Fluorimetry as a Simple and Sensitive Method for Determination of Catalase Activity

Authors

Saeed Naazeri1, Mosayeb Rostamian2, Bahram Yaghmaei3, Mehdi Hedayati4,*
1Department of Clinical Biochemistry, Faculty of Medicine, Shahid Beheshti Univer sity of Medical Sciences, Tehran, Iran
2Biotechnology and Biochemistry Departments, Pasteur institute of Iran , Tehran, Iran
3Department of Clinical Biochemistry, Faculty of Medicine, Shahid Beheshti Univer sity of Medical Sciences , Tehran, Iran
4Cellular & Molecular Endocrine Research Center Research Institute for Endocrine Sciences Shahid Beheshti University of Medical Science, Tehran, Iran
*Corresponding Author: Cellular & Molecular Endocrine Research Center Research Institute for Endocrine Sciences Shahid Beheshti University of Medical Science, Tehran, Iran Email: [email protected]

Zahedan Journal of Research in Medical Sciences:Vol. 16, issue 2; 64-67
Published online:Jun 29, 2013
Article type:Research Article
Received:Jul 12, 2012
Accepted:Oct 10, 2012
How to Cite:Naazeri S, Rostamian M, Yaghmaei B, Hedayati M. Fluorimetry as a Simple and Sensitive Method for Determination of Catalase Activity. Zahedan J Res Med Sci. 2014;16(2):. doi:

Abstract

Background: Catalase enzyme plays an important role in the anti-oxidation defense of body so it is important to measure its activity. Nowadays catalase activity measurement is performed by expensive imported kits in various scientific fields. The purpose of this study was to design a sensitive fluorimetry method for measuring catalase activity with improved sensitivity, accuracy and speed.

Materials and Methods: In this study, the reaction of hydrogen peroxide with peroxidase (as a reaction accelerator) was used in fluorimetry for catalase activity measuring in serum samples in order to increase the sensitivity of the assay. The sensitivity and intra- and inter-assay accuracy, verification test, recovery and parallelism tests, comparison method and correlation and coherence investigation methods were also performed. In order to increase the accuracy and speed of reading, the assay was performed in microplates and reading was done in fluorimetry plates.

Results: The percentage of intra- and inter-assay variation coefficients were measured 3.8-6.6 % and 4.1-7.3%, respectively. Comparison of the results of mentioned method for 50 serum samples with common colorimetric method showed a good correlation (0.917). In assessing the accuracy, the recovery percent was obtained 91% to 107%. The test sensitivity was measured 0.02 IU/ml.

Conclusion: The fluorimetry method by microplate reading has a sufficient precision, accuracy and efficiency for catalase activity measuring as well as speed of measurement. Thus it can be an alternative method to conventional imported colorimetric methods.

Highlights

KeywordsFluorimetry

Fulltext

Fulltext is availale in the PDF.

References

  • 1.
    References are available in the PDF.

Copyright

© 2014, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

31
Jan
2016

A Peroxidase-linked Spectrophotometric Assay for the Detection of Monoamine Oxidase Inhibitors

Kangkang Zhi,
Zhongduo Yang,
Jie Sheng,
Zongmei Shu,
Yin Shi

Zhi K, Yang Z, Sheng J, Shu Z, Shi Y. A Peroxidase-linked Spectrophotometric Assay for the Detection of Monoamine Oxidase Inhibitors. Iran J Pharm Res. 2016;15(1):e125084. doi: https://doi.org/10.22037/ijpr.2016.1782

17
Jan
2017

A Spectrophotometric Method for the Determination of Aldehyde Oxidase Activity Using 3-Methyl-2- Benzothiazolinone Hydrazine: A Preliminary Study

Maryam Siah,
Mohammad Hossein Farzaei,
Mohammad Reza Ashrafi-Kooshk,
Hadi Adibi,
Reza Khodarahmi

Siah M, Farzaei MH, Ashrafi-Kooshk MR, Adibi H, Khodarahmi R. A Spectrophotometric Method for the Determination of Aldehyde Oxidase Activity Using 3-Methyl-2- Benzothiazolinone Hydrazine: A Preliminary Study. J Rep Pharm Sci. 2017;6(1):e147619. doi:

20
Nov
2010

Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase

Mohammad Hossein Sorouraddin,
Ebrahim Fooladi,
Abdolhossein Naseri,
Mohammad-Reza Rashidi

Sorouraddin MH, Fooladi E, Naseri A, Rashidi M. Development of a Sensitive Spectrofluorometric-Multivariate Calibration Method for Enzyme Kinetic of Aldehyde Oxidase. Iran J Pharm Res. 2022;8(3):e128634. doi: https://doi.org/10.22037/ijpr.2010.807

28
Sep
2014

Side effects of aspirin on the structure and function of liver catalase

Bahare Koohshekan,
Adeleh Divsalar,
Maryam Saeidifar,
Ali Akbar Saboury

Koohshekan B, Divsalar A, Saeidifar M, Saboury AA. Side effects of aspirin on the structure and function of liver catalase. koomesh. 2014;16(1):e151286. doi:

21
Feb
2015

Analytical Utility of Potassium Permanganate for the Assay of Albendazole in Bulk Drug and Pharmaceuticals

Nagaraju Swamy,
Kudige Nagaraj Prashanth,
Kanakapura Basavaiah

Swamy N, Prashanth KN, Basavaiah K. Analytical Utility of Potassium Permanganate for the Assay of Albendazole in Bulk Drug and Pharmaceuticals. J Rep Pharm Sci. 2015;4(1):e147685. doi:

More by these authors

Saeed NaazeriPubMedScholar
Mosayeb RostamianPubMedScholar
Bahram YaghmaeiPubMedScholar
Mehdi HedayatiPubMedScholar
Share
Cited by
Metrics