University of Medical Sciences. All recruited patients provided informed written consents.

2.1. Myocardial Perfusion Imaging

All patients were examined at the nuclear medicine center of Kowsar hospital by Gated Spect myocardial perfusion imaging method on two consecutive days, applying pharmacological stress and exercise, using Siemens camera (large field LEAP) and TC99m-MIBI radiopharmaceutical apparatuses. All of the heart scans were done using the E Cam machine, manufactured by Siemens, Germany. Scans were conducted by the internal medicine assistant, in cooperation with the nuclear medicine expert from the nuclear medicine department.

2.2. Coronary Angiography

After perfusion scan, angiography was performed within 3 months. All angiographies were recorded at Kowsar hospital of Semnan city, using Germany Siemens Axiom Artis angiography apparatus with cooperation of the cardiologist.

2.3. Data Collection

Demographic and therapeutic data were collected using a questionnaire. Nuclear medicine scans were classified by the nuclear medicine specialist as involvement of the inferior, anterior, lateral and septal walls, and results were categorized as mild, moderate, and severe. Angiographic results were documented by the cardiologist and the types of coronary artery involvement included left coronary circumflex (LCX), right coronary artery (RCA), and left artery descending (LAD), and significant stenosis was considered as narrowing of the vessel lumen by more than 50% (7).

2.4. Data Analysis

The SPSS 16.0 software was used for data analysis. Descriptive statistics were used to describe data and to analyze the data; Chi-square test and Spearman and Pearson correlation coefficient were used. The sensitivity, specificity, positive, and negative predictive values were also calculated. The significance level was 5%.

3. Results

In this study, 155 patients with stable angina were enrolled in the study. The mean age of the patients was 58.3 ± 11.5 years. Minimum and maximum age was 33 and 80 years, respectively, and 82 (52.9%) individuals were male while 73 (47.1%) were female. The MPI results showed that the lateral wall (44.5%) was the most common affected wall. Also, 69% of patients had the complication in 1 wall, 25.2% in 2 walls, 5.2% in 3, and 0.6% in four walls of the heart (Table 1).

Table 1.

Distribution of Affected Areas in Perfusion Imaging

Considered SiteCountPercentage
Inferior3723.9
Anterior2012.9
Lateral6944.5
Septal3421.9
Apex5334.2
Total patients155

Angiographic results in 47.7% (n = 74) of patients were abnormal. In 35 patients (47.3%), 1 vessel, in 27 patients (36.5%) 2 vessels, and in 12 patients (16.3%) 3 vessels were affected. The most common affected vessel was related to LAD (42.6%). Among the patients, 46 males (56.1%) and 28 females (38.4%) had at least 1 of the vessels affected on angiography and this difference between the genders was statistically significant (P = 0.027). There was a significant correlation between the involvement of at least 1 vessel and age (r = 0.458 and P = 0.001). Scan results on all the walls had low sensitivity (less than 50%). There was a specificity of 80%, positive predictive value of 64%, and negative predictive value of 65%. In patients, who had anterior wall perfusion defect in their scans, 70% had an affected vessel in angiography. However, considering those who did not have a defect in their anterior wall perfusion, in 44.4% coronary involvement was observed by angiography, the difference of which was statistically significant (r = 0.413 and P = 0.028). In patients, who had septal wall perfusion defect, according to the MPI finding, 64.7% of them and also, in those who did not have septal wall perfusion defect, 43% had coronary involvement in angiography, the difference of which was statistically significant (r = 0.541 and P = 0.025) (Table 2).

Table 2.

Sensitivity, Specificity, and Positive and Negative Predictive Value of Perfusion Imaging

Scanned SitePerfusion Scan ResultAngiography ResultaP ValueSensitivitybSpecificitybPositive Predictive ValuebNegative Predictive Valueb
PositiveNegative
InferiorPositive17 (23)20 (24.7)0.80223.075.345.951.7
Negative57 (77)61 (75.3)
AnteriorPositive14 (18.9)6 (7.4)0.02818.992.670.055.6
Negative60 (81.1)75 (92.6)
LateralPositive33 (44.6)36 (44.4)0.98544.656.647.852.3
Negative41 (55.4)45 (56.6)
SeptalPositive22 (29.7)12 (14.8)0.02529.785.264.757.0
Negative52 (70.3)69 (85.2)
ApexPositive31 (41.9)22 (27.2)0.05341.972.858.557.8
Negative43 (58.1)59 (72.8)
At least 2 of the above locationsPositive34 (45.9)14 (17.3)-45.982.770.862.6
Negative40 (54.1)67 (82.7)
At least 3 or morePositive8 (10.8)1 (1.2)-10.898.888.954.8
Negative66 (89.2)80 (98.8)

Also, 38.6% of the patients with mild scan score, 87.5% of the patients with moderate scan score, and 91.7% of the patients with severe scan score had at least one affected coronary on angiography. The correlation between scan score and angiography finding was significant (r = 0.501 and P = 0.001). The Pearson correlation test showed that the correlation between the number of involved vessels in the angiography and scan score was significant (r = 0.472 and P < 0.001).

4. Discussion

This study aimed at comparing the diagnostic value of MPI and coronary angiography, the results of which showed that the sensitivity of perfusion was less than 50%, positive predictive value was 64%, specificity 80%, and negative predictive value 65%.

In a study by Wang et al. (1995), MPI with SPECT, using the radiopharmaceutical agent Tc-99m sestamibi (MIBI), was analyzed. The sensitivity and specificity of this method for the diagnosis of CAD with the degree of stenosis being 70% < (in angiography) was 95% and 75%, respectively (27). Also, the sensitivity and specificity (accuracy) of MIBI scan in patients, who had angina, and in healthy controls was the same in the diagnosis of CAD. This study showed that Tc-99m MIBI myocardial perfusion imaging for the diagnosis of CAD in elderly patients could be an alternative to coronary angiography (27).

In the study of Hannoush et al. (2003), Positive Predictive Value (PPV) for myocardial perfusion scan was 91% and negative predictive value (NPV) was 86%. Also, in this study, myocardial scintigraphy later influenced the decision to perform coronary angiography (28). Elhendy et al. (2000) showed that the sensitivity of the scan to detect significant CAD was 95% with a specificity of 55% and accuracy of 88%, and also when the defect was considered reversible, specificity was 73% (29). Johnson et al. (2001) also found 88% sensitivity and 93% specificity, when they compared myocardial perfusion scans with angiography as the gold standard method (30). In another study by Vakili et al. (1995) conducted on 59 patients, SPECT MPI and angiography were performed for all patients, and sensitivity of 90% and specificity of 80% was obtained for myocardial perfusion imaging in comparison with angiography in the diagnosis of myocardial ischemia, respectively (31). Fard-Esfehani et al. (2007) also revealed that SPECT MPI had 91.2% sensitivity and 86.6% specificity in comparison with angiography and they concluded that based on the findings of this study, the sensitivity and specificity of myocardial perfusion imaging in nuclear medicine department was acceptable and could be very efficient in the diagnosis of patients (32). Shelley et al. (2012) in India applied myocardial perfusion SPECT imaging and angiography on 99 patients and eventually 87% sensitivity and 80% specificity for MPI was obtained. In this study it was concluded that abnormal perfusion revealed the hemodynamic significance of anatomic lesions on angiography and was able to show coronary atherosclerosis before clinical symptoms indication and played a major role in the decision to angiography; also a normal perfusion scan, which has rejected a normal ischemia, cannot rule out ischemic coronary artery disease (33). Fiechter et al. (2011) obtained a sensitivity of 87% and specificity of 67% for myocardial perfusion imaging (34). In all these studies, the sensitivity and specificity of myocardial scintigraphy was estimated at a high level, representing the diagnostic value of this method. In the present study, scanning sensitivity was obtained as 30% and specificity as 80%, although the specificity was similar with other studies, yet its sensitivity was much lower than other studies. Positive and negative predictive value of perfusion scan results was the same at 65% and 64%, respectively.

One limitation of the current study was the lack of investigation of the accessory coronary branches such as diagonal and underlying conditions such as diabetes and hypertension to compare the findings with other patients. Therefore, further studies are required in this regard. The strengths of our study were selecting the patients with positive perfusion scan by SPECT MPI and the same cardiologist, who performed the SPECT MPI and invasive coronary.

4.1. Conclusions

This study showed that MPI had a low sensitivity and high specificity. Further studies are recommended to determine therapeutic advantages of MPI.

Acknowledgements

References

  • 1.

    Ali MK, Jaacks LM, Kowalski AJ, Siegel KR, Ezzati M. Noncommunicable Diseases: Three Decades Of Global Data Show A Mixture Of Increases And Decreases In Mortality Rates. Health Aff (Millwood). 2015;34(9):1444-55. [PubMed ID: 26355045]. https://doi.org/10.1377/hlthaff.2015.0570.

  • 2.

    Bhatnagar P, Wickramasinghe K, Williams J, Rayner M, Townsend N. The epidemiology of cardiovascular disease in the UK 2014. Heart. 2015;101(15):1182-9. [PubMed ID: 26041770]. https://doi.org/10.1136/heartjnl-2015-307516.

  • 3.

    Perk J, De Backer G, Gohlke H, Graham I, Reiner Z, Verschuren M, et al. European Guidelines on cardiovascular disease prevention in clinical practice (version 2012). The Fifth Joint Task Force of the European Society of Cardiology and Other Societies on Cardiovascular Disease Prevention in Clinical Practice (constituted by representatives of nine societies and by invited experts). Eur Heart J. 2012;33(13):1635-701. [PubMed ID: 22555213]. https://doi.org/10.1093/eurheartj/ehs092.

  • 4.

    Karimi-Moonaghi H, Mojalli M, Khosravan S. Psychosocial complications of coronary artery disease. Iran Red Crescent Med J. 2014;16(6). ee18162. [PubMed ID: 25068057]. https://doi.org/10.5812/ircmj.18162.

  • 5.

    Talaei M, Sarrafzadegan N, Sadeghi M, Oveisgharan S, Marshall T, Thomas GN, et al. Incidence of cardiovascular diseases in an Iranian population: the Isfahan Cohort Study. Arch Iran Med. 2013;16(3):138-44. [PubMed ID: 23432164].

  • 6.

    Davis LL, Wright JS. The Million Hearts Initiative: how nurse practitioners can help lead. J Am Acad Nurse Pract. 2012;24(10):565-8. [PubMed ID: 23006013]. https://doi.org/10.1111/j.1745-7599.2012.00774.x.

  • 7.

    Bikdeli B, Barreto-Filho JA. Reducing the cardiovascular disease burden: justified means for getting to the end. Circ Cardiovasc Qual Outcomes. 2012;5(4):580-6. [PubMed ID: 22811501]. https://doi.org/10.1161/CIRCOUTCOMES.111.964072.

  • 8.

    Rapsomaniki E, Timmis A, George J, Pujades-Rodriguez M, Shah AD, Denaxas S, et al. Blood pressure and incidence of twelve cardiovascular diseases: lifetime risks, healthy life-years lost, and age-specific associations in 1.25 million people. Lancet. 2014;383(9932):1899-911. [PubMed ID: 24881994]. https://doi.org/10.1016/S0140-6736(14)60685-1.

  • 9.

    Mann DL, Zipes DP, Libby P, Bonow RO. Braunwald's heart disease: a textbook of cardiovascular medicine. Elsevier Health Sciences; 2014.

  • 10.

    Go AS, Bauman MA, Coleman King SM, Fonarow GC, Lawrence W, Williams KA, et al. An effective approach to high blood pressure control: a science advisory from the American Heart Association, the American College of Cardiology, and the Centers for Disease Control and Prevention. J Am Coll Cardiol. 2014;63(12):1230-8. [PubMed ID: 24246165]. https://doi.org/10.1016/j.jacc.2013.11.007.

  • 11.

    Finegold JA, Asaria P, Francis DP. Mortality from ischaemic heart disease by country, region, and age: statistics from World Health Organisation and United Nations. Int J Cardiol. 2013;168(2):934-45. [PubMed ID: 23218570]. https://doi.org/10.1016/j.ijcard.2012.10.046.

  • 12.

    Muhlestein JB, Lappe DL, Lima JA, Rosen BD, May HT, Knight S, et al. Effect of screening for coronary artery disease using CT angiography on mortality and cardiac events in high-risk patients with diabetes: the FACTOR-64 randomized clinical trial. JAMA. 2014;312(21):2234-43. [PubMed ID: 25402757]. https://doi.org/10.1001/jama.2014.15825.

  • 13.

    Rabar S, Harker M, O'Flynn N, Wierzbicki AS, Guideline Development G. Lipid modification and cardiovascular risk assessment for the primary and secondary prevention of cardiovascular disease: summary of updated NICE guidance. BMJ. 2014;349:g4356. [PubMed ID: 25035388]. https://doi.org/10.1136/bmj.g4356.

  • 14.

    Valsangiacomo Buechel ER, Mertens LL. Imaging the right heart: the use of integrated multimodality imaging. Eur Heart J. 2012;33(8):949-60. [PubMed ID: 22408035]. https://doi.org/10.1093/eurheartj/ehr490.

  • 15.

    Renker M, Schoepf UJ, Wang R, Meinel FG, Rier JD, Bayer R2, et al. Comparison of diagnostic value of a novel noninvasive coronary computed tomography angiography method versus standard coronary angiography for assessing fractional flow reserve. Am J Cardiol. 2014;114(9):1303-8. [PubMed ID: 25205628]. https://doi.org/10.1016/j.amjcard.2014.07.064.

  • 16.

    Levine GN, Bates ER, Blankenship JC, Bailey SR, Bittl JA, Cercek B, et al. 2011 ACCF/AHA/SCAI Guideline for Percutaneous Coronary Intervention. A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Society for Cardiovascular Angiography and Interventions. J Am Coll Cardiol. 2011;58(24):e44-122. [PubMed ID: 22070834]. https://doi.org/10.1016/j.jacc.2011.08.007.

  • 17.

    Kasper D, Fauci A, Hauser S, Longo D, Jameson J, Loscalzo J. Harrison's Principles of internal medicine 19/E. 1 & 2. McGraw Hill Professional; 2015.

  • 18.

    Shaw LJ, Weintraub WS, Maron DJ, Hartigan PM, Hachamovitch R, Min JK, et al. Baseline stress myocardial perfusion imaging results and outcomes in patients with stable ischemic heart disease randomized to optimal medical therapy with or without percutaneous coronary intervention. Am Heart J. 2012;164(2):243-50. [PubMed ID: 22877811]. https://doi.org/10.1016/j.ahj.2012.05.018.

  • 19.

    Shaw LJ, Cerqueira MD, Brooks MM, Althouse AD, Sansing VV, Beller GA, et al. Impact of left ventricular function and the extent of ischemia and scar by stress myocardial perfusion imaging on prognosis and therapeutic risk reduction in diabetic patients with coronary artery disease: results from the Bypass Angioplasty Revascularization Investigation 2 Diabetes (BARI 2D) trial. J Nucl Cardiol. 2012;19(4):658-69. [PubMed ID: 22527794]. https://doi.org/10.1007/s12350-012-9548-3.

  • 20.

    George RT, Arbab-Zadeh A, Miller JM, Kitagawa K, Chang HJ, Bluemke DA, et al. Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia. Circ Cardiovasc Imaging. 2009;2(3):174-82. [PubMed ID: 19808590]. https://doi.org/10.1161/CIRCIMAGING.108.813766.

  • 21.

    Lee TH, Boucher CA. Clinical practice. Noninvasive tests in patients with stable coronary artery disease. N Engl J Med. 2001;344(24):1840-5. [PubMed ID: 11407346]. https://doi.org/10.1056/NEJM200106143442406.

  • 22.

    Schuijf JD, Wijns W, Jukema JW, Atsma DE, de Roos A, Lamb HJ, et al. Relationship between noninvasive coronary angiography with multi-slice computed tomography and myocardial perfusion imaging. J Am Coll Cardiol. 2006;48(12):2508-14. [PubMed ID: 17174190]. https://doi.org/10.1016/j.jacc.2006.05.080.

  • 23.

    Takx RA, Blomberg BA, El Aidi H, Habets J, de Jong PA, Nagel E, et al. Diagnostic accuracy of stress myocardial perfusion imaging compared to invasive coronary angiography with fractional flow reserve meta-analysis. Circ Cardiovasc Imaging. 2015;8(1). [PubMed ID: 25596143]. https://doi.org/10.1161/CIRCIMAGING.114.002666.

  • 24.

    Schuijf JD, van Werkhoven JM, Pundziute G, Jukema JW, Decramer I, Stokkel MP, et al. Invasive versus noninvasive evaluation of coronary artery disease. JACC Cardiovasc Imaging. 2008;1(2):190-9. [PubMed ID: 19356428]. https://doi.org/10.1016/j.jcmg.2007.12.003.

  • 25.

    Li JM, Li T, Shi RF, Zhang LR. Comparative Analysis between SPECT Myocardial Perfusion Imaging and CT Coronary Angiography for Diagnosis of Coronary Artery Disease. Int J Mol Imaging. 2012;2012:253475. [PubMed ID: 22848809]. https://doi.org/10.1155/2012/253475.

  • 26.

    Tamarappoo BK, Dey D, Nakazato R, Shmilovich H, Smith T, Cheng VY, et al. Comparison of the extent and severity of myocardial perfusion defects measured by CT coronary angiography and SPECT myocardial perfusion imaging. JACC Cardiovasc Imaging. 2010;3(10):1010-9. [PubMed ID: 20947046]. https://doi.org/10.1016/j.jcmg.2010.07.011.

  • 27.

    Wang F, Amanullah A, Kiat H, Friedman J, Berman D. Diagnostic efficacy of stress technetium 99m-labeled sestamibi myocardial perfusion single-photon emission computed tomography in detection of coronary artery disease among patients over age 80*. J Nucl Cardiol. 1995;2(5):380-8. https://doi.org/10.1016/s1071-3581(05)80025-x.

  • 28.

    Hannoush H, Shaar K, Alam S, Nasrallah A, Sawaya J, Dakik HA. Analysis of referral patterns, predictive accuracy, and impact on patient management of myocardial perfusion imaging in a new nuclear cardiology laboratory. J Nucl Cardiol. 2003;10(2):148-53. [PubMed ID: 12673179]. https://doi.org/10.1067/mnc.2003.397.

  • 29.

    Elhendy A, Sozzi FB, van Domburg RT, Bax JJ, Geleijnse ML, Valkema R, et al. Accuracy of exercise stress technetium 99m sestamibi SPECT imaging in the evaluation of the extent and location of coronary artery disease in patients with an earlier myocardial infarction. J Nucl Cardiol. 2000;7(5):432-8. [PubMed ID: 11083191]. https://doi.org/10.1067/mnc.2000.107426.

  • 30.

    Johansen AH, Poulsen TS, Hoilund-Carlsen PF, Thayssen P, Gaster AL, Veje A, et al. Myocardial perfusion imaging and coronary angiography in patients with known or suspected stable angina pectoris. Dan Med Bull. 2001;48(2):80-3. [PubMed ID: 11414123].

  • 31.

    Vakili A. Comparative study for myocardial perfusion imaging by SPECT and coronary angiography. Iran J Nucl Med. 1996;6:8-11.

  • 32.

    Fard-Esfahani A, Fallahi B, Saghari M, Eftekhari M, Beiki D. Myocardial perfusion scan accuracy in detection of coronary artery disease-comparison with exercise stress test [In Persian]. Iran J Nucl Med. 2007;15:16-23.

  • 33.

    Shelley S, Indirani M, Sathyamurthy I, Subramanian K, Priti N, Harshad K, et al. Correlation of myocardial perfusion SPECT with invasive and computed tomography coronary angiogram. Indian Heart J. 2012;64(1):43-9. [PubMed ID: 22572425]. https://doi.org/10.1016/S0019-4832(12)60010-8.

  • 34.

    Fiechter M, Ghadri JR, Kuest SM, Pazhenkottil AP, Wolfrum M, Nkoulou RN, et al. Nuclear myocardial perfusion imaging with a novel cadmium-zinc-telluride detector SPECT/CT device: first validation versus invasive coronary angiography. Eur J Nucl Med Mol Imaging. 2011;38(11):2025-30. [PubMed ID: 21761267]. https://doi.org/10.1007/s00259-011-1877-y.