Institutional review board approval was granted and all patients gave informed consent. The study group comprised 74 patients with clinically suspected acute PE consecutively. All had undergone clinical assessment of the probability of PE, using the original Wells scoring system. All patients with a suspicion of PE and high serum D-dimer levels underwent both CT pulmonary angiography (CTPA) and bilateral lower extremity venous duplex ultrasonography (DUS) within 24 hours of admission to the hospital.
The patients were divided into three groups;.35 patients had negative CTPA and deep vein thrombosis (DVT) findings (group 1), 29 had positive CTPA and negative DVT findings of PE (group 2), and 10 patients had positive DVT and CTPA findings (group 3).
Two radiologists who were blinded to each other’s findings reviewed the CTPA and bilateral lower extremity venous DUS results.
Measurements of the serum D-dimer were made using a Sysmex CA 7000 with D-dimer plus reagent and D-dimer plus activator (Dade Behring Marburg, Germany) solutions.
CTPA was performed on a 16-slice CT scanner (LightSpeed Plus, General Electric Medical Systems, Milwaukee, USA) with electrocardiogram (ECG)-gating with 0.5-second helical rotation time, 1.25 mm collimation. One hundred 100 mL of Iopamidol (Isovue 370, Bracco Diagnostics) was injected at a rate of 4 mL/sec. Imaging began 20 seconds after initiation of the contrast infusion.
The CTPA findings were accepted as positive if thrombus, a partial or complete filling defect was present in one or more pulmonary arteries, or a sharp arterial cut-off within an opacified artery.
The method of Qanadli et al. was used to evaluate the degree of pulmonary vascular obstruction. It was considered that the arterial tree of each lung had 10 segmental arteries (three in the upper lobes, two in the middle lobe and in the lingula and five in the lower lobes). The presence of emboli in a segmental artery was evaluated 1 point. The emboli in the most proximal arterial level were classified with a value equal to the number of segmental arteries that rose distally. For each value, a weighting factor was assigned, based on the degree of vascular obstruction. This factor was equal to zero, when no thrombus was observed; 1, when partially occlusive thrombus or 2 was observed, with total occlusion (
2).
Quantitative measurements of cardiac CT were obtained in axial CT images:, right ventricle (RV) and left ventricle (LV) diameter, RV wall thickness (RVW)/LV wall thickness (LVW), the thickness of the interventricular septum and the diameter of the left and right pulmonary artery, the diameter of the azygos vein, the return flow of the contrast agent in the inferior vena cava (IVC), and the inclination of the septum to the left, leading to the assessment of right heart failure. Ventricular axis was measured in diastole on a single transverse scan perpendicular to the long axis of the heart and was defined as the largest distance between the inner aspect of the interventricular septum and the free wall of the ventricle. Measurements were taken of the portion of the azygos vein facing the right tracheal wall, and of the superior vena cava at the level of the azygos arch.
Inclination of the septum (convex toward the left ventricle) was accepted as septal bowing. Trace of contrast reflux to IVC with or without reflux to hepatic veins was accepted as IVC reflux.
The lower extremity Doppler ultrasound (DUS) was performed using a Logic 700 (General Electric Medical Systems, Milwaukee, USA) with a linear 7-MHz probe and a 3.5-mm convex probe from the IVC distal segment to the level of trifurcation. Sonographic findings were considered positive if thrombus, complete or partial filling defect was present, or lack of Doppler flow at examination. The method of Mewissen et al. was used to evaluate the burden of blood clots. Seven venous segments are included: IVC, common iliac veins, external iliac veins, common femoral veins, superficial proximal femoral veins, distal superficial femoral veins and popliteal veins. The score is based on partial or complete occlusion of each segment (0 - 2). The maximum score is 14 per extremity (
3).
All statistical analyses were performed using the statistical package for social sciences (IBM SPSS Statistics 22.0) software program. Continuous variables were compared using Student’s t-test, nominal variables were scored using the chi-square test and Spearman’s correlation test. In addition, one-way analysis of variance (ANOVA) and correlation tests were used. All values given are mean ± standard deviation (SD) of the mean (SEM). P < 0.05 was accepted as statistical significance.