Materials
Chitosan (molecular weight, 100 kDa; deacetylation degree, 87.7%) was kindly supplied from Jakwang (Ansung, Korea). Branched PEI 25K was obtained from Sigma-Aldrich (St. Louis, MO, USA). Branched PEI 1800 Da was purchased from Wako (Osaka, Japan). pcDNA3.1-GFP was purchased from Invitrogen (Carlsbad, CA, USA). The plasmids were propagated in E. coli, extracted by the alkalilysis technique, and purified by QIAGEN kit (Chatsworth, CA, USA).
Aerosol gene delivery system
The nose-only exposure chamber (NOEC) system consists of dual cylindrical box and 4 small tubes (
Figure 1).
Schematic diagram of aerosol gene delivery devices. HEPA filter: High-Efficiency Particulate Air filter. MFC: Mass Flow Controller.
Conical acrylic tubes were connected to the main chamber and mice (male C57BL/6, 8~10 wks old, SLC, Hamaguchi, Japan) were placed in the tubes. All animal experiments were performed in accordance with the guidelines of Seoul National University for the care and use of animals. Nebulizer (Dusturbo, Seoul, Korea)-generated aerosols were entered into the NOEC. Operation of the aerosol generation process by nebulizer was as follows: air flow rate was 2 L/min (lpm) by a mass flow controller (MFC, Brooks Instruments, Hatfield, PA, USA) and the complex was composed of plasmid DNA; 200 μg and polymer (PEI 25K; 260 μg, N/P ratio of 10 and CHI-g-PEI; 1,400 μg, N/P ratio of 35) was added to 20 mL deionized water. Aerosol size distributions were measured with a dust monitor (Grimm Aerosol Technik, Germany). Size distribution measurements were taken in the NOEC.
Transfection efficiency
To determine the efficiency of gene transfection, animals were exposed to aerosol containing GFP-PEI and GFP-Chi-g-PEI complex for 30 min in NOEC system. Animals were sacrificed 48 h after the inhalation and routinely fixed lungs were cryosectioned for confocal laser scanning microscopy (CLSM, Carl Zeiss-LSM510, Germany). CLSM images were quantified and analyzed by a computerized system (Media Cyber-netics, Silver Spring, MD, USA).
Pulmonary toxicity analysis
For the assessment of pulmonary toxicity of CHI-g-PEI and PEI, mice were exposed to aerosols, two times in a week for a total of 4 weeks. The control group was exposed to air filtered by a high-efficiency particulate air (HEPA) filter and polymer groups were exposed to aerosol containing PEI; 260 μg and CHI-g-PEI; 1,400 μg without DNA in distilled water, respectively. At the end of exposure, bronchioalveolar lavage (BAL) fluid from mice was obtained by whole-lung lavage. As a marker of cellular damage, lactate acid dehydrogenase (LDH) activity in BAL fluid was measured using an automated biochemical analyzer (VITALAB, Merck, the Netherlands).
Histopathological examination
For histopathological analysis, lungs were removed from each animal. The organs were immersion-fixed in 10% neutral buffered formalin. After routine tissue processing, the tissues were embedded in paraffin and the tissue sections (5 μm) were then prepared for hematoxylin and eosin (H&E) and Periodic acid-Schiff (PAS) stain. The slides were evaluated under light microscopy.
Statistical analysis
All results are expressed as mean ± standard error. A multiple variance of a Student’s t-test (Graphpad Software, San Diego, CA, USA) was used to compare the test groups with those obtained from unexposed control group. The level of significance was set at p < 0.05 and p < 0.01.