Comparison of Low Dose and Standard Dose Abdominal CT Scan in Body Stuffers

Authors

Zahra Mahboubifooladi1,*, Hooman Bahramimotlagh1
1Shahid Beheshti University of Medical Sciences, Tehran, Iran
*Corresponding Author: Shahid Beheshti University of Medical Sciences, Tehran, Iran, mahboubiz@yahoo.com. Email: mahboubiz@yahoo.com

Iranian Journal of Radiology:Vol. 14, issue Special Issue; e47966
Published online:Apr 12, 2017
Article type:Abstract
Received:Dec 20, 2016
Accepted:Feb 07, 2017
How to Cite:Mahboubifooladi Z, Bahramimotlagh H. Comparison of Low Dose and Standard Dose Abdominal CT Scan in Body Stuffers. I J Radiol. 2017;14(Special Issue):e47966. doi: https://doi.org/10.5812/iranjradiol.47966

Abstract

Background:

Body stuffer determination is an important concern in emergency departments for referred patients with suspicion of swallowing drug packets. Because of small packet size, plain radiography is of little value in most patients. On the other hand, abdominal and pelvic CT scan is burdened by high cost and radiation dose. This study was performed to evaluate the sensitivity of low-dose CT scan in comparison with conventional one. So, the former can be used as an alternative screening and follow up tool for suspected body stuffers

Methods:

In this prospective study, suspected body stuffers who were referred to radiology department, underwent two different protocols of abdominal and pelvic non-contrast CT scan: low-dose (equivalent dose of conventional abdominal x-ray) and standard dose. Standard dose CT scan was considered as the gold standard and low-dose protocol was compared with that for image quality and packet detection rate.

Results:

The study consisted of 40 patients (all men, with mean age of 33.38 7.4 years). CT evaluation with standard dose were positive in 22 patients (55%). Only 1 (2.5%) CT scan assigned as unacceptable by each radiologist in low-dose group. Noise average of low-dose protocol, was approximately 7 times greater than standard dose group, while DLP and ED are 9.7 times smaller. In comparison with standard dose CT scan, low-dose group had a sensitivity of 86.46%, specificity of 100%, PPV and NPV of 100% and 85.71%.

Discussion:

Accuracy of low-dose CT scan for detection of baggies larger than 1 cm, approaches 100%. Therefore, it looks an appropriate screening method for body stuffers, especially when the packages are larger.

Highlights

Full Text

Full text is available in PDF

Copyright

© 2017, Author(s). This open-access article is available under the Creative Commons Attribution 4.0 (CC BY 4.0) International License (https://creativecommons.org/licenses/by/4.0/), which allows for unrestricted use, distribution, and reproduction in any medium, provided that the original work is properly cited.

Similar Articles

12
Apr
2017

How Low Can We Go Dose Saving Through Low-Dose Examination for Urolithiasis Via Modern Computer Tomography with Tinfilter

Youssef Erfanian,
Nika Guberina,
Saravanabavaan Suntharalingam,
Jens Theysohn

Erfanian Y, Guberina N, Suntharalingam S, Theysohn J. How Low Can We Go Dose Saving Through Low-Dose Examination for Urolithiasis Via Modern Computer Tomography with Tinfilter. I J Radiol. 2017;14(Special Issue):e48020. doi: https://doi.org/10.5812/iranjradiol.48020

28
Feb
2014

Usefulness of Lung Window in Evaluating Abdominal Computed Tomography of Drug Mules

Fatemeh Vakilian,
Makhtoom Shahnazi,
Hooman Bahrami-Motlagh,
Hossein Hassanian Moghaddam

Vakilian F, Shahnazi M, Bahrami-Motlagh H, Moghaddam HH. Usefulness of Lung Window in Evaluating Abdominal Computed Tomography of Drug Mules. I J Radiol. 2014;11(30th Iranian Congress of Radiology):e21281. doi: https://doi.org/10.5812/iranjradiol.21281

26
Apr
2023
A Study of Fixed Current and Automatic Tube Current Modulation at a Fixed Low Tube Voltage in Low-dose Computed Tomography (CT) Imaging of Infant Lungs

A Study of Fixed Current and Automatic Tube Current Modulation at a Fixed Low Tube Voltage in Low-dose Computed Tomography (CT) Imaging of Infant Lungs

Wushuang Chen,
Shilong Tang,
Zhen Xu,
Xin Chen,
Yinglan Zheng,
Ling He

Chen W, Tang S, Xu Z, Chen X, Zheng Y, et al. A Study of Fixed Current and Automatic Tube Current Modulation at a Fixed Low Tube Voltage in Low-dose Computed Tomography (CT) Imaging of Infant Lungs. I J Radiol. 2023;20(2):e126362. doi: https://doi.org/10.5812/iranjradiol-126362

11
Oct
2020
Performance of Low-Dose Chest CT Scan for Initial Triage of COVID-19

Performance of Low-Dose Chest CT Scan for Initial Triage of COVID-19

Hooman Bahrami-Motlagh,
Sahar Abbasi,
Maryam Haghighimorad,
Babak Salevatipour,
Ilad Alavi Darazam,
Morteza Sanei Taheri
,et al.

Bahrami-Motlagh H, Abbasi S, Haghighimorad M, Salevatipour B, Alavi Darazam I, et al. Performance of Low-Dose Chest CT Scan for Initial Triage of COVID-19. I J Radiol. 2020;17(4):e104950. doi: https://doi.org/10.5812/iranjradiol.104950

28
Apr
2020
Use of Low-dose Chest CT Scan in the Evaluation of Breast Composition According to the Recommendations of BI-RADS Atlas-Fifth Edition

Use of Low-dose Chest CT Scan in the Evaluation of Breast Composition According to the Recommendations of BI-RADS Atlas-Fifth Edition

Feng Ao,
Xueguo Liu,
Mingzhu Liang,
Jiebing Gao

Ao F, Liu X, Liang M, Gao J. Use of Low-dose Chest CT Scan in the Evaluation of Breast Composition According to the Recommendations of BI-RADS Atlas-Fifth Edition. I J Radiol. 2020;17(2):e96718. doi: https://doi.org/10.5812/iranjradiol.96718

More by these authors

Zahra MahboubifooladiPubMedScholar
Hooman BahramimotlaghPubMedScholar
Share
Cited by
Metrics