Cover image of the article: Evaluation of an arterial blood sampling device and its function in accelerating and facilitating blood sampling

Image Credit:J Cell Mol Anesth

Evaluation of an arterial blood sampling device and its function in accelerating and facilitating blood sampling

Authors

Ghasem Soltani1,*, Arash Peivandi2, Maliheh ZiaeeMaliheh Ziaee ORCID3, Alireza Hoseini4, Mahmood Khorsand5, Farzaneh Farrokhseir6, seyed javad purafzali firuzabadiseyed javad purafzali firuzabadi ORCID7
1MD. Professor of Anesthesiology, Lung Diseases Research Center , Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad,
2MD. Associate Prof. of Anesthesiology, Lung Diseases Research Center, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad,
3MD. Assistant Professor of Community Medicine, Department of Community Medicine, School of Medicine, Social Determinants of Health Research Center, Gonabad University of Medical Sciences, Gonabad,
4MD. Internist , Lung Diseases Research Center Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad,
5MD. Fellowship of Critical care Medicine, Student Research Committee, Department of Anesthesiology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad,
6MD. Resident of Anesthesiology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran.
7MD. Resident of Anesthesiology and Critical Care, Student Research Committee, Department of Anesthesiology, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad,
*Corresponding Author: MD. Professor of Anesthesiology, Lung Diseases Research Center , Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Email: soltanigh@mums.ac.ir

Journal of Cellular & Molecular Anesthesia:Vol. 4, issue 2; e149578
Published online:Oct 29, 2019
Article type:Original Articles
How to Cite:Soltani G, Peivandi A, Ziaee M, Hoseini A, Khorsand M, et al. Evaluation of an arterial blood sampling device and its function in accelerating and facilitating blood sampling. J Cell Mol Anesth. 2019;4(2):e149578. doi: https://doi.org/10.22037/jcma.v4i2.26376

Abstract

Background: Arterial blood sampling is among the basic standards in critically ill patients. The aim of this study was to examine an inventive sampling device in facilitating arterial blood sampling in comparison to the conventional method using an insulin syringe.Methods and materials: This randomized interventional clinical trial was performed on 100 patients admitted to Qaem and Imam Reza Hospitals in Mashhad in 2016 for whom two arterial blood gas (ABG) samples were indicated. The patients were randomly selected by the visiting operator on a daily basis. The operator visited the hospital on certain days and took two samples from the selected patients.Results: The patients' mean age was 45.31?16.15 years. In the insulin syringe group, venous blood gas sampling was in 24% and arterial sample in 76%. In the designed device group, same figures were 12.1% and 87.9%, respectively. Sampling score (p=0.01), unsuccessful attempts with and without needle removal from the skin (p=0.01), and need for vertical and horizontal needle displacement for sampling (p=0.01) were significantly differed between the two groups. Localized swelling score and its size, localized bruising, palpable arterial spasm and the spasm duration was significantly less for the inventive device (p<0.05). Satisfaction score of patients and operator were significantly higher in the device group (p=0.01).Conclusion: The study device had desirable function in facilitating and accelerating arterial blood sampling. Its application can be further approved by future studies.Keywords: Arterial blood sampling, Facilitated sampling, Accelerated sampling, Intensive Care Unit

Highlights

References

  • 1.
    References are in the PDF file of the article.

Copyright

© 2019, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

21
Jun
2016
Comparison of the effect of direct venipuncture and venous catheter blood sampling methods on the biochemical results of patients hospitalized in CCU

Comparison of the effect of direct venipuncture and venous catheter blood sampling methods on the biochemical results of patients hospitalized in CCU

Zahra Pishkar Mofrad,
Shahla Shafiee,
Nasrin Mahmoodi,
Mojhde Jahantigh,
Hamideh Samadzadeh

Pishkar Mofrad Z, Shafiee S, Mahmoodi N, Jahantigh M, Samadzadeh H. Comparison of the effect of direct venipuncture and venous catheter blood sampling methods on the biochemical results of patients hospitalized in CCU. Med Surg Nurs J. 2016;5(1):e68067. doi:

23
Jun
2018
The Relationship between Arterial and Central Venous Blood Gases Values in Patients Undergoing Mechanical Ventilation after Cardiac Surgery

The Relationship between Arterial and Central Venous Blood Gases Values in Patients Undergoing Mechanical Ventilation after Cardiac Surgery

Mohammadamin Valizad Hassanloei,
Alireza Mahoori,
Nazli Karami,
Venus Sina

Valizad Hassanloei M, Mahoori A, Karami N, Sina V. The Relationship between Arterial and Central Venous Blood Gases Values in Patients Undergoing Mechanical Ventilation after Cardiac Surgery. Anesth Pain Med. 2018;8(3):e74243. doi: https://doi.org/10.5812/aapm.74243

7
May
2019
Effect of planned visiting policy on physiological indices of intensive care unit patients

Effect of planned visiting policy on physiological indices of intensive care unit patients

Reihane Akbari,
Hossein Karimi Moonaghi,
Seyedreza Mazloum,
Ahmad Bagheri Moghaddam

Akbari R, Karimi Moonaghi H, Mazloum S, Bagheri Moghaddam A. Effect of planned visiting policy on physiological indices of intensive care unit patients. koomesh. 2019;21(2):e153081. doi:

31
May
2026
The Effect of Implementing a Daily Awakening Protocol on Treatment Outcomes of Mechanically Ventilated Patients Hospitalized in the Intensive Care Unit: A Randomized Clinical Trial Study

The Effect of Implementing a Daily Awakening Protocol on Treatment Outcomes of Mechanically Ventilated Patients Hospitalized in the Intensive Care Unit: A Randomized Clinical Trial Study

Fereshteh Amiri,
Mohammad Adineh,
Parisa Eskandari,
Saeed Ghanbari

Amiri F, Adineh M, Eskandari P, Ghanbari S. The Effect of Implementing a Daily Awakening Protocol on Treatment Outcomes of Mechanically Ventilated Patients Hospitalized in the Intensive Care Unit: A Randomized Clinical Trial Study. Jundishapur J Nat Pharm Prod. 2026;21(2):e172262. doi: https://doi.org/10.5812/jjnpp-172262

1
Sep
2020
Evaluation of the Efficiency of Indirect Blood Pressure Measurement Methods in Comparison to Intra-Arterial Reading among Iranian Individuals

Evaluation of the Efficiency of Indirect Blood Pressure Measurement Methods in Comparison to Intra-Arterial Reading among Iranian Individuals

Mahmood Emami,
Davood Shafie,
Mehrbod Vakhshoori,
Maryam Eghbali-Babadi,
Elham Ahmadipour,
Alireza Khosravi

Emami M, Shafie D, Vakhshoori M, Eghbali-Babadi M, Ahmadipour E, et al. Evaluation of the Efficiency of Indirect Blood Pressure Measurement Methods in Comparison to Intra-Arterial Reading among Iranian Individuals. Int Cardiovasc Res J. 2020;14(3):e103852. doi:

More by these authors

Ghasem SoltaniPubMedScholar
Arash PeivandiPubMedScholar
Maliheh ZiaeePubMedScholar
Alireza HoseiniPubMedScholar
Mahmood KhorsandPubMedScholar
Farzaneh FarrokhseirPubMedScholar
seyed javad purafzali firuzabadiPubMedScholar
Share
Cited by
Metrics